1999 AUDI A6 01E Transmission Bearing House And Torsen Differential Workshop Manual

Page 33 of 38

AUDI A6 1999 C5 / 2.G 01E Transmission Bearing House And Torsen Differential Workshop Manual 34-84
 
    
-  Guide oil collector from interior of end cover with support arm leading 
through hole of end cover (arrow), until O-ring can be fitted from 
outside onto oil collector. 
-  Lightly oil

Page 34 of 38

AUDI A6 1999 C5 / 2.G 01E Transmission Bearing House And Torsen Differential Workshop Manual 34-85
      
-  Install complete selector shaft.
    
-  Screw locking bolts -A- for selector shaft into transmission housing.
-  Aluminium and steel bolts must not be interchanged when installing.

Page 35 of 38

AUDI A6 1999 C5 / 2.G 01E Transmission Bearing House And Torsen Differential Workshop Manual 34-86
       The following shims are available:  
     
Measured range 
mm  Qty.  
Shim thickness 
(mm)  
7.05-7.30   1  
1  
1  1.65  
1.45  
1.20  
7.30-7.55   1  
1  
1  1.65  
1.45  
0.95  
7.55-7

Page 36 of 38

AUDI A6 1999 C5 / 2.G 01E Transmission Bearing House And Torsen Differential Workshop Manual 8.50-8.75   1  
1  1.65  
1.20  
8.75-9.00   1  
1  1.65  
0.95  
9.00-9.25   1  
1  1.65  
0.70  
9.25-9.50   1  
1  1.65  
0.45  
Pa
ge 36 of 38 Bearin
g housin
g, Torsen differential, end cover, in

Page 37 of 38

AUDI A6 1999 C5 / 2.G 01E Transmission Bearing House And Torsen Differential Workshop Manual 34-87
 
    
-  Insert spring plate -C- into bearing housing.
   Installation position: larger diameter (concave side) towards the shims.
-  Fit shims -B- as determined in table. 
-  Fit spring -A- to

Page 38 of 38

AUDI A6 1999 C5 / 2.G 01E Transmission Bearing House And Torsen Differential Workshop Manual 34-88
      
-  Remove protective hose.
     
-  Install release bearing, clutch release lever and 
guide sleeve   from Page 30
-27
 . 
     
-  Check that transmission can be shifted through 
all gea