2001 INFINITI QX4 IDX

[x] Cancel search: IDX

Page 2100 of 2395

INFINITI QX4 2001  Factory Service Manual Preparation
SPECIAL SERVICE TOOLS=NBRS0008The actual shapes of Kent-Moore tools may differ from those of special service tools illustrated here.
Tool number
(Kent-Moore No.)
Tool nameDescription
KV991

Page 2102 of 2395

INFINITI QX4 2001  Factory Service Manual load limiter permits the specified extension of the seat belt by the
twisting of the ELR shaft, and a relaxation of the chest-area seat
belt web tension while maintaining force.
SRS560
Built-in Type S

Page 2104 of 2395

INFINITI QX4 2001  Factory Service Manual Diagnosis Sensor Unit
REMOVAL AND INSTALLATIONNBRS0012CAUTION:
IBefore servicing SRS, turn the ignition switch off, discon-
nect both battery cables and wait for at least 3 minutes.
IThe special bolts

Page 2106 of 2395

INFINITI QX4 2001  Factory Service Manual Driver Air Bag Module and Spiral Cable
REMOVAL AND INSTALLATIONNBRS0013
SRS782-A
SBF811E
REMOVALNBRS0014CAUTION:
IBefore servicing SRS, turn the ignition switch off, discon-
nect both battery cables a

Page 2108 of 2395

INFINITI QX4 2001  Factory Service Manual SBF812EH
8. Position air bag module and tighten with new special bolts.
9. Connect air bag module connector.
10. Install steering switches and lids.
11. Conduct self-diagnosis to ensure entire SRS ope

Page 2110 of 2395

INFINITI QX4 2001  Factory Service Manual SRS162
4. Install instrument lower panel on passenger side.
5. Connect air bag module connector to air bag harness connec-
tor.
6. Install glove box assembly.
7. Connect both battery cables.
8. Conduc

Page 2112 of 2395

INFINITI QX4 2001  Factory Service Manual IWhen deploying the air bag module and seat belt pre-
tensioner, stand at least 5 m (16 ft) away from the deployment
component.
IWhen deploying air bag module and seat belt pre-tensioner, a
fairly lou

Page 2114 of 2395

INFINITI QX4 2001  Factory Service Manual SRS020-B
5. Connect red clip of deployment tool to battery positive termi-
nal and black clip to negative terminal.
6. The lamp on the right side of the tool, marked ªdeployment tool
powerº, should