2000 SUZUKI SWIFT 6b-

[x] Cancel search: 6b-

Page 385 of 557

SUZUKI SWIFT 2000 1.G SF310 Service Workshop Manual 2. Thermostat case
2. Thermometer
3. Heater
Upside
6B-8 ENGINE COOLING
4) Remove thermostat (1).
INSPECTION
1) Make sure that air bleed valve (1) of thermostat is clean.
Should this valve be clogged,

Page 386 of 557

SUZUKI SWIFT 2000 1.G SF310 Service Workshop Manual ENGINE COOLING 6B-9
WATER PUMP
1) Disconnect negative cable at battery.
2) Drain cooling system.
3) Remove timing belt and tensioner according to procedure de-
scribed in “TIMING BELT AND TENSIONER

Page 387 of 557

SUZUKI SWIFT 2000 1.G SF310 Service Workshop Manual 6B-10 ENGINE COOLING
5) Install crankshaft pulley, water pump pulley, and pump drive
belt referring to Section 6A or 6A1.
6) Adjust water pump belt tension.
7) Install fender apron extension on right
Page:   < prev 1-8 9-16