1832-2. Charging
2
Plug-in hybrid system
Prius Plug-in Hybrid_OM_OM47E75E_(EE)
The error warning indicator on the CCID (Charging Circuit Interrupting
Device) flashes.
Electrical leakage detection
function or self- diagnostic
function operates and power
is cut off
When the voltage is insufficient, the error
warning indicator may flash when there is
noise interference. Perform a reset and con-
nect to a proper power source. (P. 120)
If charging does not start, immediately stop
charging and contact any authorized Toyota
retailer or Toyota authorized repairer, or any
reliable repairer.
Charging indicator does not illuminate, even though charging connector
is connected.
The plug is not properly con-
nected to the socketCheck whether the plug is properly con-
nected to the socket.
Charging connector is not
securely connected to
charging inlet
Check the connection status of the charging
connector.
• When connecting the charging connec-
tor, insert the charging connector
securely.
• After connecting the charging connector,
check that the charging indicator is turned
on.
If the charging indicator does not illuminate,
even though the charging connector is
securely connected, there may be a mal-
function in the system. Immediately stop
charging and contact any authorized Toyota
retailer or Toyota authorized repairer, or any
reliable repairer.
Hybrid battery (traction bat-
tery) is already fully chargedWhen the hybrid battery (traction battery) is
fully charged, charging is not performed.
The charger does not oper-
atePlease contact the facility manager when
there is a problem with charger.
Likely causeCorrection procedure