1998 JAGUAR X308 SOLENOID

[x] Cancel search: SOLENOID

Page 1398 of 2490

JAGUAR X308 1998 2.G Workshop Manual  
Connector Pin Identity Chart for GB001 
 
Connector Pin Identity Chart for EM044 
Pin NumberCircuitCircuit Function
001DLS position W3
002Power ground (common to TCM)
003Ignition B+
004Neutral (BPU)

Page 1399 of 2490

JAGUAR X308 1998 2.G Workshop Manual  
 
 
Pin NumberCircuitCircuit Function
001n3 speed signal
002Pressure regulator MD signal
003n2 speed signal
004Temperature sensor
005Solenoid 1 <-> 2, 4 <-> 5
006Solenoid and pressure regulator +ve

Page 1400 of 2490

JAGUAR X308 1998 2.G Workshop Manual Automatic Transmission/Transaxle - 4.0L SC V8 - AJ26 - Diagnostic 
Strategy 
Diagnosis and Testing 
Symptom Chart 
Symptom Chart 
Special Tool(s)
 
Digital multimeter 
 
Generic scantool 
SymptomPossi

Page 1401 of 2490

JAGUAR X308 1998 2.G Workshop Manual Pinpoint test A: P0740 
DTC P0730 Incorrect gear ratioEngaged gear implausible / transmission 
slipping  Oil level low 
Valve body assembly faulty 
Transmission faulty 
*
*
*
*GO to Pinpoint Test H  *

Page 1408 of 2490

JAGUAR X308 1998 2.G Workshop Manual  With EM062 and GB001 disconnected, measure the 
resistance between EM062/038 and EM008R 1 
Is the resistance > 10 MOHM? 
Yes GO to C5  
No  Inspect EM062 for corrosion, bent / pushed back pins or 
lo

Page 1411 of 2490

JAGUAR X308 1998 2.G Workshop Manual With EM062 and GB001 disconnected, measure the 
resistance between EM062/014 and EM008R 1 
Repeat for EM062/015 and EM008R 2 
EM062/016 and EM008R 3 
Is the resistance > 10 MOHM? 
Yes GO to C8  
No  I

Page 1464 of 2490

JAGUAR X308 1998 2.G Workshop Manual Automatic Transmission/Transaxle External Controls - 4.0L NA V8 - 
AJ27/3.2L NA V8 - AJ26  - External Controls 
Description and Operation 
Introduction 
Driver gearshift control is effected by: 
Th

Page 1465 of 2490

JAGUAR X308 1998 2.G Workshop Manual The Drive-to-fourth switch: 
Detects when the gear selector lever is moved from Drive to Fourth.  Is hard-wired to the transmission control module.  
The Neutral position switch: 
Is hard-wir