2000 SUZUKI SWIFT evaporator

[x] Cancel search: evaporator

Page 67 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual 1B-2 AIR CONDITIONING (OPTIONAL)
REMOVING MANIFOLD GAUGE SET ......  1B-26
LEAK TEST................................................  1B-26
LIQUID LEAK DETECTORS ..................  1B-26
ON-VEHICLE S

Page 68 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual AIR CONDITIONING (OPTIONAL) 1B-3
GENERAL DESCRIPTION
REFRIGERANT CIRCULATION
REFRIGERANT TYPE
Whether the A/C in the vehicle being serviced uses HFC-134a
(R-134a) or CFC-12 (R-12) is indicated on comp

Page 70 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual AIR CONDITIONING (OPTIONAL) 1B-5
DIAGNOSIS
GENERAL DIAGNOSIS TABLE
Condition Possible Cause Correction
Cool air won’t come 
out (A/C system won’t 
operative)No refrigerant Perform recover, evacuat

Page 71 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual 1B-6 AIR CONDITIONING (OPTIONAL)
Cool air won’t come 
out or insufficient 
cooling (A/C system 
normal operative)Insufficient or excessive charge of 
refrigerantCheck charge of refrigerant and syste

Page 73 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual 1B-8 AIR CONDITIONING (OPTIONAL)
ABNORMAL NOISE FROM CRANKSHAFT PULLEY
ABNORMAL NOISE FROM TENSION PULLEY
ABNORMAL NOISE FROM A/C EVAPORATOR
ABNORMAL NOISE FROM BLOWER FAN MOTOR
Condition Possible Cau

Page 75 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual 1B-10 AIR CONDITIONING (OPTIONAL)
PERFORMANCE DIAGNOSIS
1) Confirm that vehicle and environmental conditions are as fol-
lows.
Vehicle is not exposed to direct sun.
Ambient temperature is within 15

Page 76 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual AIR CONDITIONING (OPTIONAL) 1B-11
8) Check for each pressure of low side and high side if it is
within shaded range of graph. 
If each gauge reading is out of specified pressure, correct
defective par

Page 77 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual 1B-12 AIR CONDITIONING (OPTIONAL)
PERFORMANCE DIAGNOSIS TABLE
HIGH PRESSURE GAUGE
LOW PRESSURE GAUGE
THERMOMETER AT CENTER DUCT
NOTE:
If ambient temperature is approximately 30°C (86°F), it is possi
Page:   1-8 9-16 17-24 25-32 32 next >