17B-19V2 MR-376-X76-17B050$070.mif
PETROL INJECTION
Fault finding – Fault summary table17B
V42 Injection
Program No.: 2A
Vdiag No.: 04, 05, 06,
14, 16, 18
*Refriger: RefrigerantTool fault DTC code Diagnostic tool title
DF8842632 Additional fuel circuit pump relay
DF8870226 Brake - accelerator pedal position
DF8941633 Additional fuel circuit solenoid valve
DF9740225 Pedal potentiometer circuit gang 1
DF9752120 Pedal potentiometer circuit gang 2
DF9921644 Additional heater 1 relay circuit
DF9931645 Additional heater 2 relay circuit
DF9941646 Additional heater 3 relay circuit
DF10150504 Brake switch signal consistency
DF10160833 Clutch switch signal consistency
DF1017061A Computer
DF10340314 Combustion misfire
DF10580106 Inlet pressure consistency
DF1063C415 ESP multiplex connection
DF10680530 Refriger* pressure sensor voltage
DF10720645 Air conditioning compressor relay control
DF10740638 Motorised throttle position inconsistent
17B-145
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
V2 MR-376-X76-17B050$084.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
V42 Injection
Program No.: 2A
Vdiag No.: 04, 05, 06,
14, 16, 18
DF1074
PRESENT OR
STOREDMOTORISED THROTTLE POSITION INCONSISTENT1.DEF: Inconsistency between throttle valve position and control.
2.DEF: Inconsistent signal.
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is considered present under the following conditions:
–For 1.DEF engine running at idle speed.
Special note:
For 1.DEF, the OBD warning light illuminates,
For 2.DEF, the OBD warning light and level 2 fault warning light illuminate.
See the Wiring Diagrams Technical Note for Logan, Sandero, Duster, Thalia 2/
Symbol 2, Clio II F 6, Kangoo VLL.
Check the connection and condition of the motorised throttle valve connector, component code 1076 and the
injection computer connector, component code 120.
If the connector or connectors are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the insulation, continuity and the absence of interference resistance on the following connections:
–3AJB between components 1076 and 120,
–3AJC between components 1076 and 120,
–3MP between components 1076 and 120,
–3MQ between components 1076 and 120,
–3MO between components 1076 and 120.
If the connection or connections are faulty and if there is a repair method (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
If the fault is still present, contact the Techline.
V42_V04_DF1074/V42_V05_DF1074/V42_V06_DF1074/V42_V14_DF1074/V42_V16_DF1074/V42_V18_DF1074