SSANGYONG NEW REXTON 2012  Service Manual 0000-00
4. GUIDELINES ON ENGINE SERVICE
To prevent personal injuries and vehicle damages that can be caused by mistakes during engine and 
unit inspection/repair and to secure optimum engine performan

Page 285 of 600

SSANGYONG NEW REXTON 2012  Service Manual Brake booster and naster 
cylinderVacuum pump
Pump capacity: 210 cc/rev
Camshaft speed: 375 to 3,000 rpm
Lubrication temperature: -40 to 
Oil: 5W30
Drive type: Driven by exhaust 
Camshaft sprocket
2.

Page 333 of 600

SSANGYONG NEW REXTON 2012  Service Manual 2210-01
2) Cleanness
(1) Cleanness of DI engine fuel system
Cleanness of DI engine fuel system and service procedures
The fuel system for DI engine consists of transfer (low pressure) line and high pr

Page 334 of 600

SSANGYONG NEW REXTON 2012  Service Manual (2) Di engine and its expected problems and remedies can be caused by 
     water in fuel
System supplement against paraffin separation
In case of Diesel fuel, paraffin, one of the elements, can be se

Page 335 of 600

SSANGYONG NEW REXTON 2012  Service Manual 2210-01
1. OVERVIEW
The components in fuel system supply the fuel and generate the high pressure to inject the fuel to each 
injector. They are controlled by the engine ECU.
The common rail fuel injec

Page 336 of 600

SSANGYONG NEW REXTON 2012  Service Manual Fuel tank
Fuel metering by sender
2. SYSTEM LAYOUT AND OPERATION
1) Layout
For sensor and actuator control logic, refer to Chapter "Engine Control".
Engine ECU (D20DTR)
Engine control by vario

Page 340 of 600

SSANGYONG NEW REXTON 2012  Service Manual The engine ECU calculates the accelerator pedal based on the input signals from various sensors, and 
controls the overall operation of the vehicle.
The ECU receives the signals from various sensor th

Page 368 of 600

SSANGYONG NEW REXTON 2012  Service Manual 1914-01
1. SYSTEM DESCRIPTION OF E-VGT 
    (Electric-Variable Geometry Turbine)
The E-VGT turbocharger has one shaft where at each ends are installed with two turbines having 
different angles to con