Preparation Items Specification Purpose
Solvent resistant protection gloves
Solvent resistant protection shoes – To utilize in the event of a high-
voltage battery electrolytic solutionleak.
Absorbent pad The same pad used for internal combustion engine fluids can beused.To absorb any high-voltage battery
electrolytic solution leakage.
Standard fire fighting equipment Standard fire fighting equipment.
Depending on type of fire
(vehicle or battery) use standard
fire fighting equipment (water or
extinguisher) .To extinguish a fire.
Insulated tape Insulating To cover any damaged harnesses to protect from and prevent
electrical shock. Tape should
cover all bare or damaged wire.
3-1.1 Personal Protective Equipment (PPE) Protective Wear Control
Perform an inspection of the Personal Protective Equipment (PPE) items before beginning work. Do not use
any damaged PPE items.
3-1.2 Daily Inspection
This inspection is performed before and after use. The worker who will be using the items should perform
the inspection and check for deterioration and damage. • Insulated rubber gloves should be inspected for scratches, holes and tears. (Visual check and airleakage test)
• Insulated safety boots should be inspected for holes, damage, nails, metal pieces, wear or other problems on the soles. (Visual check)
• Insulated rubber sheet should be inspected for tears. (Visual check)
3-1.3 Insulated Tools
When performing work at locations where high-voltage is applied (such as terminals) , use insulated tools
meeting 1,000V/300A specifications.
3-2 Indications the High-voltage System is ON
If the READY
indicator is ON, the high-voltage system is active.
Before disconnecting the 12-volt battery terminal, if necessary, lower the windows, unlock the doors, and
open the rear hatch as required. Once 12-volt battery is disconnected, power controls will not operate.
RAG–15