Page 1466 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (8) Replace injector o-ring and sealing washer on
injectors #5 and #6. Install injectors and torque using
the following steps:
²Step 1ÐInstall injector hold-down capscrews
and torque to 5 N´m (44 i

Page 1495 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (6) Remove the wooden dowel rods and rubber
bands from the tappets.
(7) Lubricate the push rods with engine oil and
install in their original location.Verify that they
are seated in the tappets.
(8) L

Page 1508 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (4) The top surface of all of the rings are identified
with the word TOP or the suppliers MARK. Assem-
ble the rings with the word TOP or the suppliers
MARK up.
(5) Position the oil ring expander in

Page 1592 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (5) Position APPS assembly to bottom of battery
tray and install 3 bolts. Refer to Torque Specifica-
tions.
(6) Install wheelhouse liner. Refer to Body.
(7)The 5.7L V-8 engine is equipped with a
fully

Page 1593 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual The sensor is a hall effect device combined with an
internal magnet. It is also sensitive to steel within a
certain distance from it.
A tonewheel (targetwheel) is bolted to the engine
crankshaft (Fig.

Page 1597 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual REMOVAL
The fuel pump relay is located in the Power Distri-
bution Center (PDC) (Fig. 13). Refer to label on PDC
cover for relay location.
(1) Remove PDC cover.
(2) Remove relay from PDC.
(3) Check co

Page 1598 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual IAC Stepper Motor Program:The PCM is also
equipped with a memory program that records the
number of steps the IAC stepper motor most recently
advanced to during a certain set of parameters. For
exampl

Page 1605 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual INSTALLATION
Threads of new oxygen sensors are factory coated
with anti-seize compound to aid in removal.DO
NOT add any additional anti-seize compound to
threads of a new oxygen sensor.
(1) Install O2