17B-127
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
V2 MR-376-X76-17B050$084.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
V42 Injection
Program No.: 2A
Vdiag No.: 04, 05, 06,
14, 16, 18
DF894
CONTINUED 1
For engines: F4R 404, 405, 408
NOTESThis fault corresponds to an electrical fault of the additional fuel circuit injector, which is
fitted directly on the throttle valve. It is not a solenoid valve fault.
See the Wiring Diagrams Technical Note for Duster.
Check the fitting and sealing of the additional fuel circuit injector
If there is leakage, replace the defective component (the injector inlet hose, the injector seal, the additional fuel
circuit injector).
Check the connection and condition of the connector of the additional fuel circuit injector, component code 1640
and the injection computer connector, component code 120.
If the connector or connectors are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the continuity, insulation and the absence of interference resistance on the following connections:
–3ACM between components 1640 and 120,
–3FB between components 1640 and 1047.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
17B-128
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
V2 MR-376-X76-17B050$084.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
V42 Injection
Program No.: 2A
Vdiag No.: 04, 05, 06,
14, 16, 18
DF894
CONTINUED 2
Check the supply of the additional fuel circuit injector using a multimeter in the voltmeter position (direct current
mode).
Run command AC217 Additional fuel circuit solenoid valve and check that the average voltage reading is
different from 0 V.
Check the internal resistance of the additional fuel circuit injector, component code 1640 on the computer
connector. Its value must be between: 13.775 X 15.225 or 24 X 30 (F4R engine on Duster) at
20ºC. If the resistance is incorrect, replace the injector.
If the fault is still present, contact the Techline.
17B-129
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
V2 MR-376-X76-17B050$084.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
V42 Injection
Program No.: 2A
Vdiag No.: 04, 05, 06,
14, 16, 18
DF974
PRESENT OR
STOREDPEDAL POTENTIOMETER CIRCUIT GANG 11.DEF: Battery voltage too high.
2.DEF: Battery voltage too low.
NOTESFault priorities:
Deal with the following fault as a priority:
DF011 Sensor voltage supply no. 1
Special notes:
After this fault appears:
The OBD and level 1 warning lights are illuminated.
See the Wiring Diagrams Technical Note for Logan, Sandero, Duster, Thalia 2/
Symbol 2, Clio II F 6, Kangoo VLL.
Check the connection and condition of the connector of the accelerator pedal sensor, gang 1, component code
921 and of the injection computer connector, component code 120.
If the connector or connectors are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Run TEST 8 Accelerator pedal potentiometer check.
If the fault is still present, contact the Techline.
V42_V04_DF974/V42_V05_DF974/V42_V06_DF974/V42_V14_DF974/V42_V16_DF974/V42_V18_DF974
17B-130
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
V2 MR-376-X76-17B050$084.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
V42 Injection
Program No.: 2A
Vdiag No.: 04, 05, 06,
14, 16, 18
DF975
PRESENT OR
STOREDPEDAL POTENTIOMETER CIRCUIT GANG 21.DEF: Battery voltage too high.
2.DEF: Battery voltage too low.
NOTESSpecial notes:
After this fault appears:
The OBD and level 1 warning lights are illuminated.
See the Wiring Diagrams Technical Note for Logan, Sandero, Duster, Thalia 2/
Symbol 2, Clio II F 6, Kangoo VLL.
Check the connection and condition of the connector of the accelerator pedal sensor, gang 2, component code
921 and of the injection computer connector, component code 120.
If the connector or connectors are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Run TEST 8 Accelerator pedal potentiometer check.
If the fault is still present, contact the Techline.
V42_V04_DF975/V42_V05_DF975/V42_V06_DF975/V42_V14_DF975/V42_V16_DF975/V42_V18_DF975
17B-131
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
V2 MR-376-X76-17B050$084.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
V42 Injection
Program No.: 2A
Vdiag No.: 04, 05, 06,
14, 16, 18
DF992
PRESENT OR
STOREDADDITIONAL HEATER 1 RELAY CIRCUITCC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
CO: Open circuit
NOTESSee the Wiring Diagrams Technical Note for Logan, Sandero, Duster.
Check the cleanliness and condition of the additional heater 1 relay, component code 1067 and the connections
of the injection computer, component code 120.
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector(s), otherwise replace the wiring.
Check the insulation, continuity and absence of interference resistance on the following connection:
–38JU between components 1067 and 120,
–3FB between components 1067 and 1047.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check that the additional heater relay operates correctly by running command AC250 Heating resistor 1 relay
and check that there are no more faults on the relay. If the check is not correct, replace the additional heater relay,
component code 1067 (see MR 388 or 451, Mechanical, 61A, Heating system, Heating resistor relay:
Removal - Refitting).
If the fault is still present, contact the Techline.
V42_V04_DF992/V42_V05_DF992/V42_V06_DF992/V42_V14_DF992/V42_V16_DF992/V42_V18_DF992
17B-132
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
V2 MR-376-X76-17B050$084.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
V42 Injection
Program No.: 2A
Vdiag No.: 04, 05, 06,
14, 16, 18
DF993
PRESENT OR
STOREDADDITIONAL HEATER 2 RELAY CIRCUITCC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
CO: Open circuit
NOTESSee the Wiring Diagrams Technical Note for Logan, Sandero, Duster.
Check the cleanliness and condition of the additional heater 2 relay, component code 1068 and the connections
of the injection computer, component code 120.
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector(s), otherwise replace the wiring.
Check the insulation, continuity and absence of interference resistance on the following connection:
–38JV between components 1068 and 120,
–3FB between components 1068 and 1047.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check that the additional heater relay operates correctly by running command AC251 Heating resistor 2 relay
and check that there are no more faults on the relay. If the check is not correct, replace the additional heater relay,
component code 1068 (see MR 388 or 451, Mechanical, 61A, Heating system, Heating resistor relay:
Removal - Refitting).
If the fault is still present, contact the Techline.
V42_V04_DF993/V42_V05_DF993/V42_V06_DF993/V42_V14_DF993/V42_V16_DF993/V42_V18_DF993
17B-133
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
V2 MR-376-X76-17B050$084.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
V42 Injection
Program No.: 2A
Vdiag No.: 04, 05, 06,
14, 16, 18
DF994
PRESENT OR
STOREDADDITIONAL HEATER 3 RELAY CIRCUITCC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
CO: Open circuit
NOTESSee the Wiring Diagrams Technical Note for Logan, Sandero, Duster.
Check the cleanliness and condition of the additional heater 3 relay, component code 1069 and the connections
of the injection computer, component code 120.
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector(s), otherwise replace the wiring.
Check the insulation, continuity and absence of interference resistance on the following connection:
–38JW between components 1069 and 120,
–3FB between components 1069 and 1047.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check that the additional heater relay operates correctly by running command AC252 Heating resistor 3 relay
and check that there are no more faults on the relay. If the check is not correct, replace the additional heater relay,
component code 1069 (see MR 388 or 451, Mechanical, 61A, Heating system, Heating resistor relay:
Removal - Refitting).
If the fault is still present, contact the Techline.
V42_V04_DF994/V42_V05_DF994/V42_V06_DF994/V42_V14_DF994/V42_V16_DF994/V42_V18_DF994
17B-134
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
V2 MR-376-X76-17B050$084.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
V42 Injection
Program No.: 2A
Vdiag No.: 04, 05, 06,
14, 16, 18
DF1015
PRESENT OR
STOREDBRAKE SWITCH SIGNAL CONSISTENCY
1.DEF: Value outside permitted tolerance values
2.DEF: Inconsistent signal.
NOTESFault priorities
Deal with the following faults first:
DF050 Brake switch circuit
DF631 Brake light switch signal
Conditions for application to a stored fault:
The fault is declared present:
–For 1.DEF engine at idle speed.
–For 2.DEF, if impossible to see the fault present, deal with it as stored.
See the Wiring Diagrams Technical Note for Logan, Sandero, Duster, Thalia 2/
Symbol 2, Clio II F 6, Kangoo VLL.
With the brake pedal released, check ET039 Brake pedal and ET799 Brake wire contact.
If ET039 is Released and ET799 is Inactive.
Check the fitting and mechanical operation of the brake pedal (the pedal returns properly).
If the check is incorrect, check the braking system.
Remove the brake pedal switch, component code 160 (see MR 388 (Logan and Sandero), MR 451 (Duster),
MR 423 (Thalia 2/Symbol 2), Mechanical, 37A, Mechanical component controls, Brake pedal switch:
Removal - Refitting or MR 430 (Clio II F 6), MR 374 (Kangoo VLL), Mechanical, 37A, Mechanical component
controls, Brake pedal: Removal - Refitting) and, without depressing the pedal, press sufficiently on the brake
pedal switch to seat it completely in its position.
Lock it by turning it an eighth of a turn.
The fault should change from present to stored.
V42_V04_DF1015/V42_V05_DF1015/V42_V06_DF1015/V42_V14_DF1015/V42_V16_DF1015/V42_V18_DF1015