YH4
GRAND
VITARA
Example: When right-front wheel speed sensor circuit opens (DTC 21)
1. Diagnosis connector
(6 pins connector)
2. Ground terminal3. Diag. switch terminal
4. Service wire
Voltmeter indicator
(or ªABSº warning
lamp)HIGH
(ON)
LOW
(OFF)
Time (sec.)
1. EBD warning lamp
(brake warning lamp)
ANTILOCK BRAKE SYSTEM (ABS) (OPTIONAL) 5E1-11
EBD WARNING LAMP (BRAKE WARNING
LAMP) CHECK
NOTE:
Perform this check on a level place.
1) Turn ignition switch ON with parking brake applied.
2) Check that brake warning lamp is turned ON.
3) Release parking brake with ignition switch ON and check that
EBD warning lamp (brake warning lamp) goes off.
If it doesn't go off, go to ªTABLE-Eº in this section.
ªABSº WARNING LAMP CHECK
1) Turn ON the ignition switch.
2) Check that ªABSº warning lamp lights for about 2 seconds and
then goes OFF.
If anything faulty is found, advance to Diagnostic table ± A, B or
C.
DIAGNOSTIC TROUBLE CODE (DTC) CHECK
(USING ªABSº WARNING LAMP)
1) Using service wire, connect diag. switch terminal of diagnosis
connector to ground.
2) Turn ignition switch ON.
3) Read flashing of ªABSº warning lamp which represents DTC as
shown in example below and write it down. When more than 2
DTC's are stored in memory, deflection and flashing for each
DTC is repeated three times starting with the smallest DTC num-
ber in increasing order.
For details of DTC, refer to ªDTC Tableº.
YH4
GRAND
VITARA
ANTILOCK BRAKE SYSTEM (ABS) (OPTIONAL) 5E1-17
1. ABS hydraulic
unit / control
module connector
TABLE ± B ªABSº WARNING LAMP CIRCUIT CHECK ± LAMP COMES ªONº
STEADY
Refer to TABLE ± A for System Circuit Diagram and Circuit Description.
INSPECTION
STEPACTIONYESNO
1Perform diagnostic trouble code check. Is there any DTC
(including code No.12, NO CODES on SUZUKI scan
tool) exists?Go to step 2.Go to step 3.
2Is malfunction DTC (other than code No.12) exists at step
1?Go to step 7 of ABS
diagnostic flow table
in this section.Go to step 3.
31) Disconnect ABS hydraulic unit / control module
connector. (See Fig. 1)
2) Check for proper connection to ABS hydraulic
unit / control module connector at terminals ªA17º,
ªA25º and ªA10º.
3) If OK, turn ignition switch ªONº and measure
voltage at terminal ªA25º of connector.
Is it 10 ± 14 V?Go to step 4.ªB / Wº circuit open.
41) With ABS control module connector disconnected,
turn ignition switch ON and light ABS warning lamp.
2) Connect terminal ªA17º of disconnected connector to
ground using service wire.
Does ªABS warning lampº turn off?Go to step 5.ªBl / Oº circuit open.
If wire and
connection are OK,
replace ABS lamp
driver module.
51) Measure resistance from connector terminal ªA10º
to body ground.
Is continuity indicated?Substitute a
known-good ABS
hydraulic unit /
control module
assembly and
recheck.ªBº circuit open.
Fig. 1
YH4
GRAND
VITARA
5E1-18 ANTILOCK BRAKE SYSTEM (ABS) (OPTIONAL)
-1. ªABSº warning lamp
-2. ABS hydraulic unit /
control module assembly
-3. Diagnosis connector
3-1. Diag. switch terminal
3-2. Diag. ground terminal
TABLE ± C ªABSº WARNING LAMP CIRCUIT CHECK ± THE LAMP FLASHES
CONTINUOUSLY WHILE IGNITION SWITCH IS ON
CIRCUIT DESCRIPTION
When the diag. switch terminal is shorted or connected to the ground with the ignition switch ON, the diag. trouble
code (DTC) is indicated by flashing of the ªABSº warning lamp only in following cases.
Normal DTC (12) is indicated if no malfunction DTC is detected in the ABS.
A history malfunction DTC is indicated by flashing of the lamp if a current malfunction DTC is not detected at that
point although a history malfunction DTC is stored in memory.
INSPECTION
STEPACTIONYESNO
1Is diag. switch terminal connected to ground via
service wire?Go to step 3.Go to step 2.
21) Ignition switch ON.
2) Measure voltage between diag. switch terminal
and ground.
Is it 10 ± 14 V?Substitute a
known-good ABS
hydraulic unit /
control module
assembly and
recheck.ªPº wire circuit
shorted to
ground.
31) Ignition switch ON.
2) Does flashing of ªABSº warning lamp indicate
DTC (DTC 12 or history DTC)?Go to step 7 of ABS
diagnostic flow
table in this
section.Substitute a
known-good ABS
hydraulic unit /
control module
assembly and
recheck.
YH4
GRAND
VITARA
5E1-26 ANTILOCK BRAKE SYSTEM (ABS) (OPTIONAL)
1. ABS hydraulic unit/
control module assembly
2. ABS hydraulic unit/
control module
connector of harness
1. ABS hydraulic
unit / control
module connector
DTC 41 (DTC C1041 / C1042) ± RIGHT-FRONT SOLENOID CIRCUIT
DTC 45 (DTC C1045 / C1046) ± LEFT-FRONT SOLENOID CIRCUIT
DTC 56 (DTC C1055 / C1056) ± REAR SOLENOID CIRCUIT
DESCRIPTION
The ABS control module monitors the voltage of the terminal of the solenoid circuit constantly with the ignition
switch turned ON. It sets this DTC when the terminal voltage does not become low / high for the ON / OFF command
to the solenoid or the voltage difference between solenoid circuit terminals exceeds the specified value with the
solenoid turned OFF.
INSPECTION
STEPACTIONYESNO
11) Check solenoid referring to item
ªABS HYDRAULIC UNIT OPERATION CHECKº
in this section.
Is it in good condition?Check terminals ªA11º
and ªA27º connection.
If connections OK,
substitute a known-
good ABS hydraulic
unit / control module
assembly and
recheck.Go to step 2.
21) Ignition switch OFF.
2) Disconnect ABS hydraulic unit / control module
connector. (See Fig. 1)
3) Check for proper connection to ABS hydraulic
unit / control module connector at terminal ªA11º.
4) If OK, then measure voltage between terminal
ªA11º of module connector and body ground.
Is it 10 ± 14 V?Substitute a known-
good ABS hydraulic
unit / control module
assembly and
recheck.ªW / Blº circuit open.
Fig. 1
YH4
GRAND
VITARA
ANTILOCK BRAKE SYSTEM (ABS) (OPTIONAL) 5E1-27
1. ABS hydraulic unit/
control module assembly
2. ABS hydraulic unit/
control module
connector
1. ABS hydraulic
unit / control
module connector
DTC 57 (DTC C1057) ± SOLENOID AND PUMP MOTOR POWER SOURCE
CIRCUIT
DESCRIPTION
The ABS control module monitors the voltage at terminal ( ªA11º and ªA27º) of the fail-safe and pump motor relays
circuit constantly with the ignition switch turned ON. When all solenoid circuit voltages are below the specified value
or the voltage at the terminal ªA27º became below the specified value while the pump motor is operating, this DTC
will be set. As soon as the voltage rises to the specified level, the set DTC will be cleared.
INSPECTION
STEPACTIONYESNO
1Check battery voltage. Is it about 11 V or higher?Go to step 2.Check charging
system referring
to ªCHARGING
SYSTEMº section.
2Check ABS main fuse and connection. Is it in good
condition?Go to step 3.Repair and / or
replace fuse.
31) Ignition switch OFF.
2) Disconnect ABS hydraulic unit / control module
connector. (See Fig. 1)
3) Check proper connection to ABS hydraulic unit /
control module connector at terminal ªA27º.
4) If OK, then measure voltage between connector
terminal ªA27º and body ground.
Is it 10 ± 14 V?Substitute a
known-good
ABS hydraulic
unit / control
module assembly
and recheck.ªW / Blº circuit open.
Fig. 1
YH4
GRAND
VITARA
5E1-28 ANTILOCK BRAKE SYSTEM (ABS) (OPTIONAL)
-1. ABS hydraulic unit /
control module assembly
1-1. ABS pump motor relay
1-2. ABS pump motor
1-3. ABS fail safe relay
-2. ABS hydraulic unit/
control module connector
of harness
1. ABS hydraulic
unit / control
module connector
DTC 61 (DTC C1061) ± ABS PUMP MOTOR CIRCUIT
DESCRIPTION
The ABS control module monitors the voltage at the monitor terminal of the pump motor circuit constantly with the
ignition switch turned ON. It sets this DTC when the voltage at the monitor terminal does not become high / low
according to ON / OFF commands to the motor relay of the module (does not follow these commands).
INSPECTION
STEPACTIONYESNO
11) Check pump motor referring to item
ªABS HYDRAULIC UNIT OPERATION
CHECKº in this section.
Is it in good condition?Check terminals ªA11º
and ªA27º connection.
If connections OK,
substitute a known-
good ABS hydraulic
unit / control module
assembly and recheck.Go to step 2.
21) Ignition switch OFF.
2) Disconnect ABS hydraulic unit / control
module connector. (See Fig. 1)
3) Check for proper connection to ABS
hydraulic unit / control module connector
at terminal ªA27º.
4) If OK, then measure voltage between
terminal ªA27º of module connector
and body ground.
Is it 10 ± 14 V?Go to step 3.ªW / Blº circuit open.
3Measure resistance between connector
terminal ªA28º of ABS hydraulic unit / control
module assembly.
Is it infinite ()?ªBº circuit open.Substitute a known-
good ABS hydraulic
unit / control module
assembly and recheck.
Fig. 1
YH4
GRAND
VITARA
ANTILOCK BRAKE SYSTEM (ABS) (OPTIONAL) 5E1-29
1. Ignition switch
2. ABS hydraulic unit/
control module assembly
3. ABS hydraulic unit/
control module connector
of harness 2
1. ABS hydraulic
unit / control
module connector
DTC 63 (DTC C1063) ± ABS FAIL-SAFE RELAY CIRCUIT
DESCRIPTION
The ABS control module monitors the voltage at the terminal of the solenoid circuit constantly with the ignition
switch turned ON. Also, immediately after the ignition switch is turned ªONº, perform an initial check as follows.
Switch the fail-safe relay in the order of ON OFF ON and check if the voltage at 6 solenoid circuit terminals
changes to High Low High. If anything faulty is found in the initial check and when the voltage at all solenoid
circuit terminals is low with the ignition switch turned ON and ABS not operated, this DTC will be set.
INSPECTION
STEPACTIONYESNO
1Check battery voltage. Is it about 11 V or higher?Go to step 2.Check charging
system referring
to ªCHARGING
SYSTEMº section.
2Check ABS main fuse and connection. Is it in good
condition?Go to step 3.Repair and / or
replace fuse.
31) Ignition switch OFF.
2) Disconnect ABS hydraulic unit / control module
connector. (See Fig. 1)
3) Check proper connection to ABS hydraulic unit /
control module at terminal ªA11º.
4) If OK, then measure voltage between connector
terminal ªA11º, and body ground.
Is it 10 ± 14 V?Substitute a
known-good ABS
hydraulic unit /
control module
assembly and
recheck.ªW / Blº circuit open
or short to ground.
Fig. 1
YH4
GRAND
VITARA
ANTILOCK BRAKE SYSTEM (ABS) (OPTIONAL) 5E1-31
1. Diagnosis
connector
(6 pins connector)
2. Diag. switch
terminal
3. Ground
4. Service wire
Brake
pedal
Ignition
sw.
Motor
Solenoid
Rear3.0 sec.
3.0
ON-VEHICLE SERVICE
PRECAUTION
When connector are connected to ABS hydraulic unit / control mod-
ule assembly, do not disconnect connectors of sensors and turn
ignition switch ON. Then DTC will be set in ABS control module.
ABS HYDRAULIC UNIT OPERATION CHECK
1) Check that basic brake system other than ABS is in good condi-
tion.
2) Check that battery voltage is 11V or higher.
3) With ªABSº warning lamp, check that no abnormality is de-
tected in ABS. Refer to ªDIAGNOSTIC TROUBLE CODE
(DTC) CHECKº in this section.
4) Lift up vehicle.
5) Set transmission to neutral and release parking brake.
6) Turn each wheel gradually by hand to check if brake dragging
occurs. If it does, correct.
7) With diag. switch terminal of diagnosis connector connected to
ground by using service wire, turn ignition switch ON and check
if ªABSº warning lamp indicates DTC 12.
8) Turn ignition switch OFF.
9) Perform following checks with help of another person.
Brake pedal should be depressed and then ignition switch
turned ON by one person and wheel should be turned by
another person's hand. At this time, check that:
Operation sound of solenoid is heard and wheel turns only
about 0.5 sec. (Brake force is depressurized).
Operation sound of pump motor is heard and pulsation is felt
at brake pedal.
10) If all 4-wheels cannot be checked during one ignition cycle
(OFF ON), repeat Steps 8) and 9) till all 4 wheels are
checked.
If a faulty condition is found in Steps 9) and 10), replace hydrau-
lic unit / control module assembly.
11) Turn ignition switch OFF and remove service wire from diagno-
sis connector.