Page 4 of 47
13-4
 
  
-  Remove bolt -2- and screw in special tool 3369.
-  Screw in special tool 3369 into bore -5-.
-  Remove bolts -1- and -3-.
-  Remove bolts -4- and pull lock carrier out as far 
as it will go. 
-  Secure lock carrier with suitable M6 bolts in hole 
-6- (lock carrier) and hole -7- (fender panel). 
Pa
ge 4 of 47 En
gine, disassemblin
g and assemblin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.GE06.13.1 
     
        
        Page 11 of 47
13-11
 
  
14 - 
Generator 
Removing:
  - Disconnect battery Ground strap
 - Remove air duct hose to charge air 
cooler. 
 - Loosen ribbed belt and take belt off 
Generator  Page 13
-18
 . 
 - Remove viscous fan and put into radiator 
cowl. 
  - Remove electrical wiring from Generator.
 - Loosen connections for Generator from 
top and bottom and remove Generator. 
Installing:
 - To facilitate attachment of Generator 
slightly drive back thread bushing for 
securing bolt at bracket. 
Pa
ge 11 of 47 En
gine, disassemblin
g and assemblin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.GE06.13.1 
     
        
        Page 15 of 47
13-15
 
  
2 - 
Air conditioner compressor 
Do not loosen or disconnect refrigerant 
hoses or lines. After removing compressor from 
mountings, secure to chassis side member 
with wire or similar. Do not leave 
compressor suspended on refrigerant 
hoses. 
3 - 
Dowel sleeve Check sleeve is correctly seated in bracket
4 - 
33 Nm 
5 - 
Bracket For A/C compressor
6 - 
Tensioner For ribbed beltRemoving and installing ribbed belt   
Page 13
-18
 
Pa
ge 15 of 47 En
gine, disassemblin
g and assemblin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.GE06.13.1 
     
        
        Page 18 of 47
13-18
      
Ribbed belt, removing and installing
 
     
Note:  
     Mark the direction of rotation with chalk or felt 
pen before removing the ribbed belt. If the belt 
rotates in the wrong direction when it is refitted, 
belt breakage may result. Ensure that the belt is 
properly seated on the pulleys when installing. 
     
Removing  
    
-  Remove sound insulation -arrows-.
    
-  Loosen bolts securing ribbed belt tensioning roller for A/C compressor -
arrows-. 
Pa
ge 18 of 47 En
gine, disassemblin
g and assemblin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.GE06.13.1 
     
        
        Page 19 of 47
13-19
 
    
Note:   -  Turn tensioner in direction of arrow to loosen ribbed belt.
-  Remove ribbed belt from Generator and release tensioner.
    
When the lock carrier is in the service position, the ribbed belt tensioner 
can be secured to prevent it from turning by inserting a suitable pin or 
Allen key -arrow- into the holes. 
Pa
ge 19 of 47 En
gine, disassemblin
g and assemblin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.GE06.13.1 
     
        
        Page 21 of 47
13-21
      
Viscous fan, removing and installing
 
     
Removing  
     
Lock carrier must be in service position   
Page 13
-1 . 
    
-  To loosen ribbed belt, turn tensioner in direction of arrow.
-  Remove ribbed belt from Generator pulley.
    
-  Secure pulley for viscous fan with pin punch -1- and remove using 
Allen key -2-. 
-  Remove viscous fan. 
Pa
ge 21 of 47 En
gine, disassemblin
g and assemblin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.GE06.13.1 
     
        
        Page 25 of 47
13-25
 
    
-  Secure pulley for viscous fan with pin punch -1- and remove using 
Allen key -2-. 
-  Remove viscous fan from mounting.
    
-  Remove intake pipe support -arrows-.
Pa
ge 25 of 47 En
gine, disassemblin
g and assemblin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.GE06.13.1 
     
        
        Page 30 of 47
13-30
 
    
-  To loosen ribbed belt, turn tensioner in direction of arrow.
-  Remove ribbed belt from Generator pulley.
    
-  Secure pulley for viscous fan with pin punch -1- and remove using 
Allen key -2-. 
-  Remove viscous fan from mounting and put in front of radiator cowl.
-  Remove wiring from rear of Generator.
-  Loosen connections for Generator from top and bottom and remove 
Generator. 
Pa
ge 30 of 47 En
gine, disassemblin
g and assemblin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.GE06.13.1