Downloaded from www.Manualslib.com manuals search engine AIR
CONDITIONING
250
ESSENTIAL: The compressor lubricant is extremely hygroscopic; always use FRESH oil.
SPECIAL FEATURES : AIR CONDITIONING SYSTEM (R 134.a)
Compressor lubricant.
Checking the compressor oil level.
There are three specific cases :
- 1/Repairs to a system without leaks.
- 2/Slow leak.
- 3/Fast leak.
1/ Repairing a system without leaks..
a) - Using draining/recovery equipment not fitted with an oil decanter.
- Drain the system as slowly as possible via the LOW PRESSURE valve, so as not to lose any oil.
- No more oil should be added when filling the system with R 134.a fluid.
b) - Using draining/filling equipment fitted with an oil decanter.
- Drain the R 134.a fluid from the system in accordance with the instructions in the equipment handbook.
- Measure the amount of oil recovered.
- Add the same amount of NEW oil when filling the system with R 134.a fluid.
c) - Replacing a compressor.
- Remove the old compressor, drain it and measure the oil quantity.
- Drain the new compressor (supplied full), so that the same amount of NEW oil is left in the compressor as was in the old compressor.
- No more oil should be added when filling the system with R 134.a fluid.
Downloaded from www.Manualslib.com manuals search engine SPECIAL FEATURES : AIR CONDITIONING SYSTEM (R 134.a)
Checking the compressor oil level (continued)
2/ Slow leak.
- Slow leaks do not lead to oil loss, therefore the same procedure should be followed as if there was no leak at all.
3/ Fast leak.
This type of leak causes both oil loss as well as allowing air to enter the system.
It is therefore necessary to :
- Replace the dryer.
- Drain as much oil as possible (when replacing the faulty component).
Either before or during filling of the system with R 134.a fluid, introduce 80 ccof NEW oil into the system.