Page 990 of 1310

10
2.
Exit conditions from the adjustment mode
The ETACS-ECU cancels the adjustment mode when any of the following conditions is satisfied:
•
Diagnosis control: OFF (Disconnect the MUT-II>)
•
Key reminder switch: ON (Pull out the ignition key.)
•
Ignition switch: Other than LOCK (OFF)
•
Door switch: ON (Open the door)
•
After the ETACS_ECU has entered the adjustment mode, no adjustment is made within 3 minutes (If
any adjustment is made within 3 minutes, the ETACS-ECU monitors an adjustment operation for
other 3 minutes.
•
Other warning buzzer(s) sounds
3.
Adjustment of functions
Function Adjustment procedure
Keyless entry answerback function When the transmitter lock switch is turned on twice continuously
within 2 seconds, the lock answerback function toggles on and off.
•
If the function toggles on, the buzzer sounds once (default con-
dition).
•
If the function toggles off, the buzzer sounds twice,
When the transmitter unlock switch is turned on twice continuously
within 2 seconds, the unlock answerback function toggles on and
off.
•
If the function toggles on, the buzzer sounds once (default con-
dition).
•
If the function toggles off, the buzzer sounds twice,
Initialisation of all the ETACS func-
tions (From deactivation to activa-
tion)When the tailgate switch remains on for more than 20 seconds, th
buzzer sounds twice and he answer-back function of the keyless
entry system is initialised.
The buzzer will sound in 10 seconds (indicating that the ETACS-
ECU enters the adjustment mode), but the washer switch must re-
mains off for 20 seconds in order to initialise all the functions.
If the tailgate switch remains on for more than 20 seconds without
entering the adjustment mode, the system enters the adjustment
mode in 10 seconds, but does not initialise all of the functions.
INSPECTION CHART FOR TROUBLE SYMPTOMS
Trouble symptom Inspection procedure No. Reference page
None of the doors can be locked or unlocked using th
transmitter.142-3
All of the doors can be locked and unlocked using th
transmitter, but the room lamp or turn-signal lamp does
not flash or illuminate. (However, the room lamp oper-
ates normally when the doors are opened and closed.)242-4
Encrypted codes cannot be registered. 3 42-5
42-2BODY – Keyless entry system
Page 992 of 1310

12From previous page
Key reminder switch continuity check
OK NG
MUT-II Pulse Check
•
Key reminder switch input signal
OK:
MUT-II buzzer sounds once when removing
and inserting ignition key.NG
Repair
OK
Check the following connectors:
C-72, C-79, C-86, C-91
Replace the transmitter.OK NG
OK
Check trouble symptomsRepair
Check the trouble symptoms.NG
OK
Replace the ETACS-ECU.
Check the harness wire, and repair if necessary.
•
Between key reminder switch and ETACS-ECU
•
Between key reminder switch and earth
INSPECTION PROCEDURE 2
All of the doors can be locked and unlocked using th
transmitter, but the room lamp or turn-signal lamp does
not flash or illuminate. (However, the room lamp oper-
ates normally when the doors are opened and closed.)Probable cause
If neither room lamp nor turn-signal lamp flash/illuminate, the
cause may be a malfunction of the ETACS-ECU or driver’s-side
door lock actuator.
If either room lamp or turn-signal lamp does not flash/illuminate,
the cause may be a malfunction of the room lamp circuit or turn-
signal lamp.•
Malfunction of ETACS-ECU
•
Malfunction of driver’s door lock actuator
•
Burnt turn-signal lamp bulb
•
Malfunction of connector or wiring harness
Carry out the troubleshooting for room lamp circuit.Does the room lamp go on/go off simultaneous
with opening/closing door?NO
Yes
Does the turn-signal lamp flash when the turn-
signal lamp switch is operated?NO
Carry out the troubleshooting for turn-signal lamp
circuit.
Yes
NG
Check the driver’s door lock actuator
OK NG
MUT-II Pulse Check
•
Drivers door lock actuator switch input signal
OK:
MUT-II buzzer sounds once when locking
or unlocking driver’s door.Replace
OKCheck the following connectors:
C-38, C-110, E-09 ,
E-20
Replace the ETACS-ECUOK NG
Check trouble symptoms.Repair
NG
Check the harness wire, and repair if necessary.
•
Between ETACS-ECU and driver’s door lock actua-
tor
•
Between driver’s door lock actuator and earth
42-4BODY – Keyless Entry System
Page 1090 of 1310

8
SEALANT
Item Specified sealant Remark
Sensor cable 3M ATD Part No. 8625 or equivalent Ribbon sealer
TROUBLESHOOTING
STANDARD FLOW OF DIAGNOSTIC TROUBLESHOOTING
Refer to GROUP 00 – How to Use Troubleshooting/Inspection Service Points.
DIAGNOSIS FUNCTION
DIAGNOSIS CODE CHECK
Connect the MUT-II
to the diagnosis connector (16 –pin) under the instrument under cover, then check diagnosis codes.
(Refer to GROUP 00 – How to Use Troubleshooting/Inspection Service Points.)
ERASING DIAGNOSIS CODES
Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points.
INSPECTION CHART FOR DIAGNOSIS CODES
Inspect according to the inspection chart that is appropriate for the malfunction code.
Code No. Diagnosis ItemReference Page
11, 12, 13 Front impact sensor system 52B-7
21, 22 Air bag module (squib) system 52B-8
31, 32 SDU capacitor system 52B-9
33* Cranking signal system 52B-10
34* Connector lock system 52B-11
41* IG1 (A) power circuit system 52B-11
42* IG1 (B) power circuit system 52B-12
43 SRS warning lamp drive circuit system
Lamp does not illuminate*52B-13
SRS warning lamp drive circuit system
Lamp does not switch off52B-14
44 SRS warning lamp drive circuit system 52B-14
45 SDU non-volatile memory (EEPROM) and A/D converter system 52B-14
NOTE
(1) *: If the vehicle condition returns to normal, the diagnosis code will be automatically erased, and the SRS warning lamp will
return to normal.
(2) If the vehicel has a discharged battery it will store the fault codes 41 or 42. When these diagnosis codes are displayed, check
the battery.
52B-6SRS – Sealant/Troubleshooting
52400060015
WHEN USING THE MUT-II
Connect the MUT-II to the diagnosis connector and erase the diagnosis code.
Caution
Turn off the ignition switch before connecting or disconnecting the MUT-II.
52400310097
52400320063
52400330123