Page 416 of 558
– Compressor and Tension Pulley HEATER AND MANUAL
AIR CONDITIONER55-26
MAGNETIC CLUTCH
DISASSEMBLY AND REASSEMBLY
46
2 1
53
Disassembly steps
EAir gap adjustment
AD1. Self-locking nut
C2. Armature
3. ShimsB4. Snap ring
5. Rotor
A6. Field core
DISASSEMBLY SERVICE POINT
ASELF-LOCKING NUT REMOVAL
REASSEMBLY SERVICE POINTS
AFIELD CORE INSTALLATION
When installing the field core to the compressor body, install
so that the pin hole of the compressor body and the field
core projection are aligned.
MB991386
MB991367
Field core
projection
Compressor
body pin hole
Page 419 of 558
– Condenser and Condenser Fan HEATER AND MANUAL
AIR CONDITIONER55-29
REMOVAL SERVICE POINTS
AFAN MOTOR AND SHROUD ASSEMBLY
REMOVAL
Remove the clamp bolt of the power steering oil cooler pipe.
Remove the fan motor and shroud assembly while pulling
the power steering oil cooler pipe toward you.
BDISCHARGE HOSE / LIQUID PIPE A
DISCONNECTION
Plug the open end of the disconnected hose and the opening
in the cooling unit not to let foreign matter get into them.
Caution
Seal the hoses completely, otherwise the compressor
oil and receiver will absorb water vapour easily.
CCONDENSER REMOVAL
Move the radiator to the engine side and then lift up the
condenser to remove it.
INSPECTION
CONDENSER FAN MOTOR CHECK
Battery connection terminalCondenser fan operation
12
Rotate
Condenser
Page 423 of 558
FULL-AUTOMATIC AIR CONDITIONER –
General / Service Specifications /
Lubricants / Special Tools55-33
FULL-AUTOMATIC AIR CONDITIONER
GENERAL
OUTLINE OF CHANGE
The following service procedures have been established.
SERVICE SPECIFICATIONS
ItemsStandard value
Idle speed r/min750 50
Idle-up speed r/min850 50
Air gap (Compressor) mm0.4 – 0.6
Air mix damper potentiometer
resistance kΩ
MAX. HOT position4.82
resistance kΩMAX. COOL position0.18
Outlet air changeover damper
potentiometer resistance kΩ
DEF position0.18
potentiometer resistance kΩFACE position4.82
LUBRICANTS
ItemsSpecified lubricantsQuantity
Compressor oil mSUN PAG 56120 – 140
Each connection of refrigerant lineSUN PAG 56As required
Refrigerant gR134a (HFC-134a)555 – 595
SPECIAL TOOLS
ToolNumberNameUse
MB991502MUT-II
sub-assemblyInspection of full-automatic air conditioner
MB991529Diagnosis code
check harnessInspection of full-automatic air conditioner
using a voltmeter
Page 424 of 558

FULL-AUTOMATIC AIR CONDITIONER – Troubleshooting55-34
TROUBLESHOOTING
STANDARD FLOW OF DIAGNOSTIC TROUBLESHOOTING
Refer to GROUP 00 – How to Use Troubleshooting/Inspection Service Points.
DIAGNOSIS FUNCTION
DIAGNOSIS CODES CHECK
Connect the MUT-II or a voltmeter to the diagnosis connector (16-pin), then check diagnosis codes.
(Refer to GROUP 00 – How to Use Troubleshooting/Inspection Service Points.)
ERASING DIAGNOSIS CODES
Refer to GROUP 00 – How to Use Troubleshooting/Inspection Service Points.
INSPECTION CHART FOR DIAGNOSIS CODES
Code No.Diagnosis itemReference
page
11Inside air temperature sensor system (open circuit)55-34
12Inside air temperature sensor system (short circuit)55-34
13Outside air temperature sensor system (open circuit)55-35
14Outside air temperature sensor system (short circuit)55-35
15Heater water temperature sensor system (open circuit)55-36
16Heater water temperature sensor system (short circuit)55-36
21Air thermo sensor system (open circuit)55-37
22Air thermo sensor system (short circuit)55-37
31Potentiometer system of air mix damper assembly55-38
32Potentiometer system of air outlet changeover damper assembly55-39
41Drive system of air mix damper motor assembly55-40
42Drive system of air outlet changeover damper motor assembly55-40
INSPECTION PROCEDURES FOR DIAGNOSIS CODES
Code No.11 Inside air temperature sensor system (open
circuit)Probable cause
This diagnosis code is output if the power supply line or input line of the inside
air temperature sensor inside A/C-ECU is open-circuited and no signal is input
from the inside air temperature sensor to A/C-ECU.Malfunction of the A/C-ECU
Replace the A/C-ECU.
Code No.12 Inside air temperature sensor system (short
circuit)Probable cause
This diagnosis code is output if the power supply line or input line of the inside
air temperature sensor inside A/C-ECU is short-circuited and inside air
temperature sensor power supply voltage signals are input to A/C-ECU.Malfunction of the A/C-ECU
Replace the A/C-ECU.
Page 446 of 558
FULL-AUTOMATIC AIR CONDITIONER –
Troubleshooting /
On-vehicle Service55-56
Terminal
No.Normal condition Check condition Check item
25Air mix damper motor (MAX. HOT)When damper is moved to MAX.
COOL positionAlmost no voltage
(0.5 V)
When damper is moved to MAX. HOT
position10 V
26Inside/outside air changeover damper
motor (Outside)When switch is set to inside air
position10 V
When switch is set to outside air
positionAlmost no voltage
(0.5 V)
28IG2 power supplyWhen ignition switch is ONSystem voltage
29EarthAt all timesContinuity
30ILL power supplyWhen lighting switch is at ONSystem voltage
34A/C outputWhen A/C is OFF0 V
When A/C is ONSystem voltage
35EarthAt all timesContinuity
ON-VEHICLE SERVICE
REFRIGERANT CHARGING, LEVEL CHECK,
ADDITION AND REMOVAL, PERFORMANCE
TEST, DUAL PRESSURE SWITCH SIMPLE
CHECK
Follow the same procedures as for the heater and manual
air conditioner. (Refer to P.55-6.)
Page 447 of 558
FULL-AUTOMATIC AIR CONDITIONER – On-vehicle Service55-57
POWER RELAY CHECK
Follow the same procedures as for the heater and manual
air conditioner except for the following. (Refer to P.55-13.)
BLOWER HIGH SPEED RELAY
Battery voltageTerminal No.
1234
Power is not supplied
Power is supplied
IDLE-UP OPERATION CHECK
The idle-up inspection procedures are the same as for the
heater and manual air conditioner. (Refer to P.55-14.)
Standard value: 750 ± 50 r/min
Standard value: 850 ± 50 r/min
NOTE
If the idling speed is not within the standard value range,
adjust it.
Blower high speed relay
Page 453 of 558

FULL-AUTOMATIC AIR CONDITIONER –
Heater Water
Temperature Sensor55-63
HEATER WATER TEMPERATURE SENSOR
REMOVAL AND INSTALLATION
Pre-removal and Post-installation Operation
Floor Console Removal and Installation
Glove Box Removal and Installation
Foot Duct Removal and Installation
(Refer to P55-31.)
1 2
Removal steps
AA1. Heater water temperature sensor clip
AA2. Heater water temperature sensor
REMOVAL SERVICE POINT
AHEATER WATER TEMPERATURE SENSOR CLIP
AND HEATER WATER TEMPERATURE SENSOR
REMOVAL
Pull out the heater water temperature sensor clip which is
at the bottom of the heater unit, and then remove the heater
water temperature sensor from the heater unit.
INSTALLATION SERVICE POINT
AHEATER WATER TEMPERATURE SENSOR AND
HEATER WATER TEMPERATURE SENSOR CLIP
INSTALLATION
Insert the heater water temperature sensor into its mounting
hole at the bottom of the heater unit, and then fix it by inserting
the heater water temperature sensor clip.
Heater unit
Heater water
temperature
sensor clip
Page 454 of 558
FULL-AUTOMATIC AIR CONDITIONER –
Heater Water Temperature Sensor /
Other Maintenance Service Points55-64
INSPECTION
Follow the same procedure as for the inspection of the outside
temperature sensor. (Refer to P55-62.)
OTHER MAINTENANCE SERVICE POINTS
The following maintenance service points are the same as for the manual A/C.
ItemsReference page
Dual Pressure Switch55-13
Blower Relay, A/C Compressor Relay, Condenser Fan Relay, Radiator Fan Relay55-13, 14
Idle-up System55-14
Heater Unit, Cooling and Blower Unit55-15
Blower Motor Assembly, Evaporator55-19
Compressor, Tension Pulley55-23
Condenser, Condenser Fan55-28
Ducts55-31