SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual 6-40 ENGINE GENERAL INFORMATION AND DIAGNOSIS
For TYPE B (For applicable mode, refer to NOTE in “ECM VOLTAGE VALUES TABLE”) G02 17 Power source for back-up 10 – 14 V Anytime
TERMINAL NO. CIRCUIT

Page 451 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual 6-82 ENGINE GENERAL INFORMATION AND DIAGNOSIS
DTC CONFIRMATION PROCEDURE
1) Turn ignition switch OFF.
2) Clear DTC with ignition switch ON.
3) Check vehicle and environmental condition for :
–Altitu

Page 502 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual ENGINE MECHANICAL (M13 ENGINE) 6A1-1
6F1
6A1
6G
6H
6K
7A
7A1
7B1
7C1
7D
7E
7F
8A
8B
8C
8D
8E
9
10B
SECTION 6A1
ENGINE MECHANICAL (M13 ENGINE)
CONTENTS
GENERAL DESCRIPTION .............................

Page 504 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual ENGINE MECHANICAL (M13 ENGINE) 6A1-3
ENGINE LUBRICATION
The oil pump is of a trochoid type, and mounted on the crankshaft. Oil is drawn up through the oil pump strainer
and passed through the pump to

Page 505 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual 6A1-4 ENGINE MECHANICAL (M13 ENGINE)
DIAGNOSIS
DIAGNOSIS TABLE
Refer to “ENGINE MECHANICAL DIAGNOSIS TABLE” in Sec-
tion 6.
COMPRESSION CHECK
Check compression pressure on all 4 cylinders as follo

Page 508 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual ENGINE MECHANICAL (M13 ENGINE) 6A1-7
4) Connect special tool (Vacuum gauge) to intake manifold.
Special tool
(A) : 09915-67310
5) Run engine at specified idle speed and read vacuum gauge.
Vacuum shoul

Page 509 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual 6A1-8 ENGINE MECHANICAL (M13 ENGINE)
2) Install special tools (Oil pressure gauge) to vacated threaded
hole.
Special tool
(A) : 09915-77310
(B) : 09915-78211
3) Start engine and warm it up to normal o

Page 526 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual ENGINE MECHANICAL (M13 ENGINE) 6A1-25
TIMING CHAIN COVER
REMOVAL
1) Disconnect negative cable at battery.
2) Disconnect the following electric lead wires, and remove
these connector bracket.
CMP sens