ELECTRICAL
1
DESCRIPTION AND OPERATION ELECTRICAL EQUIPMENT
Description
The electrical system is Negative ground, and it is
most important to ensure correct polarity of electrical
connections at all times. Any incorrect connections
made when reconnecting cables may cause
irreparable damage to semi-conductor devices used in
generator and regulator. Incorrect polarity would also
seriously damage any transistorized equipment such
as a radio.
WARNING: During battery removal or
before carrying out any repairs or
maintenance to electrical components
always disconnect battery negative lead first. If
positive lead is disconnected with negative lead in
place, accidental contact of wrench to any
grounded metal part could cause a severe spark,
possibly resulting in personal injury. Upon
installation of battery positive lead should be
connected first.
GENERATOR
The generator is a three phase, field sensed unit. The
rotor and stator windings produce three phase
alternating current, AC, which is rectified to direct
current, DC. The electronic voltage regulator unit
controls generator output voltage by high frequency
switching of the rotor field circuit. Use only correct
replacement drive belt. Occasionally check that
engine and generator pulleys are accurately aligned.
It is essential that good electrical connections are
maintained at all times. Of particular importance are
those in the charging circuit (including those at
battery) which should be occasionally inspected to
see that they are clean and tight. In this way any
significant increase in circuit resistance can be
prevented.Do not disconnect battery cables while engine is
running or damage to semi-conductor devices may
occur. It is also inadvisable to break or make any
connections in the generator charging and control
circuits while engine is running.
The electronic voltage regulator employs micro-circuit
techniques resulting in improved performance under
difficult service conditions. The whole assembly is
encapsulated in silicone rubber and housed in an
aluminium heat sink, ensuring complete protection
against adverse effects of temperature, dust, and
moisture etc.
The regulating voltage is set during manufacture to
give required regulating voltage range of 14.2±0.2
volts, and no adjustment is necessary. The only
maintenance needed is occasional check on terminal
connections and wiping with a clean dry cloth.
The generator system provides for direct connection
of a charge (ignition) indicator warning lamp, and
eliminates the need for a field switching relay or
warning light control unit. In the event of bulb failure,
an 'exciter' voltage is supplied through a resistor,
wired in parallel to the bulbs, ensuring that generator
output is maintained. The lamp should be checked
regularly.
When using rapid charge equipment to re-charge
battery, the battery must be disconnected from the
vehicle.
ELECTRICAL
5
DESCRIPTION AND OPERATION REV: 05/99 ALARM SYSTEM OPERATION
Arming alarm
To arm the alarm, aim handset at vehicle and press
the RH button (Padlock symbol). Provided all doors
and or apertures are closed, the direction indicator
lamps will flash three times to confirm that the alarm is
armed. All security features previously described will
be active.
Once armed, the alarm will sound if a door or the
bonnet is opened, or if movement is detected inside
the vehicle.
Disarming alarm
Within range of the vehicle, briefly press the LH
(Plain) button on the handset; the direction indicator
lamps will flash once to indicate that the alarm has
been disarmed and the engine re-mobilised.
NOTE: In some territories, the interior
lamps will illuminate when the alarm is
disarmed.
If the direction indicators fail to flash when the
alarm is armed:
This indicates that a door or the bonnet is not fully
closed, in which case the alarm will be partially armed
and engine immobilised, but interior protection will not
be active.
Once the open door or bonnet is closed, the direction
indicators will flash three times and the alarm will fully
arm as described previously.
If the alarm sounds:
The vehicle horn and alarm sounder will operate
continuously for 30 seconds when the alarm is
triggered. The horn and alarm sounder can be
triggered up to three times.
To silence the alarm, press either handset button. If
the handset is inoperative, the alarm can only be
disarmed by entering the emergency key access
code, seeEngine immobilisation override.Anti-theft alarm indicator light
A RED indicator light on the instrument panel
indicates the status of the alarm system. When the
alarm is armed successfully, the light flashes rapidly.
After 10 seconds, the light adjusts to a slower
frequency and continues flashing as an anti-theft
deterrent.
If the light fails to illuminate during the rapid flash
phase, this indicates a 'mislock' (door or the bonnet
not fully closed or key in starter switch). If this occurs,
the indicator light will still flash at slower frequency as
an anti-theft deterrent.
The indicator light will illuminate continuously under
the following conditions:
1.Alarm system armed and immobilised with
ignition 'on' or driver's door open.
2.Engine immobilised with ignition 'on' or driver's
door open.
Interior protection
Interior protection is activated automatically when the
alarm system is armed; twin sensors inside the
vehicle monitor interior space and will activate the
alarm if an intrusion is detected.
However, if passengers or animals are to be left inside
the vehicle, or if a window or sunroof is to be left
open, the alarm must be armed with the interior
protection DISABLED as follows:
To disable interior protection:
1.Open the driver's door.
2.Use the handset to arm the alarm in normal way.
3.Close the driver's door (the direction indicator
lamps will flash three times and the anti-theft
indicator light commences flashing rapidly). The
alarm system is now armed with the interior
protection disabled.
NOTE: Interior protection will not operate
until 15 seconds after the alarm is set.
ELECTRICAL
9
DESCRIPTION AND OPERATION IMMOBILISATION AND ALARM SYSTEM CIRCUIT
DIAGRAM
1.Anti-theft alarm indicator light (LED)
2.Engine immobilisation warning light
3.Alarm system fuse - 15 amp
4.Alarm sounder relay
5.Under bonnet lighting fuse
6.Alarm sounder (without battery back-up)
7.Alarm system fuse - 5 amp (position 20)
8.Electronic control unit (ECU)
9.Bonnet switch
10.Alarm sounder protection fuse - 20 amp
(position 10)
11.Starter switch
12.Under bonnet ignition fuse
13.Driver's door switch
14.Vehicle horn switch
15.Vehicle horn
16.Passive coil
17.Starter switch relay
18.Front passenger door switch
19.Hazard warning light fuse - 15 amp (position 1)
20.Ultrasonic sensor
21.Interior lamp and horn fuse - 20 amp (position 3)
22.Alarm sounder (with battery back-up)
23.LH direction indicator lamps
24.RH direction indicator lamps
25.Interior lamp
26.Immobilisation spider
27.Rear side doors and rear door switches
28.Diagnostic connector
29.Diagnostic fuse - 7.5 amp
30.Starter solenoid
31.Fuel switch-off solenoid (injection pump)
32.Generator
33.AerialKey to cable colours
B-Black
G-Green
K-Pink
LG-Light Green
N-Brown
O-Orange
P-Purple
R-Red
S-Slate
U-Blue
W-White
Y-Yellow
The last letter of a colour code denotes the tracer
colour
ELECTRICAL
11
DESCRIPTION AND OPERATION IMMOBILISATION AND ALARM SYSTEM CIRCUIT
DIAGRAM - WITH DDS
1.Anti-theft alarm indicator light (LED)
2.Engine immobilisation warning light
3.Alarm system fuse - 15 amp
4.Alarm sounder relay
5.Under bonnet lighting fuse
6.Alarm sounder (without battery back-up)
7.Alarm system fuse - 5 amp (position 20)
8.Electronic control unit (ECU)
9.Bonnet switch
10.Alarm sounder protection fuse - 20 amp
(position 10)
11.Starter switch
12.Under bonnet ignition fuse
13.Driver's door switch
14.Vehicle horn switch
15.Vehicle horn
16.Passive coil
17.Starter switch relay
18.Front passenger door switch
19.Hazard warning light fuse - 15 amp (position 1)
20.Ultrasonic sensor
21.Interior lamp and horn fuse - 20 amp (position 3)
22.Alarm sounder (with battery back-up)
23.LH direction indicator lamps
24.RH direction indicator lamps
25.Interior lamp
26.Digital diesel shut-off valve (DDS)
27.Rear side doors and rear door switches
28.Diagnostic connector
29.Diagnostic fuse - 7.5 amp
30.Starter solenoid
31.Fuel shut-off solenoid (injection pump)
32.Generator
33.AerialKey to cable colours
B-Black
G-Green
K-Pink
LG-Light Green
N-Brown
O-Orange
P-Purple
R-Red
S-Slate
U-Blue
W-White
Y-Yellow
The last letter of a colour code denotes the tracer
colour
86ELECTRICAL
12
DESCRIPTION AND OPERATION VEHICLE ALARM SYSTEM BUILT-IN TEST
NOTE: The handset should be detached
from the key to allow perimetric testing of
the alarm system. The system will
automatically switch to volumetric testing if the
handset is in close proximity to the starter switch.
The built-in test procedure can be accessed providing
the following conditions exist:
Alarm disarmed.
Ignition 'off'.
Doors unlocked.
Bonnet closed.
With assistance, the test mode can be entered by
completing the following instructions within 5 seconds:
1.Open bonnet.
2.Turn starter switch 'on'.
3.Open driver's door (far enough to activate door
switch).
4.Turn starter switch 'off'.
5.Turn starter switch 'on'.
If the test mode has been correctly accessed, the
alarm sounder/horn will operate briefly and the
anti-theft alarm indicator and direction indicator lamps
will flash.
Perimetric tests
The anti-theft alarm indicator light and direction
indicator lamps will flash when:
1.Door switches are activated.
2.The bonnet is opened.
3.Key switches are activated.Volumetric tests
Press the LH (unlock) button or move the handset
close to the starter switch to disable perimetric testing
and enable volumetric testing. If movement is
detected within the vehicle by the ultrasonic sensor
the anti-theft alarm indicator and direction indicator
lamps will illuminate.
NOTE: Exit the anti-theft alarm built-in test
by turning the starter switch to the 'off'
position.
If the previously described conditions are not achieved
during the built-in test procedure, this would indicate a
fault in the alarm system. Before undertaking detailed
fault diagnosis procedures, first make visual checks of
components such as a faulty door switch or blown
alarm system fuse.
ELECTRICAL
1
REPAIR ELECTRICAL PRECAUTIONS
The following guidelines are intended to ensure the
safety of the operator whilst preventing damage to
electrical and electronic components fitted to the
vehicle.
Polarity
Never reverse connect the vehicle battery and always
observe the correct polarity when connecting test
equipment.
High voltage circuits
WARNING: Before commencing work on
an ignition system, all high tension
terminals, adaptors and diagnostic
equipment for testing should be inspected to
ensure that they are adequately insulated and
shielded to prevent accidental personal contacts
and minimize the risk of shock. Wearers of
surgically implanted pacemaker devices should
not be in close proximity to ignition circuits or
diagnostic equipment.
Whenever disconnecting live high tension circuits
always use insulated pliers and never allow the open
end of a high tension lead to come into contact with
other components particularly electronic control units.
Exercise caution when measuring the voltage on the
coil terminals while the engine is running, since, high
voltage spikes can occur on these terminals.
Connectors and harness
Always ensure that these items are dry and oil free
before disconnecting and connecting test equipment.
Never force connectors apart either by using tools or
by pulling on the wiring harness. Always ensure
locking tabs are disengaged before removal and note
orientation to enable correct reconnection. Ensure that
any protective covers and substances are replaced if
disturbed. Having confirmed a component to be faulty
switch-off the ignition and disconnect the battery.
Remove the component and support the disconnected
harness. When replacing the component keep oily
hands away from electrical connection areas and
push connectors home until any locking tabs fully
engage.Battery disconnecting
Before disconnecting the battery, switch off all
electrical equipment.
Battery charging
Recharge the battery out of the vehicle and keep the
top well ventilated. While being charged or
discharged, and for approximately 15 minutes
afterwards, batteries emit hydrogen gas which is
flammable. Always ensure any battery charging area
is well ventilated and that every precaution is taken to
avoid naked flames and sparks.
GENERAL PRECAUTIONS
Switch-off ignition prior to making any connection or
disconnection in the system as electrical surge
caused by disconnecting 'live' connections can
damage electronic components.
Ensure hands and work surfaces are clean and free of
grease, swarf, etc. as grease collects dirt which can
cause tracking or high-resistance contacts.
When handling printed circuit boards, treat them as
you would a disc - hold by the edges only.
Prior to commencing a test, and periodically during a
test, touch a good earth, for instance, a cigar lighter
socket, to discharge body static as some electronic
components are vulnerable to static electricity.