HONDA CIVIC 2000 6.G Workshop Manual Mode control motor does not run.
or one or more modes arc inope]a-
tive.
Check the No. 17 (7.5 A) fuse in
the under-dash fuse/relay box.
Replace the Iuse. and recheck.
Check for an open in the wire:
1

Page 1401 of 2189

HONDA CIVIC 2000 6.G Workshop Manual Recirculation control door does
not chango betwe€n Fresh and
Recirculate.
Check the No. l7 (7.5 A) fuse an the
underdash fuse/relay box.
Replace the fuse, and recheck.
Check lor an oPen in the wite:

Page 1405 of 2189

HONDA CIVIC 2000 6.G Workshop Manual Blower Motor
BLOWER MOTOR 2P CONNECTOR
Wire side of lemale terminals
JUMPERWIRE
(contd)
21-31
Blower motor does not run at all.
Check the No. 55 (40 A) Iuse in
the under-hood fuse/relay box,
and the

Page 1409 of 2189

HONDA CIVIC 2000 6.G Workshop Manual Both heater and A/C do nol work.
checkthe No.47 (7.5 A)fuse in the
under-hood fuse/relay box, and theNo. 17 {7.5 A) fuse in the under-
dash fuse/relay box.
ReDlace the tuse{s), and recheck.
Check lor

Page 1410 of 2189

HONDA CIVIC 2000 6.G Workshop Manual Troubleshooting -99 - 00 Models
Heater Control Panel Input/Output Signals
HEATER CONTROL PANEL CONNECTORS
8P CONNECTOR2OP CONNECTOR12P CONNECTOR
Wire side of female terminals
8P CONNECTOR (O qn Circu

Page 1411 of 2189

HONDA CIVIC 2000 6.G Workshop Manual Blower Unit
Replacement
NOTE: The blower motor, recirculation control motor
and blower resistor can bs replacsd without rsmoving
th€ blower unit (see neld Page).
1. Move the temperature control to "

Page 1414 of 2189

HONDA CIVIC 2000 6.G Workshop Manual Heater Unit
Replacement (contdl
6.
7.
8.
9.
Remove the dashboard (see section 20).
Remove the heater duct (see page 21-37) or evapo-
rator (see page 22-28).
Disconnect the connectors from the mode co

Page 1416 of 2189

HONDA CIVIC 2000 6.G Workshop Manual Heater Control Panel
95 - 98 modolsi
Remove the drivers dashboard lower cover, the
glove box and the center dashboard lower cover(see section 20).
Disconnect the air mix control cabls from the heate