2014 INFINITI QX60 HYBRID First Responder´s

Page 17 of 44

INFINITI QX60 HYBRID 2014  First Responder´s 3. Emergency Response Steps
•Failure to properly shut down the high voltage electrical system before the
Emergency Response Procedures are performed will result in serious injury or death 
from elec

Page 18 of 44

INFINITI QX60 HYBRID 2014  First Responder´s 3-1 Preparation Items
Preparation Items Specification Purpose
PPE (personal protective equipment): 
Insulated gloves
Up to 1,000V For protection from high voltage electri- 
cal shock
Insulated shoes

Page 19 of 44

INFINITI QX60 HYBRID 2014  First Responder´s 3-1.3 Insulated Tools 
When performing work at locations where high voltage is applied (such as terminals) , use insulated tools 
meeting 1,000V/300A specifications. 
3-2 Vehicle Immobilization and St

Page 20 of 44

INFINITI QX60 HYBRID 2014  First Responder´s When arriving to an incident involving an INFINITI QX60 HYBRID, the vehicle should be approached with 
caution and inspected for the level of damage. In addition to overall vehicle condition (location

Page 21 of 44

INFINITI QX60 HYBRID 2014  First Responder´s •Failure to properly shut down the high voltage system before the Emergency
Response Procedures are performed will result in serious injury or death from 
electrical shock. To prevent serious injury

Page 22 of 44

INFINITI QX60 HYBRID 2014  First Responder´s Powering Down the High Voltage System 
The high voltage system can be shut down with any 1 of the following procedures:• Turn OFF the power switch and disconnect the 12V battery. Refer to
Primary Pr

Page 23 of 44

INFINITI QX60 HYBRID 2014  First Responder´s Primary Procedure 
NOTE:Before disconnecting the 12V battery terminal, if necessary, lower the windows, adjust the 
steering column, adjust the seats, unlock the doors, etc. Once 12V battery is discon

Page 24 of 44

INFINITI QX60 HYBRID 2014  First Responder´s 6. Remove traction motor inverter cover (1) . 
7. Disconnect negative (-) battery cable and cover it withinsulated tape.
8. Wait approximately ten (10) minutes for complete discharge of the high volta