Page 109 of 464
1093. Instrument cluster
3
Instrument cluster
MIRAI_OM_USA_OM62023U
These images are examples only, and may vary slightly from actual
conditions.
When the vehicle is powered by the fuel cell
stack and traction battery
When the vehicle is charging the traction bat-
tery
When there is no energy flow
Traction battery status
LowFull
Page 110 of 464

1103. Instrument cluster
MIRAI_OM_USA_OM62023U■
Fuel cell system indicator and ECO Score
The output power of the fuel cell system, regeneration level display,
and the ECO driving is scored and displayed.
Charge area
Shows that energy is being
recovered via the regenera-
tive brake.
Eco area
Shows that the vehicle is
being driven in an Eco-
friendly manner.
Power area
Shows that an Eco-friendly dr iving range is being exceeded.
ECO Score
Displays the driving conditions in 5 stages, which are separated
in the 3 patterns of ECO Start, ECO Cruise and ECO Stop. Also,
each time the vehicle is stopped, that number is displayed. (The
number for each take off is reset and not counted)
● By maintaining the indicator display in the ECO area or Charge
area, Eco-friendly driving is possible.
● Charge area indicates regeneration
* status. Regenerated energy
will be used to charge t he traction battery.
*: When used in this manual, “regeneration” refers to the conversion of
energy created by the movement of the vehicle into electrical energy.
Page 111 of 464
1113. Instrument cluster
3
Instrument cluster
MIRAI_OM_USA_OM62023U■
Fuel consumption record
To toggle through the items, press on the meter control switches
( → P. 108) to select the tab and then press either or .
1-minute fuel consumption
Average fuel consumption in the
past 15 minutes, displayed in
1-minute intervals
5-minute fuel consumption
Average fuel consumption in the
past 30 minutes, displayed in
5-minute intervals
Monthly fuel consumption
Average fuel consumption over
the past 6 months
The scale of the vertical axis can
be changed by pressing or
of the meter control switches.
Press on the meter control
switches ( →P. 108) to return.
Page 112 of 464
1123. Instrument cluster
MIRAI_OM_USA_OM62023U■
Drive monitor
Driving time
Displays the amount of time
since starting
*1 the fuel cell
system or resetting
*2.
Average vehicle speed
Displays the average vehicle
speed since starting
*1 the
fuel cell system or reset-
ting
*2.
Average fuel consumption
Displays the average fuel consumption since starting
*1 the fuel
cell system or resetting
*2.
*1: When the odometer, traveled distance since starting, or blank is dis-
played in the odometer and trip meter of the main display
*2: When trip meter A or trip meter B is displayed in the odometer andtrip meter of the main display
Page 113 of 464
1133. Instrument cluster
3
Instrument cluster
MIRAI_OM_USA_OM62023U■
ECO diary
To toggle through the items, press on the meter control switches
( → P. 108) to select the tab and then press either or .
Daily history
Press either or of the
meter control switches to scroll
through the days displayed.
Monthly history
Press either or of the
meter control switches to scroll
through the months displayed.
Press on the meter control switches ( →P. 108) to return.
■Power meter
Displays the output power and
regeneration level of the fuel cell
system.
Page 114 of 464
1143. Instrument cluster
MIRAI_OM_USA_OM62023U
■Suspension of the settings display
In the following situations, the settings display using the meter control
switches will be suspended.
●When a warning message appears on the multi-information display
● When the vehicle begins to move
■ When the 12-volt battery terminal is disconnected and reconnected
The following data is reset when the 12-volt battery terminal is disconnected
and reconnected.
●1-minute fuel consumption
● 5-minute fuel consumption
● Driving time
● Average vehicle speed
● Average fuel consumption
■ Liquid crystal display
→P. 106
NOTICE
■During setting up the display
To prevent 12-volt battery discharge, ensure that the fuel cell system is
operating while setting up the display features.
Page 118 of 464

1184-1. Key information
MIRAI_OM_USA_OM62023U■
Electronic key battery depletion
●The standard battery life is 1 to 2 years.
● If the battery becomes low, an alarm will sound in the cabin when the fuel
cell system stops. ( →P. 376)
● As the electronic key always receives radio waves, the battery will become
depleted even if the electronic key is not used. The following symptoms indi-
cate that the electronic key battery may be depleted. Replace the battery
when necessary. ( →P. 353)
• The smart key system or the wireless remote control does not operate.
• The detection area becomes smaller.
• The LED indicator on the key surface does not turn on.
● To avoid serious deterioration, do not leave the electronic key within 3 ft. (1
m) of the following electrical appl iances that produce a magnetic field:
•TVs
• Personal computers
• Cellular phones, cordless phones and battery chargers
• Recharging cellular phones or cordless phones
• Table lamps
• Induction cookers
■ Replacing the battery
→P. 353
■ Confirmation of the registered key number
The number of keys already registered to the vehicle can be confirmed. Ask
your Toyota dealer for details.
■ If a wrong key is used
The key cylinder rotates freely to isolate inside mechanism.
Page 131 of 464
1314-2. Opening, closing and locking the doors
4
Operation of each component
MIRAI_OM_USA_OM62023U
Smart key system
●Locks and unlocks the doors ( →P. 120)
● Opens the trunk ( →P. 126)
● Starts and stops the fuel cell system ( →P. 172)
■Antenna location
The following operations can be performed simply by carrying
the electronic key on your person, for example in your pocket.
The driver should always carry the electronic key.
Antennas outside the cabin
Antennas inside the cabin
Antenna inside the trunk
Antenna outside the trunk