Page 272 of 796
08-31520-00
1. SPECIFICATION
Description Specification
Cooling system Type Water cooling, forced circulation
Coolant Capacity approx. 11.5 L
RadiatorCore size589W x 538H x 27T (over 3,170 cm²)
Flow type Cross flow
AntifreezeType SYC1025 (Long life coolant)
Mixing ratio
(water:antifreeze)50 : 50
Cooling fan moduleMotor type DC motor
Motor weight 2.14 kg
Control type PWM type
Fan runout 3 mm
Coolant reservoirCapacity over 1.5 L
Circulation Closed roof type
Pressure cap Screw type
Pressure 1.4bar
ThermostatType Wax pallet type
Opening temperature90 ℃
Fully open temperature
100℃
Valve lift 8mm
Page 434 of 796

02-38710-01
1. SPECIFICATIONS OF RK - STICS
1) Electrical Performance
2) Chattering of Input Signals
Vehicle speed input:
The vehicle speed calculating time is 1.0 seconds. The elapsed time of 1.5 seconds after IGN
1 switch :ON” is not included.
20 ms target input:
Wiper motor A/S (parking) terminal
100 ms target input switch
All switches except wiper motor A/S (parking) terminal 1.
2.
3.
3) Time Tolerance
If not indicated, time tolerance will be ± 10%.
However, if less than 500 ms, time tolerance will be ± 50 ms.
The time indicated in each function does not include chattering processing time from switch
input changing point. 1.
2.
Item Requirement Remark
Rated voltage DC 12 V
Operating voltage DC 9 to 16 V Should operate normally within this range.
Operating temperature-30℃ ~ +80℃
Reserved temperature-40℃ ~ +85℃
Max. operating humidity 95%
Resistible voltage 24 V
Insulating resistance No heat and fire due to
the current leaks.Confined with PCB, waterproof and coating that
requires the insulation.
Parasitic current below 4.0 mA
(below 6.0 mA)IGN = OFF, Full output load = OFF, 90
seconds (after received the signals), No input
changes for 2 seconds
Voltage drop below 1.2 V
below 2.0 VPin no. 8 and 2, 3, 5, 7, 10, 12, 13, 15, 19, 20,
23, 40, 47, 51, 53, 54
Pin no. 8 and 1, 14
Page 509 of 796
06-98510-00
Center fascia switch
Passenger’s Window Switch
(same with rear window
switches)
Overhead console switch
Auto light sensor
Cigarette lighter
Power outlet socket
Driver’s seat
warmer switch
Rear fog lamp
switchESP OFF switch
Defogger switch
Passenger’s seat
warmer switch Front fog lamp switch
Front room lamp switch
Sunroof switch
Door coupled room lamp switch
Hazard warning
flasher switch
Page 719 of 796
01-14
(2) Rear Air Conditioner Module
Roof air conditioner duct
Blower motor
Evaporator
Mixer door
Heater core
Air mixer door actuator
Rear floor
heater duct
Heater &
air conditioner
pipes
Wiring layout
Components
Rear mode actuator
Rear expansion valve
Rear blower motorHeater valve
Rear blower resistance
Page 780 of 796

04-4
2. CAUTIONS WHEN WORKING
Wear clean work clothes and gloves.
Any unauthorized modification or operational test is not allowed since the sunroof motor and control
unit are preset at the factory.
Pay attention not to drop the sunroof assembly when removing it and do not keep it right up. -
-
-
Even though the sunroof can be operated when the engine is not running, operating the sunroof
repeatedly with the engine turned off will run down the battery. Operate the sunroof while the engine
is running.
When the sunroof operation is completed, release the switch. Keeping pressing the switch can result
in malfunction.
Especially in winter, never operate the sunroof if operation areas are iced. Wait until melted.
To prevent a theft, make sure that the sunroof is completely closed when leaving the vehicle. In
addition, rain or snow can get into the vehicle through the open sunroof.
When the sunroof is fully open, wind buffeting symptom can be worse. In this case, try to adjust the
sunroof position manually or open the sunroof until the wind buffeting is disappeared
Parts of the body can be trapped in the sunroof and can be struck by passing objects. Do not stick
hands, head or anything else out of the openings.
Remove any dirt and foreign material stuck on the edge of the sunroof glass periodically. -
-
-
-
-
-
-
4. MAJOR CHANGES
Sunroof drain rear hose
Sunroof drain rear hose route changed due to rear quarter panel change
3. CAUTIONS FOR OPERATION
Page 781 of 796
04-57340-00
1. OVERVIEW
The sunroof is fitted to the roof panel. It consists of the sunroof switch, sunroof control unit, sunroof
motor, sunroof glass and drain hose.
The sunroof motor is operated by the sunroof control unit according to the operating signal from the
sunroof switch, which results in opening and closing of the sunroof glass.
2. LAYOUT
Sunroof motor
Sunroof control unit
Sunroof switchSunroof assembly
Page 782 of 796
04-6
3. COMPONENTS OF SUNROOF
Sunroof assy
Motor assy-sunroof
Unit-control sunroof
Glass assy-sunroof
Welt-sunroof
Screw
BRKT-sunroof SUPT
Hose-sunroof drain FRT
Grommet-sunroof drain hose FRT 1.
2.
3.
4.
5.
6.
7.
8.
9.Hose-sunroof drain RR
Grommet-sunroof drain hose RR
Cover-sunroof tooling hole
PNL ASSY-sunroof sunshade
Cover-side INR
Cover-side OTR
Wind deflector ASSY-sunroof 10.
11.
12.
14.
15.
16.
17.
Page 783 of 796
04-77340-00
Drain hose Control switch Sun shade & glass
Control unit Sun roof motor
4. COMPONENTS AND LOCATIONS