TECHNICAL DATA TD
U. HEATER AND AIR CONDITIONER SYSTEMS
Item Specifications
Refrigerant amount
g (04
Refrigerant pressure kPa (kg/cm2, psi) 750-800 (26.5-28.2)
High: 1,177-1,619 (12.0-16.5, 171-235)
Low: 147-294 (1.5-3.0, 21-43)
Compressor
Magnetic clutch
Condenser fan
Recerver/Drier Capacity cc (cu in)
Compressor oil amount cc (cu in)
Electrical load w
Electrical load w
Capacity cc (cu in) 115 (7.0)
loo---120 (6.1-7.3)
31
77
330 (20.1)
STANDARD BOLT AND NUT TIGHTENING TORQUE
Diameter Pitch 4T 6T 8T
mm (in) mm (in) N-m m-kg ft-lb N.m m-kg ft-lb N.m m-kg ft-lb
6 (0.236) 1 (0.039) 4.2-6.2 0.43-0.63 3.1-4.6 6.9-9.8 0.7-1.0 5.0-7.2 7.8-11.8 0.8-1.2 5.8-8.8
8 (0.315) 1.25 (0.049) 9.8-14.7 1.0-1.5
7.2-10.8 16-23 1.6-2.3 12-17 18-26 1.8-2.7 13-20
10 (0.394) 1.25 (0.049) 20-28 2.0-2.9
14-21 31-46 3.2-4.7 23-34 36-54 3.7-5.5 27-40
12 (0.472) 1.5 (0.059) 34-50 3.5-5.1 25-37 55-80 5.6-8.2
41-59 63-93 6.4-9.5 46-69
14 (0,551) 1.5 (0.059)
- - - 75-103 7.7-10.5 56-76 102-137
lo-14 75-101
1 16 (0.630) 1 1.5 iO.059j 1 - 1 - - 116-157 12-16 85-116 156-211 16-22 115-156
1 18 ;0.709j Il.5 iO.O59 1 - 1 -
167
1 20 i0.787; Il.5 iO.059i 1 - 1 - 1 - 12:
31 _..
22 (0.866) 1 1.5 io.059j 1 - 1 - 1 - 1314-423 __ ._ ,--. -._,
1 I
24 (0.945) 1 1.5
(0.059) 1 -
- 1475-546 41-56 (298-4031536-7261 55-74 1396-536 -2251 17-23 123-166 221-299 23-31 163-221
-3141 24-32 171-231 308-417 31-43 227-307
37-43 331-312 417-564 43-58 307-416
TD-21
Z-Gl-8 Reading Wiring Diagrams
Svmbols I
Symbol Meaning Symbol Meaning
Battery (I, Generates electricity through Resistance l A resistor with a constant value
chemical reaction l Mainly used to protect electrical
l Supplies direct current to circuits components in circuits by maintaining
rated voltage
l Reading resistance values
Ground (1)
l Connecting point to vehicle body or No.1 Cobr band
-A- other ground wire where current flows -No.2 Cobr band
from positive to negative terminal of -No.3 Cobr band
battery No.4 Cobr band
1
l Ground (1) indicates a ground point to Flnt color. Rerkrancs
body through wire harness
Ground (2) l Gound (2) indicates point where
component is grounded directly to body
Remark
oCurrent wilt not flow through a circuit if
ground is faulty
Fuse (1)
(box)
Fuse (2)
l Melts when current flow exceeds that
specified for circuit, stopping current
flow
Precautions
o Do not replace with fuses exceeding
specified capacity
.
(Cartridge)
vlain fuse/Fusible
Transistor (1)
l Electrical switching component
a Turns on when voltage is applied to Motor
0 Converts electrical energy into
mechanical energy
Transistor (2)
coiibmr (Cl
l Reading code l Pulls in and expels gases and liquids
Lamp
Number of terminals O:Low- frequency NPN
l Emits light and generates heat when
Cigarette lighter
current flows through filament a Electrical coil that generates heat