1998 SSANGYONG MUSSO transmission oil

[x] Cancel search: transmission oil

Page 1007 of 1463

SSANGYONG MUSSO 1998  Workshop Repair Manual 5A-30  AUTOMATIC TRANSMISSION
Solenoid Valve Symbols (On/off Solenoids)
The solenoid symbol shown adjacent to each solenoid on the
hydraulic system schematics indicates the state of the oil flow
throu

Page 1008 of 1463

SSANGYONG MUSSO 1998  Workshop Repair Manual AUTOMATIC TRANSMISSION  5A-31
K-Line
The K-line is typically used for obtaining diagnostic information from the TCU. A computer with a special interface is
connected to the TCU and all current faults,

Page 1011 of 1463

SSANGYONG MUSSO 1998  Workshop Repair Manual 5A-34  AUTOMATIC TRANSMISSION
Figure 3.10 - Manual Valve
1-2 Shift Valve
The 1-2 shift valve (refer to figure 3.11) is a two position valve that must be switched to the (2,3,4) position in order to
ge

Page 1012 of 1463

SSANGYONG MUSSO 1998  Workshop Repair Manual AUTOMATIC TRANSMISSION  5A-35
2-3 Shift Valve
The 2-3 shift valve (refer to figure 3.12) is a two position valve. It is used on all 2-3 and 3-2 gearshifts.
The switching of this valve is achieved by S

Page 1013 of 1463

SSANGYONG MUSSO 1998  Workshop Repair Manual 5A-36  AUTOMATIC TRANSMISSION
4-3 Sequence Valve
The 4-3 sequence valve (refer figure 3.14) is a two position spring loaded valve. It switches during 3-4 and 4-3
gearshifts although it performs no fun

Page 1014 of 1463

SSANGYONG MUSSO 1998  Workshop Repair Manual AUTOMATIC TRANSMISSION  5A-37
Figure 3.16 - Clutch Apply Regulator Valve
Clutch Apply Regulator Valve
The clutch apply regulator valve (refer figure 3.16) is a fixed ratio valve. This valve provides a

Page 1015 of 1463

SSANGYONG MUSSO 1998  Workshop Repair Manual 5A-38  AUTOMATIC TRANSMISSION
Reverse Lockout Valve
The reverse lockout valve (refer figure 3.18) is a two position valve contained in the upper valve body. This valve
uses 51-52 pressure as a signal

Page 1016 of 1463

SSANGYONG MUSSO 1998  Workshop Repair Manual AUTOMATIC TRANSMISSION  5A-39
Primary Regulator Valve
The primary regulator valve (PRV) (refer to figure 3.19) regulates the transmission line pressure (or pump output
pressure). This valve gives eith