DODGE RAM 1500 1998 2.G Workshop Manual SKIM cannot be repaired and, if faulty or damaged,
the unit must be replaced.
DIAGNOSIS AND TESTING
VEHICLE THEFT SECURITY SYSTEM
WARNING: ON VEHICLES EQUIPPED WITH AIR-
BAGS, REFER TO RESTRAINT SYSTE

Page 1857 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual CONDITION POSSIBLE CAUSES CORRECTION
NO 3-4 UPSHIFT 1. O/D Switch In OFF Position. 1. Turn control switch to ON position.
2. Overdrive Circuit Fuse Blown. 2. Replace fuse. Determine why fuse failed
an

Page 1963 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual STATOR
Torque multiplication is achieved by locking the
stators over-running clutch to its shaft (Fig. 234).
Under stall conditions the turbine is stationary and
the oil leaving the turbine blades st

Page 1964 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (6) Check converter seating with a scale and
straightedge (Fig. 235). Surface of converter lugs
should be 19mm (0.75 in.) to the rear of the straight-
edge when converter is fully seated.
(7) If neces

Page 2497 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual and coil are the only serviced parts on the compres-
sor.
A/C compressor clutch engagement is controlled by
several components: the A/C-heater control, A/C pres-
sure transducer, A/C compressor clutch

Page 2503 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual The A/C pressure transducer cannot be adjusted or
repaired and, if faulty or damaged, it must be
replaced.
OPERATION
The A/C pressure transducer monitors the pres-
sures in the high side of the refrig

Page 2521 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual INSTALLATION
(1) Install the floor distribution duct onto the bot-
tom of the HVAC housing.
(2) Install the five screws that secure the floor dis-
tribution duct to the HVAC housing. Tighten the
screw

Page 2523 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual ING/CONTROLS/BLOWER MOTOR RESISTOR
BLOCK - INSTALLATION).
(5) If removed, install the blower motor (Refer to
24 - HEATING & AIR CONDITIONING/DISTRIBU-
TION/BLOWER MOTOR - INSTALLATION).
(6) Install th