1998 DODGE RAM 1500 Head bolt

[x] Cancel search: Head bolt

Page 498 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (2) Apply a small amount of engine oil to sensor
o-ring.
(3) Install sensor into cylinder head with a slight
rocking action. Do not twist sensor into position as
damage to o-ring may result.
CAUTION:

Page 501 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (4) Remove coil mounting nut from mounting stud
(Fig. 17).
(5) Carefully pull up coil from cylinder head open-
ing with a slight twisting action.
(6) Remove coil from vehicle.
5.7L V-8
Before removing

Page 502 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual Knock sensors contain a piezoelectric material
which constantly vibrates and sends an input voltage
(signal) to the PCM while the engine operates. As the
intensity of the crystals vibration increases

Page 570 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (2) Remove the left instrument panel bezel. (Refer
to 23 - BODY/INSTRUMENT PANEL/CLUSTER
BEZEL - REMOVAL).
(3) Disconnect the harness connector.
(4) Remove the screws that secure the headlamp
switch t

Page 571 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (3) Install the bolts attaching headlamp unit to the
fender (Fig. 11).
(4) Align the seal and install the push pins.
(5) Connect the battery negative cable.
ADJUSTMENTS
Headlamps can be aligned using

Page 1220 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (3) Connect the electrical connectors by pushing
straight on and rotating the connector arm inboard,
until the connector is firmly locked in place on the
module assembly.
(4) Grasp the integrated powe

Page 1239 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual OIL PRESSURE
SPECIFICATION SPECIFICATION
Metric Standard
At Curb Idle
Speed (MIN)*25 kPa 4 psi
@ 3000 rpm 170 - 758 kPa 25 - 110 psi
* CAUTION: If pressure is zero at curb idle, DO
NOT run engine at 3

Page 1244 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual AIR CLEANER ELEMENT
REMOVAL
Filter Element Only
Housing removal is not necessary for element (fil-
ter) replacement.
(1) Loosen clamp (Fig. 3) and disconnect air duct
at air cleaner cover.
(2) Pry ove