1998 DODGE RAM 1500 seats

[x] Cancel search: seats

Page 1252 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (5) The valve seat and valve face must maintain a
face angle of 44.5 - 45 É angle (Fig. 17).
REMOVAL
NOTE: The cylinder heads must be removed in
order to perform this procedure.
(1) Remove rocker arm

Page 1253 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual TESTING VALVE SPRINGS
NOTE: Whenever the valves are removed from the
cylinder head it is recommended that the valve
springs be inspected and tested for reuse.
Inspect the valve springs for physical si

Page 1257 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual INSTALLATION
NOTE: The cylinder head bolts are tightened using
a torque plus angle procedure. The bolts must be
examined BEFORE reuse. If the threads are necked
down the bolts should be replaced.
Neck

Page 1271 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (3) Using Special Tools 8349 Crankshaft Rear Oil
Seal Installer and C-4171 Driver Handle (Fig. 42),
with a hammer, tap the seal into place. Continue to
tap on the driver handle until the seal installe

Page 1311 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual ENGINE - 4.7L
TABLE OF CONTENTS
page page
ENGINE - 4.7L
DIAGNOSIS AND TESTING
DIAGNOSIS AND TESTING - ENGINE
DIAGNOSIS - PERFORMANCE...........90
DIAGNOSIS AND TESTING - ENGINE
DIAGNOSIS - MECHANICAL.

Page 1315 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual DIAGNOSIS AND TESTING - ENGINE DIAGNOSIS - MECHANICAL
CONDITION POSSIBLE CAUSES CORRECTIONS
NOISY VALVES 1. High or low oil level in
crankcase.1. (Refer to LUBRICATION &
MAINTENANCE -
SPECIFICATIONS)

Page 1334 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (15) Lock the secondary timing chains to the idler
sprocket using Special Tool 8515 (Fig. 15).
NOTE: Mark the secondary timing chain prior to
removal to aid in installation.
(16) Mark the secondary ti

Page 1335 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual INSTALLATION
INSTALLATION - LEFT CYLINDER HEAD
NOTE: The cylinder head bolts are tightened using
a torque plus angle procedure. The bolts must be
examined BEFORE reuse. If the threads are necked
down