14-16
3) PM Regeneration of DPF
The differential pressure sensor installed in the DPF measures the pressure values of inlet and outlet of
CDPF. And the amount of the PM collected in the filter is calculated based on the exhaust temperature,
intake air mass flow, booster pressure, etc.
The regeneration is started when the amount of the collected PM is 28 g or more.
The ECU commands post-injection to increase the temperature of CDPF to 600℃.
When the amount of the collected PM is not enough: The DPF works as a filter. 1.
When enough amount of PM is collected: The ECU commands post-injection and increase the
exhaust gas temperature to start regeneration. 2.
01-136810-30
2) Air Conditioner Module Wiring and Layout
(1) Front Air Conditioner Module
Air source selection
door actuator
Air conditioner
filterEvaporator
Blower motor
Blower high
speed relay
Heater core
Wiring layout
Components
Sun sensor
Interior temperature sensor
Front mode actuator
Air mix actuator
Duct temperature sensor
PTC heater A.
B.
C.
D.
E.
F.Thermo amplifier
Front power transistor
Front blower motorA/C filter
Air source mode actuator
Rear blower switch G.
H.
I.
J.
K.
M.