1999 SUZUKI GRAND VITARA Section 8f

[x] Cancel search: Section 8f

Page 424 of 801

SUZUKI GRAND VITARA 1999 2.G Service Workshop Manual YH4
GRAND
VITARA
7B1-22 AUTOMATIC TRANSMISSION (4 A / T)
1. CUSTOMER COMPLAINT ANALYSIS
Record details of the problem (failure, complaint) and how it occurred as described by the customer.
For this pu

Page 426 of 801

SUZUKI GRAND VITARA 1999 2.G Service Workshop Manual YH4
GRAND
VITARA
7B1-24 AUTOMATIC TRANSMISSION (4 A / T)
MALFUNCTION INDICATOR LAMP (MIL) CHECK
Refer to the same item in Section 6 / 6-1 for checking procedure.
ªO / D OFFº LAMP CHECK
1) Check that

Page 428 of 801

SUZUKI GRAND VITARA 1999 2.G Service Workshop Manual YH4
GRAND
VITARA
7B1-26 AUTOMATIC TRANSMISSION (4 A / T)
Operation
VISUAL INSPECTION
Visually check following parts and systems.
INSPECTION ITEM
REFERRING SECTION
A / T fluid ± ± ± ± ± level, le

Page 429 of 801

SUZUKI GRAND VITARA 1999 2.G Service Workshop Manual YH4
GRAND
VITARA
AUTOMATIC TRANSMISSION (4 A / T) 7B1-27
A / T BASIC CHECK
This inspection is important for troubleshooting when PCM (ECM) has detected no DTC and no abnormality has
been noted in visu

Page 432 of 801

SUZUKI GRAND VITARA 1999 2.G Service Workshop Manual YH4
GRAND
VITARA
7B1-30 AUTOMATIC TRANSMISSION (4 A / T)
Running condition Gear shift Abnormal
noise
ConditionPossible CauseCorrection
Poor 1st speed run-
ning or excessive
slippage in ªDº or ª2º

Page 433 of 801

SUZUKI GRAND VITARA 1999 2.G Service Workshop Manual YH4
GRAND
VITARA
AUTOMATIC TRANSMISSION (4 A / T) 7B1-31
Brake pedal Released Depressed
Voltage 0 VBattery
voltage
DIAGNOSTIC FLOW TABLE A-1 (NO TCC LOCK-UP OCCURS)
SYSTEM DESCRIPTION
PCM turns TCC so

Page 435 of 801

SUZUKI GRAND VITARA 1999 2.G Service Workshop Manual YH4
GRAND
VITARA
AUTOMATIC TRANSMISSION (4 A / T) 7B1-33
O / D cut
switchOFF ON
VoltageBattery
voltage0 V
DIAGNOSTIC FLOW TABLE A-2 (NO GEAR SHIFT TO O / D)
SYSTEM DESCRIPTION
PCM does not shift to O

Page 438 of 801

SUZUKI GRAND VITARA 1999 2.G Service Workshop Manual YH4
GRAND
VITARA
7B1-36 AUTOMATIC TRANSMISSION (4 A / T)
Switch ON
positionSwitch OFF
positionSwitch ON
position
Switch OFF
position
DIAGNOSTIC FLOW TABLE B-2 ªO / D OFFº LIGHT CIRCUIT CHECK
(ªO /