1994 JAGUAR XJ6 sensor

[x] Cancel search: sensor

Page 144 of 327

JAGUAR XJ6 1994 2.G Electrical Diagnostic Manual Electrical 
FAULT CODE 45 
Front  Left  Impact Sensor Incorrectly  Mounted to  Vehicle 
Normal Operation 
The  DM monitors  the resistance  value between pins 21 and 3. If a resistance  of greater  th

Page 145 of 327

JAGUAR XJ6 1994 2.G Electrical Diagnostic Manual Electrical schematic - fault Code 45 
0 
0 
0 
r 
I 
588 
1. Instrument  Panel  Fuse 6. Passenger-side Air  Bag 
2. Engine  Compartment  Fuse 7. RH Impact Sensor 3. Safing  Sensor 8. LH Impact Sensor

Page 147 of 327

JAGUAR XJ6 1994 2.G Electrical Diagnostic Manual Electrical schematic - Fault Code 51 
0 
%- 
RP 
II I 
I 
1. Instrument  Panel Fuse 6. Passenger-side Air Bag 
2. Engine  Compartment  Fuse 7. RH Impact Sensor 3. Safing Sensor 8. LH Impact  Sensor 
4

Page 148 of 327

JAGUAR XJ6 1994 2.G Electrical Diagnostic Manual Electrical rl 
FAULT CODE 52 
Back-up Power  Supply - Voltage  Boost Fault 
Normal Operation 
The  DM contains a capacitor and a voltage boost  circuit to provide a back-up  power  supply. 
The  volta

Page 149 of 327

JAGUAR XJ6 1994 2.G Electrical Diagnostic Manual Electrical schematic - Fault Code 52 
0 
0 
0 
8 
r 
1U 
3 
PO3 1 
1. Instrument  Panel  Fuse 6. Passenger-side Air  Bag 
2. Engine  Compartment  Fuse 7. RH Impact Sensor 
3. Safing  Sensor 8. LH Impa

Page 150 of 327

JAGUAR XJ6 1994 2.G Electrical Diagnostic Manual rl Electrical 
FAULT CODE 53 
Front Impact  Sensor Circuits  Resistance  to Ground or Internal  Diagnostic  Monitor Failure 
Normal Operation 
The  DM measures  the voltage  on pins 2,6,17 and  18. If

Page 151 of 327

JAGUAR XJ6 1994 2.G Electrical Diagnostic Manual Electrical rl 
Electrical schematic - Fault Code 53 
0 
10 
T 
w? 
P21 
m 
‘T 
i OP I 
J86-1698 
1. Instrument  Panel  Fuse 6. Passenger-side Air  Bag 
7. RH Impact Sensor 2. Engine  Compartment  Fu

Page 152 of 327

JAGUAR XJ6 1994 2.G Electrical Diagnostic Manual Electrical 
RAPID CONTINUOUS  MIL LAMP  FLASHING 
Normal  Operation 
The front  impact  sensors  each have three connections  to the DM: supply,  supply monitor  and ground monitor. If the DM detects