17B-56V2 MR-376-X76-17B050$081.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
V42 Injection
Program No.: 2A
Vdiag No.: 04, 05, 06,
14, 16, 18
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
DF083
PRESENT OR
STOREDDOWNSTREAM OXYGEN SENSOR HEATING CIRCUITCO: Open circuit
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
NOTESSee the Wiring Diagrams Technical Note for Logan, Sandero, Duster, Thalia 2/
Symbol 2, Clio II F 6, Kangoo VLL.
Special notes:
For CO and CC.1, the OBD warning light and level 1 fault warning light illuminate.
Check the condition of the fuse of the supply circuit for the downstream oxygen sensor, component code 242.
If the fuse is faulty, replace the fuse (see MR 388 (Logan and Sandero), MR 451 (Duster), MR 423 (Thalia 2/
Symbol 2), MR 430 (Clio II F 6) or MR 374 (Kangoo VLL), Mechanical, 81C, Fuses, Fuses: List and location
of components).
Check the cleanliness and condition of the injection computer connector, component code 120 and of the
connector of the downstream oxygen sensor, component code 242.
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector(s), otherwise replace the wiring.
With the ignition on, check for + 12 V on connection 3FB of component 242.
Check the insulation, continuity and the absence of interference resistance of the following connection:
–3FB between components 1047 (for Logan, Sandero, Duster) or 238 (for Thalia 2/Symbol 2, Kangoo VLL) or
983 (for Clio II F 6) and 242,
–3GG between components 120 and 242.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
If all the checks are correct, replace the downstream oxygen sensor, component code 242 (see MR 388 (Logan
and Sandero), MR 451 (Duster), MR 423 (Thalia 2/Symbol 2), MR 430 (Clio II F 6) or MR 374 (Kangoo VLL),
Mechanical, 17B, Petrol injection, Oxygen sensors: Removal - Refitting).
If the fault is still present, contact the Techline.
V42_V04_DF083/ V42_V05_DF083/V42_V06_DF083/V42_V14_DF083/V42_V16_DF083/V42_V18_DF083
17B-58V2 MR-376-X76-17B050$081.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
V42 Injection
Program No.: 2A
Vdiag No.: 04, 05, 06,
14, 16, 18
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
DF085
CONTINUED
Check the insulation, continuity and absence of interference resistance on the following connection:
For Logan, Sandero, Duster, Clio II F 6:
–3AC between components 236 (1047) and 120,
–3NA between components 236 (1047) and 833.
For Thalia 2/Symbol 2, Kangoo VLL:
–3AC between components 236 and 120,
–3N between components 236 and 218,
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the power circuit supply at the fuel supply pump relay output with a test light by running command AC015
Fuel pump relay.
If the supply at the relay output is not correct, replace the petrol pump relay, component code 236 (1047) (see MR
388 (Logan and Sandero), MR 451 (Duster), MR 423 (Thalia 2/Symbol 2), MR 430 (Clio II F 6) or MR 374
(Kangoo VLL), Mechanical, 87G, Engine compartment connection unit, Engine compartment connection
unit: List and location of components).
If the fault is still present, contact the Techline.
17B-61
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
V2 MR-376-X76-17B050$082.mif
17B
V42 Injection
Program No.: 2A
Vdiag No.: 04, 05, 06,
14, 16, 18
DF092
PRESENT OR
STOREDUPSTREAM OXYGEN SENSOR CIRCUITCC.1: Short circuit to + 12 V
CO: Open circuit
CC.0: Short circuit to earth
(---)
NOTESDeal with the following faults first:
Only for CC.1 - DF082 Upstream oxygen sensor heating circuit.
Conditions for applying the fault finding procedure to a stored fault:
The fault is declared present:
–CC.0 - engine idling
–CC.1 - engine idling for > 180 seconds
–CO - engine idling
– in the fourth case (---), it is impossible to change the fault to present status, deal with
the stored fault
See the Wiring Diagrams Technical Note for Logan, Sandero, Duster, Thalia 2/
Symbol 2, Clio II F 6, Kangoo VLL.
CO
CC.1
CC.0
NOTESSpecial notes:
level 1 fault warning light illuminated.
Check the cleanliness and condition of the connector of the upstream oxygen sensor, component code 887 and
of the injection computer connector, component code 120.
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair) repair the connector(s); otherwise, replace the wiring.
Check the insulation, continuity and the absence of interference resistance on the following connections:
–3GH between components 120 and 887,
–3GK between components 120 and 887.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
V42_V04_DF092/V42_V05_DF092/V42_V06_DF092/V42_V14_DF092/V42_V16_DF092/V42_V18_DF092
PETROL INJECTION
Fault finding – Interpretation of faults
17B-63V2 MR-376-X76-17B050$082.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
V42 Injection
Program No.: 2A
Vdiag No.: 04, 05, 06,
14, 16, 18
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
DF093
PRESENT OR
STOREDDOWNSTREAM OXYGEN SENSOR CIRCUITCC.1: Short circuit to + 12 V
CO: Open circuit
CC.0: Short circuit to earth
NOTESDeal with the following faults first:
Only for CC.1 and CO - DF083 Downstream oxygen sensor heating circuit.
Conditions for applying the fault finding procedure to a stored fault:
The fault is declared present:
– with the engine idling for > 300 seconds
See the Wiring Diagrams Technical Note for Logan, Sandero, Duster, Thalia 2/
Symbol 2, Clio II F 6, Kangoo VLL.
CC.1
CC.0
NOTESSpecial notes:
Level 1 fault warning light illuminated.
Check the condition of the fuse of the supply circuit for the downstream oxygen sensor, component code 242.
If the fuse is faulty, check all the following steps and replace the fuse (see MR 388 (Logan and Sandero), MR 451
(Duster), MR 423 (Thalia 2/Symbol 2), MR 430 (Clio II F 6) or MR 374 (Kangoo VLL), Mechanical, 81C, Fuses,
Fuses: List and location of components).
Check the cleanliness and condition of the injection computer connector, component code 120 and of the
connector of the downstream oxygen sensor, component code 242.
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector(s), otherwise replace the wiring.
Check the insulation, continuity and the absence of interference resistance on the following connections:
–3GJ between components 120 and 242,
–3GL between components 120 and 242.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, replace the downstream oxygen sensor, component code 242 (see MR 388 (Logan and
Sandero), MR 451 (Duster), MR 423 (Thalia 2/Symbol 2), MR 430 (Clio II F 6) or MR 374 (Kangoo VLL),
Mechanical, 17B, Petrol injection, Oxygen sensors: Removal - Refitting).
If the fault is still present, contact the Techline.
V42_V04_DF093/V42_V05_DF093/V42_V06_DF093/V42_V14_DF093/V42_V16_DF093/V42_V18_DF093
17B-64V2 MR-376-X76-17B050$082.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
V42 Injection
Program No.: 2A
Vdiag No.: 04, 05, 06,
14, 16, 18
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
DF093
CONTINUED
CONOTESNone.
Check the condition of the fuse of the supply circuit for the downstream oxygen sensor, component code 242.
If the fuse is faulty, check all the following steps and replace the fuse (see MR 388 (Logan and Sandero), MR 451
(Duster), MR 423 (Thalia 2/Symbol 2), MR 430 (Clio II F 6) or MR 374 (Kangoo VLL), Mechanical, 81C, Fuses,
Fuses: List and location of components).
Read the stored speed within the context of the fault using PR089 Vehicle speed.
If the value is 0, drive the vehicle to reach a speed of 6 mph (10 km/h) and check PR089 again.
If the value of this parameter is 0 whilst driving, apply the fault finding procedure for DF091 Vehicle speed signal,
abandoning the steps described below. If PR089 operates normally, follow the fault finding procedure for this fault.
Check the cleanliness and condition of the injection computer connector, component code 120 and of the
connector of the downstream oxygen sensor, component code 242.
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector(s), otherwise replace the wiring.
Check the insulation, continuity and the absence of interference resistance on the following connections:
–3GJ between components 120 and 242,
–3GL between components 120 and 242.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
If the fault is still present, replace the downstream oxygen sensor, component code 242 (see MR 388 (Logan and
Sandero), MR 451 (Duster), MR 423 (Thalia 2/Symbol 2), MR 430 (Clio II F 6) or MR 374 (Kangoo VLL),
Mechanical, 17B, Petrol injection, Oxygen sensors: Removal - Refitting).
If the fault is still present, contact the Techline.
17B-65V2 MR-376-X76-17B050$082.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
V42 Injection
Program No.: 2A
Vdiag No.: 04, 05, 06,
14, 16, 18
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
DF095
PRESENT OR
STOREDTHROTTLE POTENTIOMETER CIRCUIT GANG 11.DEF: Signal incoherent
WARNING
Never drive the vehicle without having confirmed that no faults involving the throttle valve are present.
NOTESSpecial notes:
OBD warning light and level 1 fault warning light illuminate,
The throttle no longer operates.
See the Wiring Diagrams Technical Note for Logan, Sandero, Duster, Thalia 2/
Symbol 2, Clio II F 6, Kangoo VLL.
Check the cleanliness of the throttle valve, component code 1076 and that the throttle rotates properly (no
resistance point)
Check the cleanliness and condition of the throttle valve connector.
If the connector is faulty and there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the cleanliness and condition of the injection computer connector, component code 120.
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector(s), otherwise replace the wiring.
Check the insulation, continuity and the absence of interference resistance on the following connections:
–3MO between components 120 and 1076,
–3MP between components 120 and 1076,
–3MN between components 120 and 1076.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the throttle valve has been replaced, reinitialise the programming by running command RZ031 Throttle stop
programming.
If the fault is still present, contact Techline.
V42_V04_DF095/V42_V05_DF095/V42_V06_DF095/V42_V14_DF095/V42_V16_DF095/V42_V18_DF095
17B-66V2 MR-376-X76-17B050$082.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
V42 Injection
Program No.: 2A
Vdiag No.: 04, 05, 06,
14, 16, 18
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
DF096
PRESENT OR
STOREDTHROTTLE POSITION POTENTIOMETER CIRCUIT GANG 21.DEF: Signal incoherent
WARNING
Never drive the vehicle without having confirmed that no faults involving the throttle valve are present.
NOTESDeal with the following faults first:
DF011 Sensor supply voltage no. 1.
Special notes:
OBD warning light and level 1 fault warning light illuminate,
The throttle no longer operates
See the Wiring Diagrams Technical Note for Logan, Sandero, Duster, Thalia 2/
Symbol 2, Clio II F 6, Kangoo VLL.
Check the cleanliness of the throttle valve, component code 1076 and that the throttle rotates properly (no
resistance point).
Check the cleanliness and condition of the injection computer connector, component code 120 and of the throttle
valve connector, component code 1076.
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector(s), otherwise replace the wiring.
Check the insulation, continuity and the absence of interference resistance on the following connections:
–3MQ between components 120 and 1076,
–3MN between components 120 and 1076,
–3MO between components 120 and 1076.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the throttle valve has been replaced, reinitialise the programming by running command RZ031 Throttle stop
programming.
If the fault is still present, contact Techline.
V42_V04_DF096/V42_V05_DF096/V42_V06_DF096/V42_V14_DF096/V42_V16_DF096/V42_V18_DF096
17B-67V2 MR-376-X76-17B050$082.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
V42 Injection
Program No.: 2A
Vdiag No.: 04, 05, 06,
14, 16, 18
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
DF101
PRESENT OR
STOREDMULTIPLEX ELECTRONIC STABILITY PROGRAM LINK1.DEF: Invalid multiplex signals generated by computer
NOTESNone
Test the ABS computer (see38C, Anti-lock braking system).
V42_V04_DF101/V42_V05_DF0101/V42_V06_DF101/V42_V14_DF101/V42_V16_DF101/V42_V18_DF101