Page 4 of 88 Report No. : 60404490 001
TR F No. IEC62368_1 C
Summary of testing:
Tests performed (name of test and test clause):
All applicable tests as described in the test cases
and measurement sections were performed.
See test case and appended table for details.
This CB standard update test report is based on
CB test report No. 50040906 001, 50040906 002
and 500 40906 003 with the certificate No.
JPTUV - 071623 , JPTUV - 071623 - M 1 and
JPTUV - 071623 - M2 .
No technical changes in between as declared by
the manufacturer except for:
- Check and update certificate validity of critical
components and,
- Additional t ests and evaluation per the new
standard edition requirement. Testing location:
TÜ V Rheinland Korea Ltd.
Young City, N - Tower, 25, Mullae - ro 28 - gil,
Yeongdeungpo - gu, Seoul #07298 Korea, Rep . of
Additional test and evaluation:
- Cl.5.2 Classification of el ectrical energy sources
- Cl. 6.2.2 Electrical Power Source (PS)
measurements for classification
- Annex B.2.5 Input test
- Annex B.3, B.4 Abnormal operating and fault
condition tests
- Annex E Test conditions for equipment containing
audio amplifiers
- An nex T.8 Stress relief test
Summary of compliance with National Differences (List of countries addressed):
- EU Group Differences
The product fulfils the requirements of EN 62368 - 1:2014/A11:2017 and EN IEC 62368 -
1:2020+A11:2020 .
Page 6 of 88 Report No. : 60404490 001
TR F No. IEC62368_1 C
T est item particulars :
CAR AUDIO
Product group ................................ ..................... : end product built - in component
Classification of use by ................................ ....... : Ordinary person Children likely present
Instructed person
Skilled person
Supply c onnection ................................ ............... : AC mains DC mains
not mains connected :
ES1 ES2 ES3
Supply t olerance ................................ ................. : +10%/ - 10%
+20%/ - 15%
+ %/ - %
None
Supply c onnection – t ype ................................ .. : pluggable equipment type A -
non - detachable supply cord
appliance coupler
direct plug - in
pluggable equipment type B -
non - detachable supply cord
appliance coupler
permanent connection
mating connector other: PS3,ES1 (EV battery)
Considered current rating of protective device
................................ ................................ ............ : A;
Location: building equipment
N/A
Equipment mobility ................................ .......... : movable hand - held transportable
direct plug - in stationary for building - in
wall /c eiling - mounted SRME/rack - mounted
other:
Overvoltage c ategory (OVC) ........................... : OVC I OVC II OVC III
OVC IV other: EV battery
Class of equipment ................................ .......... : Class I Class II Class III
Not classif ied
Special installation location ........................... : N/A restricted access area
outdoor location
Pollution degree (PD) ................................ ...... :
PD 1 PD 2 PD 3
Manufacturer’s specified T
ma ........................... :
70 °C Outdoor: minimum °C
IP protection class ................................ ........... :
IPX0 IP___
Power s ystems ................................ ................. : TN TT IT - V
L - L
not AC mains
Altitude during operation (m) ......................... :
2000 m or less 5000 m
Altitude of test laboratory (m) ........................ :
2000 m or less m
Mass of equipment (kg) ................................ ... : 1. 80 kg
Page 9 of 88 Report No. : 60404490 001
TR F No. IEC62368_1 C
General product information and other remarks:
This product(CAR AUDIO) is a building - in type as component which has Bluetooth, Radio and DAB
functions.
It is Class III equipment supplied by a 12 V EV b attery.
It is intended to be built in a vehicle by an instructed person or skilled person as service person and user’s
manual shall be provided in the end equipment.
The Model L 64SK 2 is basic model and the model MIB2GP is identical to the basic model excep t for model
designation . It does not affect to safety factor.
The maximum ambient temperature permitted by the manufacturer (Tma): 70 o
C
This report is for standard up - date from IEC 60065:2014 to IEC 62368 - 1:2018 by earlier test report No.
50040906 001, 50 040906 002 and 50040906 003 with the certificate No. JPTUV - 071623 ,
JPTUV - 071623 - M1 and JPTUV - 071623 - M2.
The samples submitted for evaluation are representative of the final product and have the same quality in
items of safety aspect from each factory.
Whe n installing, all the requirements of IEC 62368 - 1 must be fulfilled.
Page 15 of 88 Report No. : 60404490 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
5.2.2 .2 Steady - state voltage and current limits .................... : (See appended table 5.2) P
5.2.2.3 Capacitance limits ................................ ..................... : N/A
5.2.2.4 Single pulse limits ................................ ..................... : No such single pulse with the
e quipment N/A
5.2.2.5 Limits for repetitive pulses ................................ ........ : No such repetitive pulses with
the e quipment N/A
5.2.2.6 Ringing signals No Ringing signals N/A
5.2.2.7 Audio signals P
5.3 Protection against electrical energy sources
N/A
5.3.1 General Requirements for accessible parts to
ordinary, instructed and skilled persons Only ES1 N/A
5.3. 1 a) Accessible ES1/ES2 derived from ES2/ES3 circuits N/A
5.3.1 b) Skilled persons not unintentional contact ES3 bare
conductors N/A
5.3.2.1 Accessibility to electrical energy sources and
safeguards N/A
Accessibility to outdoor equipment bare parts N/A
5.3.2.2 Contact requirements N/A
Test with test probe from Annex V -
5.3.2.2 a) Air gap – electric strength test potential (V) ............. : N/A
5.3.2.2 b) Air gap – distance (mm) ................................ ........... : N/A
5.3.2.3 Compliance N/A
5.3.2.4 Terminals for connecting strippe d wire N/A
5.4 Insulation materials and requirements
N/A
5.4.1.2 Properties of insulating material N/A
5.4.1.3 Material is non - hygroscopic N/A
5.4.1.4 Maximum operating temperature for insulating
materials ................................ ................................ .... : N/A
5.4.1.5 Pollution degrees ................................ ...................... : N/A
5.4.1.5.2 Test for pollution degree 1 environment and for an
insulating compound N/A
5.4.1.5.3 Thermal cycling test N/A
5.4.1.6 Insulation in transformers with varying dimensions N/A
5.4.1.7 Insulation in circuits generating starting pulses N/A
5. 4.1.8 Determination of working voltage ............................. : N/A
Page 27 of 88 Report No. : 60404490 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
30 s integrated exposure level (MEL30) .................. : N/A
Warning fo r MEL ≥ 100 dB(A) ................................ .. : N/A
10.6.4 Measurement methods N/A
10.6.5 Protection of persons N/A
Instructional safeguards ................................ ........ : N/A
10.6.6 Requirements for listening devices (headphones,
earphones, etc.) N/A
10.6.6.1 Corded listening devices with analogue in put N/A
Listening device input voltage (mV) ....................... : N/A
10.6.6.2 Corded listening devices with digital input N/A
Max. acoustic output L
Aeq,T , dB(A) ............................ :
N/A
10.6.6.3 Cordless listening devices N/A
Max. acoustic output L
Aeq,T , dB(A) ............................ :
N/A
B NORMAL OP ERATING CONDITION TESTS, ABNORMAL OPERATING
CONDITION TESTS AND SINGLE FAULT CONDITION TESTS P
B.1 General
P
B.1.5 Temperature measurement conditions (See appended table B.1.5) P
B.2 Normal operating conditions
P
B.2.1 General requirements ................................ ............ : (See Test Item Particulars and
appended test tables) P
Audio Amplifiers and equipment with audio
amplifiers ................................ ............................... : Complied with Annex E P
B.2.3 Supply voltage and tolerances EV battery used N/A
B.2.5 Input test ................................ ................................ : (See appended table B.2.5) P
B.3 Simulated abnormal operating conditions
P
B.3.1 General P
B.3.2 Covering of ventilation openings P
Instructional safeguard ................................ .......... : Not used on a soft support N/A
B.3.3 DC mains polarity test The connection is not
accessible to an ordinary
person N/A
B.3.4 Setting of voltag e selector No voltage selector N/A
B.3.5 Maximum load at output terminals P
B.3.6 Reverse battery polarity Battery is not provided N/A
Page 28 of 88 Report No. : 60404490 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
B.3.7 Audio amplifier abnormal operating conditions P
B.3.8 Safeguards functional during and after abnormal
operati ng conditions ................................ .............. : (See appended table B.3) P
B.4 Simulated single fault conditions
P
B.4.1 General P
B.4.2 Temperature controlling device N/A
B.4.3 Blocked motor test (See appended table B. 4 ) N/A
B.4.4 Functional insulation P
B.4.4.1 Sh ort circuit of clearances for functional insulation P
B.4.4.2 Short circuit of creepage distances for functional
insulation P
B.4.4.3 Short circuit of functional insulation on coated
printed boards N/A
B.4.5 Short - circuit and interruption of electrod es in tubes
and semiconductors P
B.4.6 Short circuit or disconnection of passive
components P
B.4.7 Continuous operation of components N/A
B.4.8 Compliance during and after single fault conditions
................................ ................................ ............... : (See appended table B.4) P
B.4.9 Battery charging and discharging under single fault
conditions Battery is not provided N/A
C UV RADIATION
N/A
C.1 Protection of materials in equipment from UV radiation
N/A
C.1.2 Requirements N/A
C.1.3 Test method N/A
C.2 UV light conditioning test
N/A
C.2.1 Test apparatus ................................ ....................... : N/A
C.2.2 Mounting of test samples N/A
C.2.3 Carbon - arc light - exposure test N/A
C.2.4 Xenon - arc light - exposure test N/A
D TEST GENERATORS
N/A
D.1 Impulse test generators
N/A
D.2 Antenna interface test generator
N/A
D.3 Electronic pul se generator
N/A
Page 29 of 88 Report No. : 60404490 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
E TEST CONDITIONS FOR EQUIPMENT CONTAINING AUDIO AMPLIFIERS
P
E.1 Electrical energy source classification for audio signals
P
Maximum non - clipped output power (W) .............. : 18. 66 W
Rated load impedance (Ω) ................................ ... : 4 Ω
Open - circuit output vo ltage (V) .............................. : 8. 6 4 V
Instructional safeguard ................................ .......... : ES1
E.2 Audio amplifier normal operating conditions
P
Audio signal source type ................................ ....... : 1 k H z sine wave
Audio output power (W) ................................ ......... : 1. 7 0 W
Audio output voltage (V) ................................ ........ : 2. 6 1 V
Rated load impedance (Ω) ................................ ... : 4 Ω
Requirements for temperature measurement P
E.3 Audio amplifier abnormal operating conditions P
F EQUIPMENT MARKINGS, INSTRUCTIONS, AND INSTRUCTIONAL
SAFEGUARDS P
F.1 General
P
Language ................................ .............................. : English
F.2 Letter symbols and graphical symbols
P
F.2.1 Letter symbols according to IEC60027 - 1 P
F.2.2 Graphic symbols according to IEC, ISO or
manufacturer specific P
F.3 Equipment markings
P
F.3.1 Equipment marking locations Equipment marking is located
on the exterior surface and is
easily vis ible P
F.3.2 Equipment identification markings P
F.3.2.1 Manufacturer identification ................................ ... : See copy of marking plate P
F.3.2.2 Model identification ................................ ............... : See copy of marking plate P
F.3.3 Equipment rating markings P
F.3.3.1 Equipment with direct connectio n to mains P
F.3.3.2 Equipment without direct connection to mains N/A
F.3.3.3 Nature of the supply voltage ................................ .. : IEC 60417 - 5031 P
F.3.3.4 Rated voltage ................................ ........................ : See copy of marking plate P
F.3.3.5 Rated frequency ................................ .................... : N/A
Page 30 of 88 Report No. : 60404490 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
F.3.3.6 Rated current or rated power ................................ : See copy of marking plate P
F.3.3.7 Equipment with multiple supply connections N/A
F.3.4 Voltage setting device N/A
F.3.5 Terminals and operating devices N/A
F.3.5.1 Mains appliance outlet and socket - outlet markings
................................ ................................ ............... : No such component N/A
F.3.5.2 Switch position identification marking .................... : No such component N/A
F.3.5.3 Replacement fuse identification and rating
markings ................................ ................................ : No replaceable fuse N/A
Instructional safeguards for neutral fuse ............... : No such component N/A
F.3.5.4 Replacement battery identifi cation marking .......... : No replaceable battery N/A
F.3.5.5 Neutral conductor terminal N/A
F.3.5.6 Terminal marking location N/A
F.3.6 Equipment markings related to equipment
classification N/A
F.3.6.1 Class I equipment N/A
F.3.6.1.1 Protective earthing c onductor terminal .................. : N/A
F.3.6.1.2 Protective bonding conductor terminals ............... : N/A
F.3.6.2 Equipment class marking ................................ ...... : N/A
F.3.6.3 Functional earthing terminal marking .................... : N/A
F.3.7 Equipment IP rating marking ................................ . : N/A
F.3.8 External power supply output ma rking .................. : N/A
F.3.9 Durability, legibility and permanence of marking P
F.3.10 Test for permanence of markings P
F.4 Instructions
N/A
a) Information prior to installation and initial use It shall be evaluated in the
end - equipment N/A
b) Equipment fo r use in locations where children not
likely to be present N/A
c) Instructions for installation and interconnection N/A
d) Equipment intended for use only in restricted
access area N/A
e) Equipment intended to be fastened in place N/A
f) Instr uctions for audio equipment terminals N/A
g) Protective earthing used as a safeguard N/A