HONDA CIVIC 2000 6.G Workshop Manual Troubleshooting
Condenser Fan (contd)
CONDENSER FAN RELAY 4P SOCKET
CONDENSEB FAN 2P CONNECTORWire side of female terminals
-=F_
l!.lI slx
@I
Check tor an opon in the wi.o:1. Disconnect the jumper wi

Page 1439 of 2189

HONDA CIVIC 2000 6.G Workshop Manual Frcm page 22-14
Check lor an open in the wire:1. Turn the ignition switch OFF.
2. Disconnect the A/C pressure
switch 2P connector.3. Turn th ignition switch ON lll).4. Measure the voltage between
the

Page 1441 of 2189

HONDA CIVIC 2000 6.G Workshop Manual A/C System
CONDENSER FAN RELAY 4P SOCKET
A/C system does not come on
{comDressor and fan).
Check the No. 56 fuse in theunderhood fuse/relay box andthe No. 17 fuse in the under-dashfuse/relay box.
ReD

Page 1442 of 2189

HONDA CIVIC 2000 6.G Workshop Manual Troubleshooting
A/C System (contd)
From page 22-11
. _Ff,, __
I11213[
,r,il*"-T",-.r-..owrRE I
To page 22-19 196 - 98 models)
A/C THERMOSTAT 3P CONNECTOR
Wire side oI female terminals
Check tor an

Page 1443 of 2189

HONDA CIVIC 2000 6.G Workshop Manual Ftom page 22 18
Check tor an open in the wire:1. Turn the ignition switch OFF,then disconnect the iu mper
2. Remove the center dashboardlower cover lsee section 20),
and disconnect the heater con
tro

Page 1445 of 2189

HONDA CIVIC 2000 6.G Workshop Manual A/C ThermostatRelays
Test
1.Remove the AyC thermostat (see page 22-29).
Connect baftery power to the No. 3 terminal, ground
the No. 2 terminal, and connect a test light between
the No. 1 and No. 3 te

Page 1448 of 2189

HONDA CIVIC 2000 6.G Workshop Manual A/C System Service
Performance Test
The performance test will help determine if the air con-
ditioner system is operating within specifications.
Use only service equipment that is U.L.-listed and is c

Page 1450 of 2189

HONDA CIVIC 2000 6.G Workshop Manual A/C System Service
Pressure Test Chart
NOTE: Performance Test is on page 22-24,
Test resultsRelated symptomsProbabl€ causeRemedy
Discharge (high)
pressure aDnor-
mally high
After stopping compressor