15-71
- Disconnect connector from solenoid valve.
If specified value is not obtained:
Checking voltage supply - Connect multimeter at valve for resistance measurement.
Specified value: 10 ... 18
- Replace valve.
- Disconnect connector from solenoid valve.
If LED does not light: - Connect VAG 1527B voltage tester as follows:Harness connector
terminal
Measure to
1 Engine Ground (GND)
- Operate starter briefly.
LED must light.
- Perform following tests marked with dots:
Check fuse of solenoid valves for camshaft adjustment.
Pa
ge 71 of 99 Valve
gear, servicin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.GE05.15.1