Page 41 of 43
01-111
 
    
Display on VAS5051:  
Note:  
Secondary Air Injection (AIR) system test lasts approx. 60 seconds.  -  Depress gas pedal completely (swiftly) and then release it (brief 
acceleration of at least 2500 RPM). 
-  Check specified value in display field -4-.
Pa
ge 41 of 43 Readiness code11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.01.7 
         
        
        
     
        
        Page 42 of 43
01-112
 
  
Display fields  
  
1   2   3   4  
Display group 077: Secondary Air Injection (AIR) system diagnostic (Bank 1)  
Display  xxxx/min  xx.x 
g/s  xx %  
---  
Indicated  Engine speed 
(RPM)  Air 
mass  Relative air mass bank 1, 
Secondary Air Injection (AIR) 
system  Diagnostic condition  
Functional 
range          
Test OFF  
Test ON  
System OK  
System not OK  
Aborted  
Specified 
value  FWD: 740 to 
860 RPM  
AWD: 760 to 
880 RPM  2 to 5 
g/s  more than -20 %   System OK  
Note  
  
    
If "System not OK" is displayed: 
Check DTC memory   Page 01
-12
   
      If specified value "Syst. OK" is obtained:  
     
Pa
ge 42 of 43 Readiness code11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.01.7 
         
        
        
     
        
        Page 43 of 43
- 
Click on   - button
     
Work step 13: Read readiness code 
     
- Read readiness code   Page 01
-79
 .
Pa
ge 43 of 43 Readiness code11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.01.7