Page 19 of 98

INSTRUMENT AND CONTROL FUNCTIONS
3-4
234
5
6
7
8
9
TIPIndicator “ ” comes on when tripmeter
A is selected, and indicator “ ” comeson when tripmeter B is selected.
To reset a tripmeter, select it by push-
ing the “SLCT 2” button, and then push
the “RST” button for at least one sec-
ond.
ClockThe clock displays when the main
switch is pushed to “ON”.
To set the clock1. Push the “SLCT 1” button for atleast two seconds.
2. When the hour digits start flashing, push either select button to set the
hours.
3. Push the “RST” button, and the minute digits will start flashing.
4. Push either select button to set the minutes.
5. Push the “RST” button, and the second digits will start flashing.
6. Push either select button to set the second digits to zero.
7. Push the “RST” button for at least two seconds, and then release it to
start the clock.
TIP
When setting the clock, push the
“SLCT 1” button to increase the
digits or “SLCT 2” button to de-
crease the digits. Pushing and
holding either button will increase
or decrease the digits continuously
until the button is released.
If a button is not pushed within 30
seconds while setting the clock,
the clock will be set to the currentlydisplayed time. Changing from the basic mode to
the measurement mode
With the odometer selected, push the
“SLCT 1” button and “SLCT 2” button
together for at least two seconds to
change to the measurement mode.
Changing from the measurement
mode to the basic mode
TIPThe stopwatch must be stopped beforechanging to the basic mode.
1. Check that the stopwatch is not in operation. If the stopwatch is in op-
eration, stop it by pushing the
“SLCT 1” button and “SLCT 2” but-
ton together.
2. Push the “SLCT 1” button and “SLCT 2” button together for at
least two seconds to change to the
basic mode.
Measurement mode (for the stop-
watch)
When the measurement mode is se-
lected, the stopwatch is displayed and it
can be started manually or automatical-
ly.
1. Tripmeter B indicator “ ”
1
1DX-9-E2.book 4 ページ 2013年2月26日 火曜日 午後2時34分
Page 20 of 98

INSTRUMENT AND CONTROL FUNCTIONS
3-5
1
23
4
5
6
7
8
9
TIPStarting measurement consists of the
following two starts, either of which can
be selected.
Manual start
Starting measurement by the rider
himself operating the button. (A
long push on the “SLCT 2” button
will put measurement on standby.)
Auto start
Starting timer measurement auto-
matically on detection of the move-
ment of the machine. (A long push
on the “SLCT 1” button will putmeasurement on standby.)
Manual start
The manual start is the default setting
for the stopwatch. The stopwatch indi-
cator “ ” and the distance-compensa-
tion tripmeter indicator “ ” will start
flashing. 1. Push the “RST” button to start the
stopwatch.
2. Push the “SLCT 1” button and “SLCT 2” button together to stop
the stopwatch.
3. To resume stopwatch counting, push the “SLCT 1” button and
“SLCT 2” button together.
To reset the stopwatch to zero,
push the “RST” button for at least
two seconds.
TIPThe stopwatch will continue counting
when the vehicle is stopped. To stop
and/or resume counting, repeat steps 2and 3. Auto start
1. Push the “SLCT 1” button for at
least two seconds to set the auto
start.TIPWhen the stopwatch is set to auto start,
the stopwatch indicator “ ” and the
distance-compensation tripmeter indi-
cator “ ” will start flashing, and the dig-
its in the display will start scrolling fromleft to right.
2. When the vehicle starts moving, the stopwatch will start counting.
3. Push the “SLCT 1” button and “SLCT 2” button together to stop
the stopwatch.
4. To resume counting, push the “SLCT 1” button and “SLCT 2” but-
1DX-9-E2.book 5 ページ 2013年2月26日 火曜日 午後2時34分
Page 21 of 98

INSTRUMENT AND CONTROL FUNCTIONS
3-6
234
5
6
7
8
9
ton together again.
TIPThe stopwatch will continue counting
when the vehicle is stopped. To stop
and/or resume counting, repeat steps 3and 4.
Measurement mode (for calibrating
the distance-compensation tripme-
ter’s reading)
The distance-compensation tripmeter
is a feature intended to provide a more
accurate tripmeter reading for enduro
riding. Calibrating this meter in accor-
dance with the distances specified on
the enduro course map will help famil-
iarize the rider with the course. In addi-
tion, calibrating the meter may also be
necessary when using tire, wheel,
chain sprocket sizes, etc. other than
specified. For further information con-
cerning the use of this meter, please
consult your nearby Yamaha dealer.
Calibrate the distance-compensation
tripmeter as follows.
To increase the reading, push the
“SLCT 1” button. To decrease the read-
ing, push the “SLCT 2” button. Pushing and holding either button will increase
or decrease the reading continuously
until the button is released.
TIPCalibrating the reading of the dis-
tance-compensation tripmeter is possi-
ble regardless of the stopwatchoperation.
Resetting the distance-compensa-
tion tripmeter or the distance-com-
pensation tripmeter in combination
with the stopwatchTIPResetting can be made only to the dis-
tance-compensation tripmeter or to the
distance-compensation tripmeter incombination with the stopwatch.
Resetting the distance-compensationtripmeter1. Check that the stopwatch mea-
surement is in operation.
2. Reset the distance-compensation tripmeter to zero by pushing the
“RST” button for at least two sec-
onds. Resetting the distance-compensation
tripmeter in combination with the stop-watch1. Stop the stopwatch.
2. Reset the distance-compensation
tripmeter and the stopwatch to
zero by pushing the “RST” button
for at least two seconds.
1DX-9-E2.book 6 ページ 2013年2月26日 火曜日 午後2時34分