Page 22 of 73

c11010.0
AIR CONDITIONING
Fault finding - Interpretation of XR25 bargraphs62
KANGOO
ALL TYPES
Enter G0** on the XR25.
Check that the system operates correctly.AFTER
REPAIR
4
CONT 1
YES
NO
Check that 12 volts is present on track 1 of the clutch connector.
Is 12 volts present?
Check the condition of the compressor earth.
Is the compressor earth in good condition?
YES Check the continuity and absence of short circuits of the electrical
wiring between the clutch and the compressor.
If the electrical wiring is faulty, repair it.
If the electrical wiring is in good condition, change the compressor.
NO Repair the compressor earth.
Check the continuity and absence of short circuits of the electrical wiring
between track 1 of the clutch and tracks 2 and 17 of the air conditioning control
unit 30-way connector.
Repair the electrical wiring if necessary.
For petrol vehicles:
Use the XR25 fiche which corresponds to the vehicle.
With the engine running, operate the AC then check on the XR25 fiche whether
the "Compression authorised or prohibited" status bargraph is illuminated.
Is the bargraph illuminated?
YES Check and repair the electrical wiring.
NO Refer to Left-hand bargraph 4 illuminated, cont 2.
62-11
Page 23 of 73

c11010.0
AIR CONDITIONING
Fault finding - Interpretation of XR25 bargraphs62
KANGOO
ALL TYPES
Enter G0** on the XR25.
Check that the system operates correctly.AFTER
REPAIR
4
CONT 2
YES
NO
For petrol vehicles:
Use the XR25 injection fiche which corresponds to the vehicle.
With the engine running, operate the AC then check on the XR25 fiche whether the " AC authorisation"
status bargraph is illuminated.
Is the bargraph illuminated?
There is a problem at the injection end.
Refer to the injection fault finding procedure which corresponds to the vehicle.
Check the continuity and absence of short circuits of the electrical wiring.
Repair if necessary.
Check that 12 volts is present on tracks 2 and 17 of the air conditioning control
unit 30-way connector.
Is 12 volts present?
YES There is a problem at the injection end.
Refer to the injection fault finding procedure which corresponds to
the vehicle.
NO Check whether the evaporator temperature sensor is in place.
Check its resistance: disconnect the evaporator temperature sensor
and measure the resistance at its terminals. The resistance measured
should be between 90 ohms and 13.7 kohms.
If the evaporator temperature sensor is in good condition, change
the air conditioning control unit.
If the evaporator temperature sensor is not in good condition,
change it.
62-12
Page 28 of 73

c11010.0
AIR CONDITIONING
Fault finding - Interpretation of XR25 bargraphs62
KANGOO
ALL TYPES
Check that the system operates correctly.AFTER
REPAIR
Left-hand bargraph 13 illuminated
AIR CONDITIONING PROHIBITED BY INJECTION
13
NOTES
Fiche n° 61
This bargraph should be extinguished when the engine is running.
If it is illuminated, you can begin the fault finding procedure.
First check that the air conditioning has been selected (selection on the control panel).
Check the continuity of the electrical wiring between track 5 of the injection computer and track 13 of
the air conditioning control unit 30-way connector (P.A. information).
Repair it if necessary.
Check the continuity of the electrical wiring between:
- track 51 of the injection computer and track 18 of the AC computer 30-way connector for D7F and E7J
engines,
- track 19 of the injection computer and track 18 of the AC computer 30-way connector for F8Q engines.
Repair it if necessary.
If the problem persists, check the injection fault finding procedure, as it is a problem related to the
injection.
62-17
Page 34 of 73
c11010.0
AIR CONDITIONING
Fault finding charts
62
KANGOO
ALL TYPES
Check that the components which were removed are connected correctly.
Check that the system operates correctly.AFTER
REPAIR
yes
CHART 3
CONT
A
noChange the thermostat.
yes
yes
noEnd of fault finding.
noEnd of fault finding.
With the engine cold, remove the engine
coolant thermostat and check that it is not
jammed in the open position.
Is it correct?
Check that there is no unwanted intake of
cold air into the passenger compartment
(seals, grommets, cables ...).
Repair if necessary
Does the fault persist?
Check the air inlets (particle filter)
and outlets.
Partially blocked air inlets or outlets
reduce the flow of heated air
into the
passenger compartment.
Repair if necessary.
Does the fault persist?
The heater radiator must be blocked. Remove
the radiator and clean or change it
(only valid for vehicles which have been
driven without the particle filter).
62-23
Page 36 of 73
c11010.0
AIR CONDITIONING
Fault finding charts
62
KANGOO
ALL TYPES
Check that the system operates correctly.AFTER
REPAIR
yes
CHART 5TOO HOT
NOTES
noSee CHART 1.
noReadjust the cable
(to the right of the air distribution unit).
yes
yesSee CHART 11.
no
Before carrying out any work, check that the customer uses the air conditioning
correctly.
Non regulated air conditioning.
Visually check that moving the control
moves the mixing flap.
Does it move?
Check that the flap travel
is complete.
Is the travel complete?
Check the operation
of the recirculation flap.
Is it jammed in the recirculation position?
Check the operation
of the engine coolant thermostat.
Change the thermostat if necessary.
62-25
Page 48 of 73

c11010.0
AIR CONDITIONING
Fault finding charts
62
KANGOO
ALL TYPES
AFTER
REPAIR
CHART 14AIR CONDITIONING PROBLEMS
Performance poor
NOTES
noSee CHART 14A.
noEnd of fault finding.
noSee CHART 11.
noEnd of fault finding.
Is it an air flow problem?yesSee CHART 2 or CHART 9.
no
A
yes
yes
yes
Before carrying out any work, check that the customer uses the air conditioning
correctly.
Non regulated air conditioning.
Check that the compressor operates, with the
air conditioning on, passenger compartment
ventilation on maximum in recirculation
mode, engine running at idle.
Does the compressor operate?
Check the tension of the compressor belt, the
clutch air gap and its condition.
Retension the belt or change
the compressor clutch.
Does the fault persist?
yes
Ensure that the recirculation flap is in the
recirculation position in air conditioning
recirculation mode.
Is it in this position?
Check that the flap travel is complete,
readjust the cable if necessary.
Does the fault persist?
Check that the components which were removed are connected correctly.
Check that the system operates correctly.
62-37
Page 49 of 73
yes
c11010.0
CONDITIONING
Fault finding charts
62
KANGOO
ALL TYPES
AFTER
REPAIR
CHART 14
CONT
noTop up the coolant circuit.
yes
noSee CHART 15.
Change the pressure sensor.
Check the cleanness of the
condenser wiring harness.
Clean or change the condenser.
If the fault persists, check the operation of
the cooling fan assembly at high speed
(ventilation and air conditioning
on maximum).
It should be:
- operating if high pressure≥ 20 bars
- stopped if high pressure≤ 15 bars
Is the operation of the fan assembly normal?
Check that the components which were removed are connected correctly.
Check that the system operates correctly.
A
With the vehicle stationary, engine running
at idle, air conditioning on maximum,
measure the pressure of the coolant circuit.
If the pressure is > 28 bars, there is :
- too much fluid,
- or the operation of the fan assembly is ab-
normal,
- or the condenser is clogged,
- or the engine heats up too much.
Is the pressure < 28 bars ?
62-38
Page 50 of 73

yes
Check the electrical wiring:
air 9 1 pressure
conditioning 10 4 sensor
computer 11 3 connector
and between the connector and the sensor.
Is the wiring in good condition?
c11010.0
AIR CONDITIONING
Fault finding charts
62
KANGOO
ALL TYPES
AFTER
REPAIR
CHART 14AAIR CONDITIONING PROBLEMS
Performance poor
NOTES
yesSee CHART 14.
no
no
If the fault persists,
change the compressor.
yes
noRepair the faulty
electrical wiring.
yes
noTop up the coolant circuit.
Change the pressure sensor.
Before carrying out any work, check that the customer uses the air conditioning
correctly.
Non regulated air conditioning.
With the air conditioning and ventilation on
maximum and the engine running at idle,
check that the compressor operates.
Does the compressor operate?
Connect the XR25 and enter G21*
(direct compressor control).
Does the compressor operate?
Check the pressure of the coolant circuit.
The compressor should cut in for:
- low pressure≥ 2 bars,
- high pressure≤ 28 bars.
Is this correct?
Check the wiring between
the heating and ventilation computer
and the compressor clutch.
Repair if necessary.
Check that the components which were removed are connected correctly.
Check that the system operates correctly.
62-39