PETROL INJECTION
Fault finding – System operation17B
17B - 9V12 MR-372-J84-17B000$090.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
2. OPERATIONAL SAFETY
Warning lights illumination
The S3000 injection system manages the illumination of three warning lights and the issuing of warning messages
according to the severity of the faults detected, to inform the customer and to direct fault finding.
The injection computer manages the illumination of warning lights and warning messages displayed on the instrument
panel. These warning lights illuminate during the starting phase and in the event of an injection fault or engine
overheating.
The warning light illumination signals reach the instrument panel via the multiplex network.
Warning light illumination principle
During the starting phase (START button pressed) the OBD (On Board Diagnostic) warning light comes on for
approximately 3 seconds then goes out.
If there is an injection fault (severity 1), the INJECTION FAULT written message lights up followed by the SERVICE
warning light. It indicates a reduced level of operation and a limited safety level.
The driver should carry out repairs as soon as possible.
Components involved:
– motorised throttle valve,
– accelerator pedal potentiometer,
– inlet manifold pressure sensor,
–computer,
– actuator feed,
– computer feed.
If there is a serious injection fault (severity 2), the red engine symbol and the word STOP appear (display with
information display only), with the ENGINE OVERHEATING written message followed by the STOP warning light
and a buzzer. If this happens, the vehicle must be stopped immediately.
When a fault causing excessive pollution in the exhaust fumes is detected, the orange OBD warning light, an engine
symbol, will be lit:
–flashing in the event of a fault which might irreparably damaged the catalytic converter (destructive misfire). If this
happens you must stop the vehicle immediately,
–constantly in the case of non-compliance with the anti-pollution standards (pollutant misfire, catalytic converter
fault, oxygen sensor faults, inconsistency between the oxygen sensors and canister fault).
Mileage travelled with fault
This parameter serves to measure the distance travelled with one of the injection fault warning lights on: level 1 fault
warning light (amber), coolant temperature overheating warning light, or OBD warning light.
The counter can be reset to 0 using the diagnostic tool.
JSAA741.0
PETROL INJECTION
Fault finding – Fault summary table17B
17B - 17V12 MR-372-J84-17B000$270.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48PETROL INJECTION
Fault finding – Fault summary table
Tool
faultsHexadecimal
DTC codesDescriptionLevel 1 fault
warning lightNo warning
light onOBD warning
light
DF0010115Coolant temperature
sensor circuit1.DEF
DF0020110Air temperature sensor
circuit1.DEF
DF0040235Turbocharging pressure
sensor circuit1.DEF/2.DEF 1.DEF/2.DEF
DF0080225Pedal potentiometer
circuit gang 1CO.0/CC.1
1.DEF
DF0092120Pedal potentiometer
circuit gang 2CO.0/CC.1
DF0110641 Sensor feed voltage no. 1 1.DEF/2.DEF
DF0120651 Sensor feed voltage no. 2 1.DEF/2.DEF
DF0260201Cylinder 1 injector control
circuitCO/ CC.0
CC.1
DF0270202Cylinder 2 injector control
circuitCO/ CC.0
CC.1
DF0280203Cylinder 3 injector control
circuitCO/ CC.0
CC.1
DF0290204Cylinder 4 injector control
circuitCO/ CC.0
CC.1
DF0370633 Engine immobiliser 1.DEF
DF0380606 Computer 1.DEF
DF0460560 Battery voltage 1.DEF
DF0490530 Refrigerant sensor circuit 1.DEF
DF0540243Turbocharging solenoid
valve control circuitCO/ CC.0
CC.1
JSAA741.0
MR-372-J84-17B000$270.mif
PETROL INJECTION
Fault finding – Fault summary table17B
17B - 19V12 MR-372-J84-17B000$270.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
*AT: Automatic Transmission
*BVR: Sequential gearboxTool
faultsHexadecimal
DTC codesDescriptionLevel 1 fault
warning lightNo warning
light onOBD warning
light
DF0840685Actuator relay control
circuit1.DEF
DF0850627Fuel pump relay control
circuitCO/ CC.0
CC.1
DF0862600Coolant pump control
circuitCO/ CO.0
CC.1
DF0880325 Pinking sensor circuit 1.DEF
DF0890105Inlet manifold pressure
sensor circuit1.DEF
2.DEF
DF0910500 Vehicle speed signal 1.DEF
DF0920130Upstream oxygen
sensor circuitCO.0
CC.1
1.DEF
DF0930136Downstream oxygen
sensor circuitCO.0/CC.1
DF0950120Throttle potentiometer
circuit gang 1CO.0/CC.1
1.DEF
DF0960220Throttle potentiometer
circuit gang 2CO.1/CC.0
DF099C101TA* or BVR*
connection via the
multiplex network1.DEF
DF100C155Instrument panel
multiplex connection1.DEF
DF101C122Multiplex ESP
connection1.DEF
DF1050585Cruise control/speed
limiter on/off circuit1.DEF
DF1060575Cruise Control/Speed
Limiter function selector
on steering wheel1.DEF
DF108C115LPG/CNG computer
multiplex connection1.DEF
JSAA741.0
PETROL INJECTION
Fault finding – Interpretation of faults17B
17B-26V12 MR-372-J84-17B000$315.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
DF011
PRESENT
OR
STOREDSENSOR SUPPLY VOLTAGE NO. 1
1.DEF : voltage outside tolerances
2.DEF : internal electronic fault
NOTESPriority for dealing with a combination of faults:
Deal with the other faults first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after:
– the ignition is switched on.
– loss of dialogue between the inter-systems (ESP, CC/SL),
– power loss when accelerating.
Special note:
–level 1 fault warning light illuminated,
– Throttle valve defect mode types 1 and 2.
Check the cleanliness and condition of the throttle valve connections.
Check the cleanliness and condition of the pedal potentiometer connections.
Disconnect the battery and the injection computer.
Check the cleanliness and condition of the connections.
Repair if necessary.
Sensor feed No. 1 is reserved for the following components:
– motorised throttle valve,
– coolant temperature sensor,
– pedal potentiometer gang 1,
– upstream and downstream oxygen sensors,
– motorised throttle potentiometer gangs 1 and 2.
If, with sensors disconnected the voltage is still less than 4.9 V or greater than 5.1 V:
– check the insulation from earth of the + 5 V line of each of its sensors.
Use the "Universal bornier" to check the insulation and continuity of the following connections:
Computer, connector B, track G2 Track 2 of the throttle valve
Computer, connectorA, track G2 Track 3 of the pedal potentiometer gang 1
Repair if necessary.
If the fault is still present, there is a computer fault. Contact the Techline.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
S3000_V44_DF011/S3000_V48_DF011JSAA741.0
PETROL INJECTION
Fault finding – Interpretation of faults17B
17B-27V12 MR-372-J84-17B000$315.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
DF012
PRESENT
OR
STOREDSENSOR SUPPLY VOLTAGE No. 2
1.DEF : voltage outside tolerances
2.DEF : internal electronic fault
NOTESPriority for dealing with a combination of faults:
Deal with the other faults first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after:
– the ignition is switched on.
– loss of power when accelerating,
– loss of inter-systems (ESP, CC/SL).
Special note:
–level 1 fault warning light illuminated.
– throttle valve defect mode types 4 and 6.
Check the cleanliness and condition of the throttle valve connections.
Check the cleanliness and condition of the pedal potentiometer connections.
Disconnect the battery and the injection computer.
Check the cleanliness and condition of the connections.
Repair if necessary.
Sensor feed no. 2 is reserved for the following components:
– turbocharger pressure sensor,
– pedal potentiometer gang 2,
– coolant pressure sensor,
– Inlet manifold pressure sensor.
If, with the sensors disconnected, the voltage is still less than 4.9 V or greater than 5.1 V:
– check the insulation from earth of the + 5 V line of each of its sensors.
Using the Universal bornier, check the insulation and continuity on the following connection:
Computer, connectorA, track F2 Track 2 of the pedal potentiometer gang 2
Repair if necessary.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
S3000_V44_DF012/S3000_V48_DF012JSAA741.0