2001 INFINITI QX4 ignition

[x] Cancel search: ignition

Page 920 of 2395

INFINITI QX4 2001  Factory Service Manual Diagnostic ProcedureNBEC0241
1 CHECK RUBBER TUBE
1. Turn ignition switch ªOFFº.
2. Check rubber tube connected to the EVAP control system pressure sensor for clogging, vent, kink, disconnection or
i

Page 921 of 2395

INFINITI QX4 2001  Factory Service Manual 4 CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
1. Turn ignition switch ªONº.
2. Check voltage between EVAP control system pressure sensor terminal 3 and ground with CONSULT-II or t

Page 926 of 2395

INFINITI QX4 2001  Factory Service Manual 16 CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
1. Remove EVAP control system pressure sensor with its harness connector connected.
CAUTION:
INever apply force to the air hole protector of the sensor if

Page 931 of 2395

INFINITI QX4 2001  Factory Service Manual SEF565X
DTC Confirmation ProcedureNBEC0646
SEF566X
SEF874X
SEF567X
CAUTION:
Never remove fuel filler cap during the DTC Confirmation Pro-
cedure.
NOTE:
IIf DTC P0455 is displayed with P1448, perform t

Page 932 of 2395

INFINITI QX4 2001  Factory Service Manual 8) Stop vehicle.
9) Select ªMODE 3º with GST.
IIf P0455 is displayed on the screen, go to ªDiagnostic
Procedureº, EC-397.
IIf P0440 or P1440 is displayed on the screen, go to ªDiagnos-
tic Proced

Page 935 of 2395

INFINITI QX4 2001  Factory Service Manual 9 CHECK FOR EVAP LEAK
With CONSULT-II
1. Turn ignition switch ªONº.
2. Select ªEVAP SYSTEM CLOSEº of ªWORK SUPPORTº mode with CONSULT-II.
3. Touch ªSTARTº and apply pressure into the EVAP line

Page 936 of 2395

INFINITI QX4 2001  Factory Service Manual 10 CHECK FOR EVAP LEAK
Without CONSULT-II
1. Turn ignition switch ªOFFº.
2. Apply 12 volts DC to EVAP canister vent control valve. The valve will close. (Continue to apply 12 volts until the end of

Page 940 of 2395

INFINITI QX4 2001  Factory Service Manual 16 CHECK ABSOLUTE PRESSURE SENSOR
1. Remove absolute pressure sensor with its harness connector connected.
SEF961Y
2. Remove hose from absolute pressure sensor.
3. Install a vacuum pump to absolute pr