Page 765 of 4284

Symptom:
LIFTGATE CYLINDER SWITCH INPUT OPEN
When Monitored and Set Condition:
LIFTGATE CYLINDER SWITCH INPUT OPEN
When Monitored: At all times when battery power is supplied to the Body Control
Module.
Set Condition: When the BCM senses voltage to the cylinder lock switch above 4.6 volts
for over 10 seconds.
POSSIBLE CAUSES
DTC PRESENT
BODY CONTROL MODULE - LIFTGATE CYLINDER SWITCH VOLTAGE LOW
LIFTGATE CYLINDER SWITCH GROUND OPEN
LIFTGATE CYLINDER SWITCH MUX OPEN
LIFTGATE CYLINDER SWITCH OPEN
TEST ACTION APPLICABILITY
1 NOTE: When this code is present, the VTSS indicator will stay on solid during the
arming process.
With the DRBIIIt, record and erase DTC's.
With the DRBIIIt, read DTC's.
Operate the Liftgate Cylinder Switch several times while monitoring the DRBIIIt.
Does the DRBIIItdisplay LGATE CYL SW INPUT OPEN?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors.
Perform BODY VERIFICATION TEST - VER 1.
2 With the DRBIIItin Sensors, read the LGATE CYL SW voltage.
Does the DRBIIItdisplay 4.6 volts or greater?All
Ye s®Go To 3
No®Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.
3 Disconnect the Liftgate Cylinder Switch connector.
Using a 12-volt test light connected to 12-volts, check the Ground circuit.
Does the test light illuminate brightly?All
Ye s®Go To 4
No®Repair the Ground circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
736
POWER DOOR LOCKS/RKE
Page 769 of 4284

Symptom:
LIFTGATE CYLINDER SWITCH INPUT STUCK
When Monitored and Set Condition:
LIFTGATE CYLINDER SWITCH INPUT STUCK
When Monitored: At all times when battery power is supplied to the Body Control
Module.
Set Condition: When the BCM senses voltage to the cylinder lock switch between 1.3 and
3.25 for over 10 seconds.
POSSIBLE CAUSES
DTC PRESENT
BODY CONTROL MODULE - LIFTGATE CYLINDER SWITCH VOLTAGE INCORRECT
LIFTGATE CYLINDER SWITCH GROUND OPEN
LIFTGATE CYLINDER LOCK SWITCH MUX OPEN
CYLINDER LOCK SWITCH STUCK
TEST ACTION APPLICABILITY
1 NOTE: When this code is present, the VTSS indicator will stay on solid during the
arming process.
With the DRBIIIt, record and erase DTC's.
With the DRBIIIt, read DTC's.
Operate the Liftgate Cylinder Switch several times while monitoring the DRBIIIt.
Does the DRBIIItdisplay LGATE CYL SW INPUT STUCK?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors.
Perform BODY VERIFICATION TEST - VER 1.
2 With the DRBIIItin Sensors, read the LGATE CYL LOCK SW voltage.
Does the DRBIIItdisplay voltage between 1.3 and 3.25 volts?All
Ye s®Go To 3
No®Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.
3 Disconnect the Liftgate Cylinder Switch connector.
Using a 12-volt test light connected to 12-volts, check the Ground circuit.
Does the test light illuminate brightly?All
Ye s®Go To 4
No®Repair the Ground circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
740
POWER DOOR LOCKS/RKE
Page 776 of 4284

Symptom:
PASSENGER DOOR LOCK SWITCH INPUT OPEN
When Monitored and Set Condition:
PASSENGER DOOR LOCK SWITCH INPUT OPEN
When Monitored: At all times when battery power is supplied to the Body Control
Module.
Set Condition: When the BCM senses voltage to the door lock switch above 4.6 volts for
over 10 seconds.
POSSIBLE CAUSES
DTC PRESENT
BODY CONTROL MODULE - PASSENGER DOOR LOCK SWITCH VOLTAGE LOW
DOOR LOCK SWITCH GROUND OPEN
DOOR LOCK SWITCH MUX OPEN
DOOR LOCK SWITCH OPEN
TEST ACTION APPLICABILITY
1 With the DRBIIIt, record and erase DTC's.
Cycle the ignition from ON to OFF.
With the DRBIIIt, read DTC's.
Operate the door locks several times from the Passenger Door Lock Switch while
monitoring the DRBIIIt.
Does the DRBIIItdisplay PASS DOOR LOCK SW INPUT OPEN?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors.
Perform BODY VERIFICATION TEST - VER 1.
2 With the DRBIIItin Sensors, read the PASS DOOR LOCK SW voltage.
Does the DRBIIItdisplay 4.6 volts or greater?All
Ye s®Go To 3
No®Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.
3 Disconnect the Passenger Door Lock Switch connector.
Using a 12-volt test light connected to 12-volts, check the Ground circuit.
Does the test light illuminate brightly?All
Ye s®Go To 4
No®Repair the Ground circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
747
POWER DOOR LOCKS/RKE
Page 780 of 4284

Symptom:
PASSENGER DOOR LOCK SWITCH INPUT STUCK
When Monitored and Set Condition:
PASSENGER DOOR LOCK SWITCH INPUT STUCK
When Monitored: At all times when battery power is supplied to the Body Control
Module.
Set Condition: When the BCM senses voltage to the door lock switch between 1.3 and
3.25 for over 10 seconds.
POSSIBLE CAUSES
DTC PRESENT
BODY CONTROL MODULE - PASSENGER DOOR LOCK SWITCH VOLTAGE INCORRECT
DOOR LOCK SWITCH GROUND OPEN
DOOR LOCK SWITCH MUX OPEN
DOOR LOCK SWITCH STUCK
TEST ACTION APPLICABILITY
1 With the DRBIIIt, record and erase DTC's.
Cycle the ignition ON to OFF.
With the DRBIIIt, read DTCs.
Operate the door lock several times from the Passenger Door Lock Switch while
monitoring the DRBIII.
Does the DRBIIItdisplay PASS DOOR LOCK SW INPUT STUCK?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors.
Perform BODY VERIFICATION TEST - VER 1.
2 With the DRBIIItin Sensors, read the PASS DOOR LOCK SW voltage.
Does the DRBIIItdisplay voltage between 1.3 and 3.25 volts?All
Ye s®Go To 3
No®Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.
3 Disconnect the Passenger Door Lock Switch connector.
Using a 12-volt test light connected to 12-volts, check the Ground circuit.
Does the test light illuminate brightly?All
Ye s®Go To 4
No®Repair the Ground circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
751
POWER DOOR LOCKS/RKE
Page 782 of 4284

Symptom:
RIGHT CYLINDER LOCK SWITCH INPUT OPEN
When Monitored and Set Condition:
RIGHT CYLINDER LOCK SWITCH INPUT OPEN
When Monitored: At all times when battery power is supplied to the Body Control
Module.
Set Condition: When the BCM senses voltage to the cylinder lock switch above 4.6 volts
for over 10 seconds.
POSSIBLE CAUSES
DTC PRESENT
BODY CONTROL MODULE - RIGHT CYLINDER LOCK SWITCH VOLTAGE LOW
CYLINDER LOCK SWITCH GROUND OPEN
CYLINDER LOCK SWITCH MUX OPEN
CYLINDER LOCK SWITCH OPEN
TEST ACTION APPLICABILITY
1 NOTE: When this code is present, the VTSS indicator will stay on solid during the
arming process.
With the DRBIIIt, record and erase DTC's.
With the DRBIIIt, read DTCs.
Operate the door locks several times from the Right Cylinder Lock Switch while
monitoring the DRBIIIt.
Does the DRBIIItdisplay RIGHT CYL LOCK SW INPUT OPEN?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors.
Perform BODY VERIFICATION TEST - VER 1.
2 With the DRBIIItin Sensors, read the RIGHT CYL LOCK SW voltage.
Does the DRBIIItdisplay 4.6 volts or greater?All
Ye s®Go To 3
No®Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.
3 Disconnect the Right Cylinder Lock Switch connector.
Using a 12-volt test light connected to 12-volts, check the Ground circuit.
Does the test light illuminate brightly?All
Ye s®Go To 4
No®Repair the Ground circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
753
POWER DOOR LOCKS/RKE
Page 786 of 4284

Symptom:
RIGHT CYLINDER LOCK SWITCH INPUT STUCK
When Monitored and Set Condition:
RIGHT CYLINDER LOCK SWITCH INPUT STUCK
When Monitored: At all times when battery power is supplied to the Body Control
Module.
Set Condition: When the BCM senses voltage to the cylinder lock switch between 1.3 and
3.25 for over 10 seconds.
POSSIBLE CAUSES
DTC PRESENT
BODY CONTROL MODULE - RIGHT CYLINDER LOCK SWITCH VOLTAGE INCORRECT
RIGHT CYLINDER LOCK SWITCH GROUND OPEN
RIGHT CYLINDER LOCK SWITCH MUX OPEN
CYLINDER LOCK SWITCH STUCK
TEST ACTION APPLICABILITY
1 NOTE: When this code is present, the VTSS indicator will stay on solid during the
arming process.
With the DRBIIIt, record and erase DTC's.
With the DRBIIIt, read DTCs.
Operate the door lock several times from the Right Cylinder Lock Switch while
monitoring the DRBIIIt.
Does the DRBIIItdisplay RIGHT CYL LOCK SW INPUT STUCK?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors.
Perform BODY VERIFICATION TEST - VER 1.
2 With the DRBIIItin Sensors, read the RIGHT CYL LOCK SW voltage.
Does the DRBIIItdisplay voltage between 1.3 and 3.25 volts?All
Ye s®Go To 3
No®Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.
3 Disconnect the Right Cylinder Lock Switch connector.
Using a 12-volt test light connected to 12-volts, check the Ground circuit.
Does the test light illuminate brightly?All
Ye s®Go To 4
No®Repair the Ground circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
757
POWER DOOR LOCKS/RKE
Page 794 of 4284

TEST ACTION APPLICABILITY
3 Remove the power liftgate motor trim panel.
Disconnect the Power Liftgate Module C2 connector.
Disconnect the License Lamp (light bar) connector.
Measure the resistance of the liftgate Temperature Sensor Signal circuit between the
License Lamp connector and the PLG C2 connector.
Is the resistance below 5.0 ohms?All
Ye s®Go To 4
No®Repair the Liftgate Temperature Sensor Signal circuit for an
open.
Perform BODY VERIFICATION TEST - VER 1.
4 Remove the power liftgate motor trim panel.
Disconnect the Power Liftgate Module C2 connector.
Disconnect the License Lamp (light bar) connector.
Measure the resistance of the Ground circuit between the PLG C2 connector (cavity
20) and the License Lamp connector (cavity 8).
Is the resistance below 5.0 ohmsAll
Ye s®Go To 5
No®Repair the Liftgate Temperature Sensor Ground wire for an open.
Perform BODY VERIFICATION TEST - VER 1.
5 If there are no possible causes remaining, view repair. All
Repair
Replace the Liftgate Temperature Sensor (light bar).
Perform BODY VERIFICATION TEST - VER 1.
765
POWER DOORS - LIFTGATE
AMBIENT TEMPERATURE SENSOR CIRCUIT OPEN ÐContinued
Page 796 of 4284

TEST ACTION APPLICABILITY
3 Remove the power liftgate motor trim panel.
Disconnect the Power Liftgate Module C2 connector.
Measure the resistance of the liftgate Temperature Sensor Signal circuit to the
Ground circuit (cavity 20) in the PLG C2 connector.
Is the resistance below 1000.0 ohms?All
Ye s®Go To 4
No®Replace the Power Liftgate Module.
Perform BODY VERIFICATION TEST - VER 1.
4 Remove the power liftgate motor trim panel.
Disconnect the Power Liftgate Module C2 connector.
Disconnect the License Lamp (light bar) connector.
Measure the resistance of the liftgate Temperature Sensor Signal circuit to the
Ground circuit (cavity 20) in the PLG C2 connector.
Is the resistance below 1000.0 ohmsAll
Ye s®Repair the Liftgate Temperature Sensor Signal wire for a short to
the Ground wire.
Perform BODY VERIFICATION TEST - VER 1.
No®Replace the Liftgate Temperature Sensor (light bar).
Perform BODY VERIFICATION TEST - VER 1.
767
POWER DOORS - LIFTGATE
AMBIENT TEMPERATURE SENSOR CIRCUIT SHORT TO GROUND Ð
Continued