Page 677 of 1336
8710-01
The door LOCK/UNLOCK relay is installed inside the actuator.
Page 679 of 1336
8710-01
The door LOCK/UNLOCK relay is installed inside the actuator.
Page 705 of 1336
8710-01
Operating process
The door LOCK/UNLOCK relay is installed inside the actuator.
Page 706 of 1336
Door LOCK/UNLOCK control by central door LOCK switch
The central door LOCK switch is turned ON.
The door LOCK/UNLOCK relay is activated for 0.5 seconds (T1, T2). A.
B. Operation 1.
The central door switch signal is ignored in the theft deterrent mode. C. Operation 2.
When one of the door LOCK detection switches* is in LOCK position with the ignition turned OFF,
all doors are unlocked automatically.
When the central door switch LOCK is operated with all doors unlocked and any door ajar, the door
LOCK relay is activated followed by UNLOCK relay to prevent the door LOCK by misoperation.
* Door LOCK detection switch: The switch is installed inside the door actuator and detects
the door LOCK status. -
-
Central door LOCK switch (driver door side)
Page 707 of 1336
8710-01
Operating process
The door LOCK/UNLOCK relay is installed inside the actuator.
Page 709 of 1336
8710-01
The door LOCK/UNLOCK relay is installed inside the actuator.
Page 710 of 1336
Door LOCK/UNLOCK control by smart key
The SKM receives LOCK signal through B-CAN with IGN OFF or ACC ON.
The BCM outputs LOCK relay signal for 0.5 seconds (T2).
The turn signal lamp is turned ON for 0.5 seconds and then turned OFF for 0.5 seconds, and this
operation is repeated 2 times. A.
B.
C. Operation 1.
SKM receives UNLOCK signal through B-CAN with IGN ON, IGN OFF, or ACC ON.
BCM outputs UNLOCK relay signal for 0.5 seconds (T3).
The turn signal lamp is operated once for 1 second. D.
E.
F. Operation 2.
The door LOCK/UNLOCK relay is installed inside the actuator.
Page 713 of 1336
8710-01
The door LOCK/UNLOCK relay is installed inside the actuator.