DODGE RAM 1500 1998 2.G Workshop Manual STANDARD PROCEDURE - REFRIGERANT
RECOVERY
WARNING: REVIEW THE WARNINGS AND CAU-
TIONS IN THE FRONT OF THIS SECTION BEFORE
PERFORMING THE FOLLOWING OPERATION (Refer
to 24 - HEATING & AIR CONDITIONING/P

Page 2535 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual After the system has been tested for leaks and
evacuated, a refrigerant (R-134a) charge can be
injected into the system.
NOTE: When connecting the service equipment
coupling to the line fitting, verif

Page 2536 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual when a minimum discharge pressure of 2756 kPa
(400 psi) is reached.
The high pressure relief valve vents only enough
refrigerant to reduce the system pressure, and then
re-seats itself. The majority o

Page 2538 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual INSTALLATION
NOTE: If a replacement compressor is being
installed, be certain to check the refrigerant oil
level. See Refrigerant Oil Level in this group for the
procedures. Use only refrigerant oil o

Page 2539 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (11) Install the serpentine drive belt (Refer to 7 -
COOLING/ACCESSORY DRIVE/DRIVE BELTS -
INSTALLATION).
(12) Reconnect the battery negative cable.
(13) Evacuate the refrigerant system (Refer to 24 -

Page 2540 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual REMOVAL - 5.9L DIESEL ENGINE
WARNING: REVIEW THE WARNINGS AND CAU-
TIONS IN THE FRONT OF THIS SECTION BEFORE
PERFORMING THE FOLLOWING OPERATION (Refer
to 24 - HEATING & AIR CONDITIONING/PLUMBING -
WAR

Page 2541 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (4) Align the condenser lower mounting tabs to the
mounting flanges.
(5) Install the two bolts that secure the condenser/
cooling fan assembly to the upper front crossmember.
Tighten the bolts to 10.5

Page 2542 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (10) Connect the discharge line to the condenser
inlet port.
(11) Install and tighten the nut that secures the
discharge line fitting to the condenser. Tighten the
nut to 20 N´m (180 in. lbs.).