REAR AXLE – On-vehicle Service 27-33
TORQUE TRANSFER MECHANISM
1. Remove the drain plug to discharge the gear oil.
2. Fit the drain plug and tighten it to the specified torque.
3. Remove the filler plug.
4. Pour the specified gear oil up to the bottom end of the
filler plug hole using an oil syringe (recommended tool)
through the gap between the body and the differential
support arm.
Specified gear oil:
MITSUBISHI GENUINE DIA QUEEN SUPER AYC
FLUID
Quantity used: 0.70
0
0.05
5. Fit the filler plug and tighten it to the specified torque.
FLUID LEVEL CHECK
1. Remove the maintenance lid located in the luggage
compartment.
2.
If the vehicle has been run, leave it for 5 min. or more
in an ordinary temperature (10C to 30C) to allow the
accumulator internal pressure to drop.
NOTE
If the ambient temperature is less than 10C or less,
allow more time to leave the vehicle to stand idle.
Connect the MUT-II to the 16-pin diagnosis connector.
Turn on the ignition switch. Operate the MUT-II (Item
No.11) to activate the hydraulic unit forcibly for removing
the pressure from inside the accumulator.
Caution
Before connecting or disconnecting the MUT-II,
always turn off the ignition switch.
NOTE
(1) The forced activation (oil level check mode) will be
automatically canceled as soon as the directional
valve in the hydraulic unit is activated to the left and
right 20 times.
It can also be canceled forcibly by operating the clear
key on the MUT-II.
(2) While this function is being disabled by the fail-safe
function, the forced activation of the hydraulic unit
can not be executed.
3. Check that the fluid level in the oil reservoir is in the
range between MAX and MIN.
4. If the fluid level is lower than MIN, add the specified
fluid.
Specified fluid: Dia Queen ATF SP II or equivalent
5. Reinstall the maintenance lid.
Gear oil
Drain plug
49 Nm
Oil syringe
(Recommended tool)
Filler plug
49 Nm
REAR AXLE – On-vehicle Service REAR AXLE – On-vehicle Service 27-34
BLEEDING
1. Lift up the vehicle.
2. Connect the MUT-II to the 16-pin diagnosis connector.
Caution
Before connecting or disconnecting the MUT-II,
always turn off the ignition switch.
3. Turn on the ignition switch.
4. Operate the MUT-II (Item No.10) to activate the hydraulic
unit forcibly.
NOTE
(1) The forced activation (air bleeding mode) will be
automatically canceled after 5 minutes operation. It
can also be canceled forcibly by operating the clear
key on the MUT-II.
(2) While this function is being disabled by the fail-safe
function, the forced activation of the hydraulic unit
can not be executed.
5. Remove the cap of the left bleeder screw on the torque
transfer differential and connect a vinyl hose.
6. Gradually turn the steering wheel clockwise from the
straight-ahead position. At this time, loosen the left bleeder
screw and check that fluid is discharged with air.
7. After air has been completely discharged, tighten the
bleeder screw.
Caution
While the system is being bled of air, add fluid as
necessary to ensure that it is left in the oil reservoir
during the entire procedure.
8. Repeat steps (6) and (7) two to three times until no air
bubbles are recognized in the fluid that comes out. Then,
tighten the bleeder screw to the specified torque.
Tightening torque: 9 Nm
9. Perform steps (5) through (8) for the right bleeder screw.
Note, however, that the steering wheel should be turned
counterclockwise.
10. After the system has been completely bled of air, check
for the fluid level. (Refer to P.27-33.)
Caution
If the system is not completely bled of air, the hydraulic
unit could generate noise, degrading pump durability.
AYC OPERATION CHECK
1. Lift up the vehicle.
2. Connect the MUT-II to the 16-pin diagnosis connector.
Caution
Before connecting or disconnecting the MUT-II, always
turn off the ignition switch.
3. Start the engine.
4. Operate the MUT-II with the transmission in 2nd or a
higher gear and check to ensure that the vehicle speed
is higher than 10 km/h using the Data List (Item 10).
Bleeder
screws Vinyl hose