1998 DODGE RAM 1500 system

[x] Cancel search: system

Page 2559 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (1) Disconnect and isolate the battery negative
cable.
(2) Recover the refrigerant from the refrigerant
system (Refer to 24 - HEATING & AIR CONDITION-
ING/PLUMBING - STANDARD PROCEDURE -
REFRIGERANT R

Page 2560 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (7) Remove the tape or plugs from the suction and
discharge line fittings and the compressor ports.
(8) Lubricate new rubber O-ring seals with clean
refrigerant oil and install them on the suction and

Page 2562 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual EMISSIONS CONTROL
TABLE OF CONTENTS
page page
EMISSIONS CONTROL
DESCRIPTION
DESCRIPTION - STATE DISPLAY TEST
MODE...............................1
DESCRIPTION - CIRCUIT ACTUATION TEST
MODE.............

Page 2563 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual DESCRIPTION - MONITORED SYSTEMS
There are new electronic circuit monitors that
check fuel, emission, engine and ignition perfor-
mance. These monitors use information from various
sensor circuits to i

Page 2564 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual Immediately after a cold start, between predeter-
mined temperature thresholds limits, the three port
solenoid is briefly energized. This initializes the
pump by drawing air into the pump cavity and a

Page 2565 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual O2S is used to detect the amount of oxygen in the
exhaust gas before the gas enters the catalytic con-
verter. The PCM calculates the A/F mixture from the
output of the O2S. A low voltage indicates hi

Page 2566 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual OPERATION
OPERATION
The Powertrain Control Module (PCM) monitors
many different circuits in the fuel injection, ignition,
emission and engine systems. If the PCM senses a
problem with a monitored circ

Page 2567 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual For example, when the MIL is illuminated for an
Oxygen Sensor fault, the Task Manager does not run
the Catalyst Monitor until the Oxygen Sensor fault is
remedied. Since the Catalyst Monitor is based o