Page 88 of 192
86
Bipper_en_Chap05_technologie_ed02-2014
Menu...Press... Sub-menu... Press... Select... Confirm
and exitEnables you to...
5 See radio ON
Display the name of the station.
Display the CD track
number.
OFF
6 Autoclose While moving ON
Activate/Deactivate the
automatic locking of the doors
above 12
mph (20 km/h)
OFF
7
Measurement unit
Distances Km
Select the distance display
unit.
Mi(les)
temperature °C
Select the temperature display
unit.
°F
Consumption km/l
Select the fuel consumption
display unit.
l/100 km
8
l
anguage
l
ist of
languages
available Select the display language.
9
Volume of
announcements
Increase Increase/Decrease the volume
of the signals and warnings
(the change is immediate when
the button is pressed).
Decrease
10
Button
volume Increase
Increase/Decrease the volume
for the buttons.
Decrease
Vehicle configuration
Page 118 of 192

11 6
Bipper_en_Chap06_securite_ed02-2014
TYRE UNDER-INFLATION DETECTION
System which automatically checks the
pressure of the tyres while driving.
t
he system monitors the pressures on the
four tyres, once the vehicle is moving.
It compares the information given by the
four wheel speed sensors with reference
values, which must be reinitialised every
time the tyre pressures are adjusted or a
wheel changed.
t
he system triggers an alert as soon as it
detects a drop in the inflation pressure of
one or more tyres.
t
he under-inflation detection system
does not replace the vigilance or the
responsibility of the driver.
t
his system does not avoid the need to
check the tyre pressures (including the
spare wheel) every month as well as before
a long journey.
Driving with under-inflated tyres impairs
road holding, extends braking distances and
causes premature tyre wear, particularly
under arduous condition (high loading, high
speed, long journey).
Driving with under-inflated tyres increases
fuel consumption.
t
he inflation pressures defined for
your vehicle can be found on the tyre
pressure label.
See the "Identification markings" section.
tyre pressures should be checked when the
tyres are "cold" (vehicle stopped for 1 hour
or after a journey of less than 6 miles
(10 km) at moderate speeds).
Otherwise (when hot), add 0.3 bar to the
pressures shown on the label.
Under-inflation alert
This is given by fixed
illumination of this warning lamp,
accompanied the display of a
message,depending on equipment.
F
Reduce speed immediately
, avoid
excessive steering movements and
sudden braking
F
Stop the vehicle as soon as it is safe to
do so.
t
he loss of pressure detected does
not always cause visible bulging of the
tyre. Do not satisfy yourself with just a visual
check.
F
In the event of a puncture, use the
temporary puncture repair kit or the spare
wheel (depending on equipment),
or
F
if you have a compressor
, such as the
one in the temporary puncture repair kit,
check the pressures of the four tyres
when cold,
or
F
if it is not possible to make this check
immediately, drive carefully at reduced
speed.
t
he alert is maintained until the system
is reinitialised.
Driving safely
Page 144 of 192

142
Bipper_en_Chap08_verifications_ed02-2014
FILLING WITH FUEL
Capacity of the fuel tank: approximately 45 litres.
Low fuel level
When the minimum fuel tank level
is reached, this warning lamp
comes on. When it first comes on,
you have approximately 6 litres
of fuel remaining. Refuel without delay to
avoid running out of fuel.
An arrow in the instrument panel indicates
which side of the vehicle the filler flap is
located.
Refuelling must be done with the engine off.
-
Open the fuel filler flap.
-
Hold the filler cap with one hand.
-
With the other hand, insert the key
, then
turn it a third of a turn.
-
Remove the filler cap and hang it on the
hook, located on the inside of the filler
flap.
FUEL CUT-OFF
In the event of a serious collision, a device
automatically cuts off the fuel supply to the
engine and the vehicle's electrical supply.
It also automatically unlocks the doors
and switches on of the courtesy lamps. A
message appears in the instrument panel
screen according to version.
turn the key to the
STOP position to prevent
discharging of the battery.
Check that there is no smell or leak of fuel
outside the vehicle.
With Stop & Start, never refuel with the
system in S
t
OP
mode; you must switch
off the ignition with the key. When the fuel filler flap is open, a
safety system prevents sliding of the
side door (Combi).
A label affixed to the inside of the flap
reminds you of the type of fuel to be used.
Opening the filler cap may cause a noise
resulting from the inrush of air.
t
his vacuum
is quite normal and results from the sealing
of the fuel system.
When filling the fuel tank, do not continue
after the 3rd cut-off of the nozzle; this could
cause malfunctions.
After filling the fuel tank, lock the filler cap
and close the flap.
Fuel
Page 145 of 192

143
Bipper_en_Chap08_verifications_ed02-2014
Resetting
to set off again, restore the fuel supply and
the electrical supply manually:
-
with the key in the
STOP position, turn
the key to the RUNNING position,
-
push the direction indicator control stalk
fully upwards,
-
place it in the "Of
f" position,
-
press the direction indicator control stalk
fully downwards,
-
return it to the "Of
f" position,
-
push it fully upwards again,
-
return it to the "Of
f" position,
-
press it fully downwards again,
-
return it to the "Of
f" position,
-
turn the key to the
STOP position.
Fuel used for petrol engines
the petrol engines are compatible with
e
10 bio-petrol (containing 10 % ethanol),
conforming to European standards EN 228
and
e N 15376.
E85 type fuels (containing up to 85 %
ethanol) are reserved exclusively for
vehicles marketed for the use of this type
of fuel (BioFlex vehicles).
t
he quality of
the ethanol must comply with
e uropean
standard EN 15293.
Fuel used for Diesel engines
the Diesel engines are perfectly with
biofuels which conform to current and future
e
uropean standards (Diesel fuel which
complies with standard EN 590 mixed with
a biofuel which complies with standard
e
N 14214) available at the pumps
(containing up to 7 % Fatty Acid Methyl
e
ster).
t
he B30 biofuel can be used in certain
Diesel engines; however, this use is subject
to strict application of the special servicing
conditions indicated in the warranty and
maintenance record. Contact a P
euge O t
dealer or a qualified workshop.
t
he use of any other type of (bio)fuel
(vegetable or animal oils, pure or diluted,
domestic fuel...) is strictly prohibited (risk of
damage to the engine and fuel system).
8
CHECKS
Fuel
Page 173 of 192

171
Bipper_en_Chap09_aide-rapide_ed02-2014
Marking RatingFunctions
F16 7.5 A
e
ngine management control unit - electronic gearbox control unit and gear\
lever -
t
20 relay coil
F17 15 ASupply for ignition coil - injectors - engine management control unit (\
1.3 HDi)
F18 7.5 AEngine management control unit (1.3 HDi) - T09 relay coil
F19 7.5 AAir conditioning compressor
F20 30 ASupply for heated rear screen, electric door mirrors heater elements
F21 15 AFuel pump (1.4 petrol and 1.3 HDi)
F22 20 A
e
ngine management control unit (1.3 HDi)
F23 20 AABS hydraulic block electrovalves supply
F24 7.5 AABS
F30 15 AFoglamps
F81 60 APre-heat unit (1.3 HDi)
F82 30 A
e
lectronic gearbox pump - electronic gearbox supply
F84 10 A
e
lectronic gearbox control unit and electrovalves
F85 30 ACigar lighter - 12 V accessory socket
F87 7.5 A
Reversing lamps - water in Diesel sensor - airflow sensor - T02, T05, T14, T17 and T19 relay coils
(except 1.3 HDi)
5 A Reversing lamps - water in Diesel sensor - airflow sensor - T02, T05, T14, T17 and T19 relay coils -
battery state of charge sensor (except 1.3 HDi)
9
QUICK HELP
Changing a fuse
Page 182 of 192
180
Bipper_en_Chap10_caracteristique_ed02-2014
DIESEL ENGINES1.4 litre HDi 70 hp1.3 litre HDi 75 hp
Gearboxes ManualManualElectronic
g
ears 555
eu
standard maximum power (kW)* 5055
Cubic capacity (cc) 1 3991 248
Bore x stroke (mm) 73.7 x 8269.6 x 82
Max power engine speed (rpm) 4 0003 750
eu
standard max torque (Nm) 160190
Max torque engine speed (rpm) 2 7501 750
Fuel DieselDiesel
Catalytic converter Ye sYe s
Particle emissions filter (PEF) NoYe s
Stop & Start NoYe s
Engine oil capacity with filter replacement (litres) 3.83.0
*
The maximum power corresponds to the value type-approved on a t
est bed, under conditions defined in European legislation (Directive 1999/99/EC).
Engines
Page 183 of 192
181
Bipper_en_Chap10_caracteristique_ed02-2014
PETROL ENGINE1.4 litre 75 hp
Gearbox Manual
g
ears 5
eu
standard maximum power (kW)* 54
Cubic capacity (cc) 1 360
Bore x stroke (mm) 75 x 77
Max power engine speed (rpm) 5 200
eu
standard max torque (Nm) 11 8
Max torque engine speed (rpm) 2 600
Fuel
u
nleaded petrol
Stop & Start No
Engine oil capacity with filter replacement (litres) 3.0
*
The maximum power corresponds to the value type-approved on a t
est bed, under conditions defined in European legislation (Directive 1999/99/EC).
Engines
TECHNICAL DATA
10
Page: