2013 SSANGYONG KORANDO battery

[x] Cancel search: battery

Page 526 of 1336

SSANGYONG KORANDO 2013  Service Manual 1452-01
1. SPECIFICATION
Unit Description Specification
AlternatorType HPS EPS
Crankshaft pulley : Alternator pulley 1 : 2.66
Normal output 
(idle/2200rpm)70/140A
Regulator voltage 12V
BrushLength 12.

Page 528 of 1336

SSANGYONG KORANDO 2013  Service Manual 1452-01
2) Battery
Battery assembly
Clamp - Battery
Bolt
Cable assembly - Cable positive 
Cable assembly - Battery ground 
Bolt - Earth
Cap - Terminal
Connector - Battery 1.
2.
3.
5.
6.
8.
9.
10.Nut
N

Page 529 of 1336

SSANGYONG KORANDO 2013  Service Manual Item How to check DTC set value / Action
Output current
B terminal current
Rotor coil 
resistance
L terminal voltage
3. INSPECTION
1) Alternator
Output Test
Disconnect the cable connected to the B 
te

Page 530 of 1336

SSANGYONG KORANDO 2013  Service Manual 1452-01
Troubleshooting
Item Cause Action
Overcharged batteryDefective alternator voltage regulator Replace
Defective voltage detection wiring Repair or replace
Discharged batteryLoose alternator driv

Page 531 of 1336

SSANGYONG KORANDO 2013  Service Manual 2) Battery
Inspection

Page 532 of 1336

SSANGYONG KORANDO 2013  Service Manual 1452-01
Using battery tester
PASS (11.0 V or more): Explain to the customer that the battery is reusable.
Need to be charged (9.0 to 11.0 V): Charge the battery with a charger and reinstall it. Explai

Page 533 of 1336

SSANGYONG KORANDO 2013  Service Manual Jump start
If the battery is weak or terminated, the battery from another vehicle can be used with jumper cables to 
start the engine.
Connecting order
The positive (+) terminal of the discharged batt

Page 534 of 1336

SSANGYONG KORANDO 2013  Service Manual 1452-01
Maintenance
If the charge warning lamp (      ) on the instrument cluster comes on while driving, there is a malfunction 
in the charge system including the battery. Therefore, carrying out th