3-1 Preparation Items
Preparation Items Specification Purpose
PPE (personal protective equipment): Up to 1,000V For protection from high voltage
electrical shock.
Insulated gloves
Insulated shoes
–
Safety shield
– To protect eyes when around high
voltage components and wiring.
Safety Glasses
Leather glovesMust be able to fasten tight around
the wrist (worn over insulated
gloves) . To protect insulated gloves.
Wrenches
Size:10mm To remove the 12-volt battery terminal bolt.
Solvent resistant protection gloves
Solvent resistant protectionshoes –To utilize in the event of a high voltage
battery electrolytic solution leak.
Absorbent pad The same pad used for internal combustion engine fluids can beused. To absorb any high voltage battery
electrolytic solution leakage.
Standard fire fightingequipment Standard fire fighting equipment.
Depending on type of fire (vehicle
or battery) use standard fire
fighting equipment (water or
extinguisher) . To extinguish a fire.
Insulated tape Insulating To cover any damaged harnesses to protect from and prevent electrical
shock. Tape should cover all bare or
damaged wire.
DG–17
3-4.3 Water Submersion
DANGER
Damage level of submerged vehicle may not be apparent. Handling a submerged
vehicle without appropriate Personal Protective Equipment (PPE) will result in serious
injury or death from electrical shock.
•The ignition switch of the submerged vehicle must be turned OFF first, if possible.
Then the vehicle must be completely out of the water and drained to avoid electrical shock.
•
Always wear appropriate Personal Protective Equipment (PPE) and remove/drain
water before removing the service plug when working on a vehicle after a fire or
submersion to avoid electrical shock.
•
If the vehicle is in the water, to avoid electrical shock NEVER touch the high-voltage
components, harnesses or service plug. PPE must always be worn when touching or
working on high-voltage components.
3-4.4 Vehicle Fire
• Always utilize full Personal Protective Equipment (PPE) and self-contained breathing apparatus during fire fighting operations. Smoke from a Q70 HYBRID vehicle fire is
similar to smoke from a conventional vehicle fire.
• In the case of extinguishing a fire with water, large amounts of water from a fire hydrant (if possible) must be used. DO NOT extinguish fire with a small amount of water.
In the event of a small fire, a Type ABC fire extinguisher may be used for an electrical fire
caused by wiring harnesses, electrical components, etc. or oil fire.
In case of vehicle fire, contact fire department immediately and extinguish the fire if possible. If you must
walk away from the vehicle, notify an appropriate responder or a rescue person of the fact that the vehicle is
a hybrid vehicle that contains a high voltage system and warn all others. DG–32