CHASSIS ELECTRICAL – Ignition Switch and Immobilizer System54-18
Inspection Procedure 4
Malfunction of the immobilizer-ECU power supply and earth circuit
Measure at the immobilizer-ECU con-
nector B-100.
Disconnect the connector and
measure at the harness side.
(1) Voltage between 2 and body earth
(Ignition switch: ON)
OK: System voltage
(2) Voltage between 1 and body earth
OK: System voltage
(3) Continuity between 8 and body earth
OK: Continuity(1) NGCheck the following connectors:
B-76, B-74, B-100NG
Repair
OK
Check trouble symptoms.
NG
Check the fuse and the harness wire
between the ignition switch (IG) and
immobilizer-ECU.NG
OK
Check trouble symptoms.NGCheck the ignition switch.
(Refer to P.54-20.)
(2) NG
Check the following connectors:
B-65, B-100NG
Repair
OK
Check trouble symptoms.NGCheck the harness wire between the
immobilizer-ECU and the engine control
relay, and repair if necessary.
(3) NG
Check the following connectors.
B-50, B-100NG
Repair
OK
Check trouble symptoms.NGCheck the harness wire between the
immobilizer-ECU and body earth, and
repair if necessary. Repair
CHECK AT IMMOBILIZER-ECU
TERMINAL VOLTAGE CHECK CHART
Terminal No.SignalChecking requirementsTerminal voltage
1Immobilizer-ECU power supplyIgnition switch: ONSystem voltage
2Ignition switch-IGIgnition switch: OFF0V
Ignition switch: ONSystem voltage
8Immobilizer-ECU earthAlways0V