82D-23V1 MR-376-X76-82D000$090.mif
82D
UCH
Vdiag No.: 0F
NOTESOnly check conformity after a complete check with the diagnostic tool.
The values indicated in this conformity check are given as examples.
Application conditions: engine stopped, ignition on.
FunctionParameter or Status
Check or ActionDisplay and notes Fault finding
ImmobiliserET127:Immobiliser
warning lightOFFIn the event of a fault, apply
the interpretation of status
ET127 (see 87B, UCH).
ET184:Valid key codeYES when the ignition is
switched onIn the event of a fault, apply
the interpretation of status
ET184.
ET185:Key code
receivedYES when the ignition is
switched onIn the event of a fault, apply
the interpretation of status
ET185.
ET549:Immobiliser activeNOIn the event of a fault, apply
the interpretation of status
ET549.
KeyPR056:Number of keys
allocated2 keys on leaving the
factory and programming of
up to 4 keys in After-SalesIn the event of a fault, apply
the interpretation of parameter
PR056.
ET183:Key already
programmed for
the vehicleYESIn the event of a fault, apply
the scenario SC015 Key
allocation
DoorsET489:Front doorsOpen when opening a front
door.In the event of a fault, apply
the interpretation of status
ET489 (see 87B, UCH).
ET551:Rear doors or
bootOpen when opening a rear
door or the luggage
compartment lid.In the event of a fault, apply
the interpretation of status
ET551 (see 87B, UCH).
UCH_V0F_CCONF
ACCESS - SECURITY
Fault finding – Conformity check
82D-38
AFTER REPAIRCarry out a complete check with the diagnostic tool.
V1 MR-376-X76-82D000$170.mif
82D
UCH
Vdiag No.: 0F
ALP 7 The vehicle will not start
NOTESOnly refer to the customer complaints after performing a complete check using
the diagnostic tool.
Does the central locking operate?See 87B, Passenger compartment
connection unit.
Switch on the ignition. Has the immobiliser
warning light gone out?
Turn the starter.
Nothing happens.The starter clicks
but the engine
does not turn over.The starter motor
turns but there is
no engagement.The engine turns
but does not start.The engine turns
over progressively
more slowly and
does not start.
Perform an
injection domain
test using the
diagnostic tool.
See 13B, Diesel
Injection or 17B,
Petrol Injection.Check the battery
voltage. Check the
condition of the
starter.
NO
YES
NOA
YES
BCD
UCH_V0F_ALP07
ACCESS - SECURITY
Fault finding – Fault finding chart