COMPONENT DESCRIPTIONNJEC0504S02EGR Volume Control ValveNJEC0504S0201The EGR volume control valve uses a step motor to control the flow
rate of EGR from exhaust manifold. This motor has four w

Page 1083 of 2898

NISSAN ALMERA 2001  Service Manual SEF184UD
On Board Diagnosis LogicNJEC0240The ECM monitors the switching frequency ratio of heated oxygen
sensors 1 (front) and 2 (rear).
A three way catalyst with high oxygen storage capacity will ind

Page 1084 of 2898

NISSAN ALMERA 2001  Service Manual SEF074X
Overall Function CheckNJEC0242Use this procedure to check the overall function of the three way
catalyst. During this check, a 1st trip DTC might not be confirmed.
Without CONSULT-II
1) Start

Page 1085 of 2898

NISSAN ALMERA 2001  Service Manual 2 CHECK EXHAUST AIR LEAK
1. Start engine and run it at idle.
2. Listen for an exhaust air leak before the three way catalyst.
SEF099P
OK or NG
OK©GO TO 3.
NG©Repair or replace.
3 CHECK INTAKE AIR LE

Page 1086 of 2898

NISSAN ALMERA 2001  Service Manual 5 CHECK INJECTORS
1. Refer to Wiring Diagram for Injectors, EC-542.
2. Stop engine and then turn ignition switch ªONº.
3. Check voltage between ECM terminals 101, 103, 105 and 107 and ground with CO

Page 1089 of 2898

NISSAN ALMERA 2001  Service Manual ECM Terminals and Reference Value=NJEC0250Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/outpu

Page 1092 of 2898

NISSAN ALMERA 2001  Service Manual Diagnostic ProcedureNJEC0254
1 CHECK POWER SUPPLY
1. Turn ignition switch ªOFFº.
2. Disconnect EVAP canister purge volume control solenoid valve harness connector.
SEF076X
3. Turn ignition switch ª

Page 1093 of 2898

NISSAN ALMERA 2001  Service Manual 4 CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Refer to ªComponent Inspectionº EC-369.
OK or NG
OK©GO TO 5.
NG©Replace EVAP canister purge volume control solenoid valve.
5 CHECK INTERMI